Secondary Underground Distribution Aluminium Cable
Single conductors are UL Listed as Type USE-2.
- Excellent heat, ozone, oil and chemical resistance.
- Resistant to tear and abrasion. Suitable for direct burial.
Product Description
Secondary URD aluminum
Features
Single conductors are UL Listed as Type USE-2.
Excellent heat, ozone, oil and chemical resistance.
Resistant to tear and abrasion. Suitable for direct burial.
AA-8000 Series aluminum alloy conductor where increased
flexibility is required.
Application
Used for secondary distribution and underground service at 600 V or less.
May be used in ducts or direct burial.
Standards
ICEA S-105-692
600 V Single Layer Thermoset Insulated Utility Underground Distribution Cable.
UL 854
Service-Entrance Cables.
Specifications
Maximum operating voltage:
• 600 V
1
2
3
Maximum conductor operation temperatures:
• 90 °C wet and dry
Engineering Information
1. Conductor: Aluminum alloy
S IN GL E
1350-H19, compressed Class B stranding, or unilay-compressed per ASTM B231.
| Parameter | Specification |
|---|---|
| Conductor Phase ID | Ink printed. Configurations |
| Single | One black phase insulated conductor. |
| Duplex | One black phase |
insulated conductor and one neutral insulated conductor cabled together.
Triplex: Two black phase
insulated conductors (A & B) and one neutral insulated conductor cabled together.
Quadruplex: Three black phase insulated conductors (A, B & C) and one neutral insulated
conductor cabled together.
On request, AA-8000 series
aluminum alloy per ASTM B800 and B801 or copper conductors.
2. Separator: A suitable opaque tape, as required.
D U P L EX
3. Insulation:
Phase conductor: Black thermoset cross-linked polyethylene (XLPE).
Neutral conductor: Black
thermoset cross-linked
polyethylene (XLPE), with three yellow extruded stripes.
TR I P L E X
Q U A DRUP L E X
Secocon ady URD Cable – lumnnu
Secondary URD aluminum, XLPE insulated, 600 V
Single
CodeWord |
Phase Conductor |
XLPE Insulation |
||||
SizeAWG orkcmil |
NumberofStrands |
InsulationThicknessmil |
Cable ODmil |
CodeWordSuffix |
Net Weightlb/kft |
|
|
Princeton |
6 |
7 |
60 |
0.31 |
/XLP |
45 |
|
Mercer |
4 |
7 |
60 |
0.35 |
/XLP |
65 |
|
Clemson |
2 |
7 |
60 |
0.41 |
/XLP |
94 |
|
Kenyon |
1 |
19 |
80 |
0.49 |
/XLP |
125 |
|
Harvard |
1/0 |
19 |
80 |
0.53 |
/XLP |
150 |
|
Yale |
2/0 |
19 |
80 |
0.57 |
/XLP |
182 |
|
Tufts |
3/0 |
19 |
80 |
0.62 |
/XLP |
221 |
|
Beloit |
4/0 |
19 |
80 |
0.68 |
/XLP |
271 |
|
Hofstra |
250 |
37 |
95 |
0.76 |
/XLP |
323 |
|
Gonzaga |
300 |
37 |
95 |
0.81 |
/XLP |
377 |
|
Rutgers |
350 |
37 |
95 |
0.86 |
/XLP |
431 |
|
Dartmouth |
400 |
37 |
95 |
0.91 |
/XLP |
485 |
|
Brown |
450 |
37 |
95 |
0.95 |
/XLP |
539 |
|
Emory |
500 |
37 |
95 |
0.99 |
/XLP |
592 |
|
Duke |
600 |
61 |
110 |
1.10 |
/XLP |
711 |
|
Furman |
700 |
61 |
110 |
1.17 |
/XLP |
816 |
|
Sewanee |
750 |
61 |
110 |
1.20 |
/XLP |
870 |
|
Fordham |
1000 |
61 |
110 |
1.35 |
/XLP |
1129 |
The above data are approximate and subject to normal manufacturing tolerances. Other sizes are available upon request. Ampacities: Refer to the beginning of the section.
Duplex
CodeWord |
Phase Conductor |
Neutral Conductor |
Cable OD |
XLPE Insulation |
||||||||
SizeAWG orkcmil |
NumberofStrands |
InsulationThicknessmils |
SizeAWG orkcmil |
NumberofStrands |
InsulationThicknessmil |
SinglePhasein |
CompleteCablein |
CodeWordSuffix |
Net Weight |
|||
lb/kft |
||||||||||||
|
Alcorn |
8 |
1 |
60 |
8 |
1 |
60 |
0.25 |
0.50 |
/XLP/EYS |
62.2 |
||
|
Claflin |
6 |
7 |
60 |
6 |
7 |
60 |
0.31 |
0.61 |
/XLP/EYS |
92.8 |
||
|
Delgado |
4 |
7 |
60 |
4 |
7 |
60 |
0.35 |
0.70 |
/XLP/EYS |
131.7 |
||
|
Cedarcrest |
2 |
7 |
60 |
4 |
7 |
60 |
0.41 |
0.82 |
/XLP/EYS |
161.4 |
||
|
Everett |
2 |
7 |
60 |
2 |
7 |
60 |
0.41 |
0.82 |
/XLP/EYS |
191.2 |
||
|
Findlay |
2/0 |
19 |
80 |
2/0 |
19 |
80 |
0.57 |
1.15 |
/XLP/EYS |
372.0 |
||
|
Hanover |
4/0 |
19 |
80 |
4/0 |
19 |
80 |
0.68 |
1.36 |
/XLP/EYS |
552.1 |
||
|
Glenville |
350 |
37 |
95 |
350 |
37 |
95 |
0.86 |
1.72 |
/XLP/EYS |
880.2 |
||
|
The above data are approximate and subject to normal manufacturing tolerances. Other sizes available upon request. Ampacities: Refer to beginning of section. |
||||||||||||
Secondary URD aluminum, XLPE Insulated, 600 V
Technical Data continued
Triplex
CodeWord |
Phase Conductor |
Neutral Conductor |
Cable OD |
XLPE Insulation |
||||||
SizeAWG orkcmil |
NumberofStrands |
InsulationThicknessmil |
SizeAWG orkcmil |
NumberofStrands |
InsulationThicknessmil |
SinglePhasein |
Complete Cablein |
CodeWordSuffix |
Net Weight |
|
lb/kft |
||||||||||
|
Erskine |
6 |
7 |
60 |
6 |
7 |
60 |
0.31 |
0.66 |
/XLP/EYS |
139 |
|
Vassar |
4 |
7 |
60 |
4 |
7 |
60 |
0.35 |
0.76 |
/XLP/EYS |
198 |
|
Stephens |
2 |
7 |
60 |
4 |
7 |
60 |
0.41 |
0.88 |
/XLP/EYS |
257 |
|
Ramapo |
2 |
7 |
60 |
2 |
7 |
60 |
0.41 |
0.88 |
/XLP/EYS |
287 |
|
Grossmont |
1 |
19 |
80 |
1 |
19 |
80 |
0.49 |
1.06 |
/XLP/EYS |
383 |
|
Brenau |
1/0 |
19 |
80 |
2 |
7 |
60 |
0.53 |
1.14 |
/XLP/EYS |
402 |
|
Bergen |
1/0 |
19 |
80 |
1/0 |
19 |
80 |
0.53 |
1.14 |
/XLP/EYS |
460 |
|
Fisk |
2/0 |
19 |
80 |
2 |
7 |
60 |
0.57 |
1.24 |
/XLP/EYS |
468 |
|
Converse |
2/0 |
19 |
80 |
1 |
19 |
80 |
0.57 |
1.24 |
/XLP/EYS |
500 |
|
Shaw |
2/0 |
19 |
80 |
1/0 |
19 |
80 |
0.57 |
1.24 |
/XLP/EYS |
525 |
|
Hunter |
2/0 |
19 |
80 |
2/0 |
19 |
80 |
0.57 |
1.24 |
/XLP/EYS |
558 |
|
Calvert |
3/0 |
19 |
80 |
2 |
7 |
60 |
0.62 |
1.34 |
/XLP/EYS |
547 |
|
Chase |
3/0 |
19 |
80 |
1 |
19 |
80 |
0.62 |
1.34 |
/XLP/EYS |
579 |
|
Hollins |
3/0 |
19 |
80 |
1/0 |
19 |
80 |
0.62 |
1.34 |
/XLP/EYS |
605 |
|
Rockland |
3/0 |
19 |
80 |
3/0 |
19 |
80 |
0.62 |
1.34 |
/XLP/EYS |
677 |
|
Coburn |
4/0 |
19 |
80 |
1 |
19 |
80 |
0.68 |
1.47 |
/XLP/EYS |
680 |
|
Molloy |
4/0 |
19 |
80 |
1/0 |
19 |
80 |
0.68 |
1.47 |
/XLP/EYS |
705 |
|
Sweetbriar |
4/0 |
19 |
80 |
2/0 |
19 |
80 |
0.68 |
1.47 |
/XLP/EYS |
738 |
|
Monmouth |
4/0 |
19 |
80 |
4/0 |
19 |
80 |
0.68 |
1.47 |
/XLP/EYS |
828 |
|
Aquinas |
250 |
37 |
95 |
2/0 |
19 |
80 |
0.76 |
1.63 |
/XLP/EYS |
844 |
|
Pratt |
250 |
37 |
95 |
3/0 |
19 |
80 |
0.76 |
1.63 |
/XLP/EYS |
884 |
|
Yeshiva |
250 |
37 |
95 |
250 |
37 |
95 |
0.76 |
1.63 |
/XLP/EYS |
987 |
|
Allen |
300 |
37 |
95 |
2/0 |
19 |
80 |
0.81 |
1.75 |
/XLP/EYS |
956 |
|
Greenville |
350 |
37 |
95 |
1/0 |
19 |
80 |
0.86 |
1.85 |
/XLP/EYS |
1034 |
|
Gloucester |
350 |
37 |
95 |
3/0 |
19 |
80 |
0.86 |
1.85 |
/XLP/EYS |
1106 |
|
Wesleyan |
350 |
37 |
95 |
4/0 |
19 |
80 |
0.86 |
1.85 |
/XLP/EYS |
1156 |
|
Newark |
350 |
37 |
95 |
350 |
37 |
95 |
0.86 |
1.85 |
/XLP/EYS |
1320 |
|
Old Dominion |
500 |
37 |
95 |
4/0 |
19 |
80 |
0.99 |
2.13 |
/XLP/EYS |
1483 |
|
Holyoke |
500 |
37 |
95 |
300 |
37 |
95 |
0.99 |
2.13 |
/XLP/EYS |
1592 |
|
Rider |
500 |
37 |
95 |
350 |
37 |
95 |
0.99 |
2.13 |
/XLP/EYS |
1647 |
|
Westchester |
500 |
37 |
95 |
500 |
37 |
95 |
0.99 |
2.13 |
/XLP/EYS |
1811 |
|
Villanova |
750 |
61 |
110 |
350 |
37 |
95 |
1.20 |
2.58 |
/XLP/EYS |
2215 |
|
Voorhees |
750 |
61 |
110 |
450 |
37 |
95 |
1.20 |
2.58 |
/XLP/EYS |
2324 |
|
Fairfield |
750 |
61 |
110 |
500 |
37 |
95 |
1.20 |
2.58 |
/XLP/EYS |
2379 |
|
Seton Hall |
750 |
61 |
110 |
750 |
61 |
110 |
1.20 |
2.58 |
/XLP/EYS |
2662 |
The above data are approximate and subject to normal manufacturing tolerances. Other sizes are available upon request.
Ampacities: Refer to the beginning of the section.
Secondary URD aluminum, XLPE Insulated, 600 V
Quadruplex
CodeWord |
Phase Conductor |
Neutral Conductor |
Cable OD |
XLPE Insulation |
||||||
SizeAWG orkcmil |
NumberofStrands |
InsulationThicknessmil |
SizeAWG orkcmil |
NumberofStrands |
InsulationThicknessmil |
SinglePhasein |
CompleteCablein |
CodeWordSuffix |
Net Weight |
|
lb/kft |
||||||||||
|
Tulsa |
4 |
7 |
60 |
4 |
7 |
60 |
0.35 |
0.85 |
/XLP/EYS |
263 |
|
Miami |
2 |
7 |
60 |
6 |
7 |
60 |
0.41 |
0.99 |
/XLP/EYS |
333 |
|
Dyke |
2 |
7 |
60 |
4 |
7 |
60 |
0.41 |
0.99 |
/XLP/EYS |
353 |
|
Wittenberg |
2 |
7 |
60 |
2 |
7 |
60 |
0.41 |
0.99 |
/XLP/EYS |
382 |
|
Notre Dame |
1/0 |
19 |
80 |
2 |
7 |
60 |
0.53 |
1.28 |
/XLP/EYS |
556 |
|
Purdue |
1/0 |
19 |
80 |
1/0 |
19 |
80 |
0.53 |
1.28 |
/XLP/EYS |
614 |
|
Syracuse |
2/0 |
19 |
80 |
1 |
19 |
80 |
0.57 |
1.39 |
/XLP/EYS |
686 |
|
Lafayette |
2/0 |
19 |
80 |
2/0 |
19 |
80 |
0.57 |
1.39 |
/XLP/EYS |
744 |
|
Swarthmore |
3/0 |
19 |
80 |
1/0 |
19 |
80 |
0.62 |
1.51 |
/XLP/EYS |
831 |
|
Davidson |
3/0 |
19 |
80 |
3/0 |
19 |
80 |
0.62 |
1.51 |
/XLP/EYS |
903 |
|
McPherson |
4/0 |
19 |
80 |
2 |
7 |
60 |
0.68 |
1.64 |
/XLP/EYS |
924 |
|
Doane |
4/0 |
19 |
80 |
1/0 |
19 |
80 |
0.68 |
1.64 |
/XLP/EYS |
981 |
|
Wake Forest |
4/0 |
19 |
80 |
2/0 |
19 |
80 |
0.68 |
1.64 |
/XLP/EYS |
1014 |
|
Earlham |
4/0 |
19 |
80 |
4/0 |
19 |
80 |
0.68 |
1.64 |
/XLP/EYS |
1104 |
|
Rust |
250 |
37 |
95 |
3/0 |
19 |
80 |
0.76 |
1.83 |
/XLP/EYS |
1213 |
|
Palomar |
250 |
37 |
95 |
250 |
37 |
95 |
0.76 |
1.83 |
/XLP/EYS |
1316 |
|
Slippery Rock |
350 |
37 |
95 |
4/0 |
19 |
80 |
0.86 |
2.08 |
/XLP/EYS |
1596 |
|
Niagara |
350 |
37 |
95 |
350 |
37 |
95 |
0.86 |
2.08 |
/XLP/EYS |
1760 |
|
Morehouse |
500 |
37 |
95 |
300 |
37 |
95 |
0.99 |
2.39 |
/XLP/EYS |
2196 |
|
Wofford |
500 |
37 |
95 |
350 |
37 |
95 |
0.99 |
2.39 |
/XLP/EYS |
2251 |
|
Marshall |
500 |
37 |
95 |
500 |
37 |
95 |
0.99 |
2.39 |
/XLP/EYS |
2415 |
|
Westminster |
750 |
61 |
110 |
350 |
37 |
95 |
1.20 |
2.89 |
/XLP/EYS |
3102 |
|
Windham |
750 |
61 |
110 |
500 |
37 |
95 |
1.20 |
2.89 |
/XLP/EYS |
3266 |
|
Tabor |
750 |
61 |
110 |
750 |
61 |
110 |
1.20 |
2.89 |
/XLP/EYS |
3550 |
The above data are approximate and subject to normal manufacturing tolerances. Other sizes are available upon request.
Ampacities: Refer to the the beginning of the the section.
Certificate Display
Type and routine tests are issued from our own testing centre under the ISO 9001 quality system — test reports and certificates accompany every shipment.
Factory Tour
Why Choose Us
Packing & Shipping
- Wooden, steel or steel-wood drums; drum length to customer requirement
- Drum marking per customer / utility specification
- Both drum ends sealed and protected for sea freight
Ready for Your Next Cable Project?
Send us your specifications, cable schedule or RFQ — our engineering team replies with a technical proposal and price within one working day.
- Emailinfo@qzcablegroup.com
- WhatsApp / WeChat+86 173 3570 4553
- Contact personChloe · Export Department
- Factory addressWest Industrial Park, Zhulin Town, Gongyi City, Henan Province, China
Related products
Related solutions
Power Generation Cable Solutions
QZ Cable supplies power generation cable solutions for thermal, hydro, solar and wind power projects, including LV/MV power cables, control cables, instrumentation cables and overhead conductors.
Power Transmission Cable Solutions
QZ Cable supplies power transmission solutions, including AAC, AAAC, ACSR, ACSS, TACSR, TAAAC, OPGW and ADSS for utility, grid expansion and EPC projects worldwide.
Power Distribution Cable Solutions
Qingzhou Cable provides low- and medium-voltage cable solutions for electrical distribution networks, supporting power delivery from substations to commercial, industrial and residential users.
Power Substation Cable Solutions
Solar & Renewable Energy Cable Solutions