One-stop Solution for Wire & Cable · Since 1969
Offshore & Marine Cables

BS — Standard

MV Fire Resistant Power & Control Cables

  • Conductor : Tinned copper wire stranded circular cl.

Product Description

Application and Description

These fire resistant medium voltage elastomeric insulated cables are designed for fixed wiring in ships and on mobile offshore units, suitable for use in power and control applications where fire integrity is essential.

Standards

  • BS 7917
  • IEC 60331-31 Fire resistant
  • IEC 60332-3A Flame retardant
  • IEC 60754-1; IEC 60754-2 Corrosivity
  • IEC 61034-2 Smoke density

Cold bend and impact (-40°C) (on request)

CSA C22.2 No. 38-95 (on request)

Construction

ParameterSpecification
ConductorTinned copper wire stranded circular cl. 2 BS 6360/IEC 60228.
InsulationMica tape + HF-EPR GP5 according to BS 7655 1.2.
Inner SheathHalogen free thermosetting compound SB1 according to BS 7917.
ArmourGalvanized steel wire braid or tinned bronze wire braid (single core).
Outer SheathHalogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6.

Mechanical and Thermal Properties

Minimum Internal Bending Radius : 6×OD

Temperature Range : -40℃ ~ +90℃

Dimensions and Weight

1.9/3.3kV

Construction No. of cores×Cross section Nominal Insulation Thickness Nominal Inner Sheath Thickness Minimum Diameter Over Inner Sheath Maximum Diameter Over Inner Sheath Nominal Armour Wire Diameter Nominal Outer Sheath Thickness Minimum Overall Diameter Maximum Overall Diameter Approx. Weight
mm² mm mm mm mm mm mm mm mm kg/km
1×25 2.2 1.2 13.4 15.2 0.3 1.4 17.5 19.9 687
1×35 2.2 1.3 14.4 16.4 0.3 1.4 18.6 21.0 806
1×50 2.2 1.3 15.6 17.6 0.3 1.5 20.0 22.8 983
1×70 2.2 1.4 17.6 19.6 0.3 1.6 22.1 25.0 1283
1×95 2.4 1.5 19.8 22.3 0.3 1.7 24.5 27.6 1637
1×120 2.4 1.6 21.7 24.2 0.3 1.7 26.4 29.5 1997
1×150 2.4 1.6 23.2 25.8 0.45 1.8 28.8 32.0 2439
1×185 2.4 1.7 25.2 27.8 0.45 1.9 31.0 34.7 2933
1×240 2.4 1.8 27.9 30.7 0.45 2.0 33.9 37.7 3671
1×300 2.4 1.9 30.4 33.6 0.45 2.1 36.6 40.5 4446
1×400 2.6 2.0 34.1 37.5 0.45 2.3 40.7 45.2 5435
1×500 2.8 2.2 38.0 41.5 0.45 2.5 44.9 49.6 6746
1×630 2.8 2.3 41.6 45.6 0.45 2.6 48.8 54.0 8583
3×25 2.2 1.8 27.4 30.1 0.45 2.0 33.4 37.2 2072
3×35 2.2 1.8 29.3 32.4 0.45 2.1 35.5 39.3 2422
3×50 2.2 1.9 32.1 35.3 0.45 2.2 38.4 42.8 2977
3×70 2.2 2.1 36.2 39.6 0.45 2.4 42.9 47.5 3920
3×95 2.4 2.3 41.0 44.9 0.45 2.6 48.2 53.4 5041
3×120 2.4 2.4 44.9 48.9 0.45 2.7 52.2 57.6 6165
3×150 2.4 2.6 48.4 53.0 0.45 2.9 56.2 61.7 7333
3×185 2.4 2.7 52.5 57.2 0.45 3.0 60.5 66.6 8800
3×240 2.4 3.0 58.5 63.8 0.45 3.3 67.0 73.4 11172
3×300 2.4 3.2 64.0 69.4 0.45 3.5 72.8 79.9 13587

3.3/3.3kV

Construction No. of cores×Cross section Nominal Insulation Thickness Nominal Inner Sheath Thickness Minimum Diameter Over Inner Sheath Maximum Diameter Over Inner Sheath Nominal Armour Wire Diameter Nominal Outer Sheath Thickness Minimum Overall Diameter Maximum Overall Diameter Approx. Weight
mm² mm mm mm mm mm mm mm mm kg/km
1×25 3.0 1.3 15.1 17.1 0.3 1.5 19.4 22.3 789
1×35 3.0 1.3 16.0 18.0 0.3 1.5 20.3 23.2 900
1×50 3.0 1.4 17.4 19.4 0.3 1.6 21.9 24.8 1097
1×70 3.0 1.5 19.3 21.7 0.3 1.6 23.8 26.8 1392
1×95 3.0 1.5 21.0 23.5 0.3 1.7 25.7 28.8 1715
1×120 3.0 1.6 22.9 25.4 0.3 1.8 27.8 30.9 2097
1×150 3.0 1.7 24.5 27.2 0.45 1.9 30.3 34.0 2568
1×185 3.0 1.7 26.3 29.0 0.45 2.0 32.3 36.1 3050
1×240 3.0 1.8 29.0 32.2 0.45 2.1 35.2 39.1 3798
1×300 3.0 1.9 31.6 34.8 0.45 2.2 37.9 41.9 4582
1×400 3.0 2.1 35.1 38.5 0.45 2.3 41.7 46.2 5533
1×500 3.2 2.2 38.7 42.6 0.45 2.5 45.7 50.4 6828
1×630 3.2 2.4 43.6 46.6 0.45 2.6 49.7 55.0 8712
3×25 3.0 1.9 30.9 34.1 0.45 2.1 37.1 41.1 2358
3×35 3.0 2.0 33.0 36.2 0.45 2.2 39.4 43.8 2747
3×50 3.0 2.1 35.8 39.1 0.45 2.3 42.3 46.9 3325
3×70 3.0 2.2 39.7 43.5 0.45 2.5 46.6 51.4 4274
3×95 3.0 2.4 43.7 47.7 0.45 2.7 51.1 56.4 5347
3×120 3.0 2.5 47.5 51.7 0.45 2.8 55.1 60.6 6493
3×150 3.0 2.7 51.1 55.7 0.45 3.0 59.0 65.1 7684
3×185 3.0 2.8 55.2 60.0 0.45 3.2 63.5 69.8 9213
3×240 3.0 3.1 61.2 66.6 0.45 3.4 69.9 76.8 11583
3×300 3.0 3.3 66.6 72.2 0.45 3.6 75.7 82.9 14031

Application and Description

These medium voltage elastomeric insulated cables are designed for fixed wiring in ships and on mobile offshore units, suitable for use in power and control applications.

Standards

  • BS 6883
  • IEC 60332-3A Flame retardant
  • IEC 60754-1; IEC 60754- 2 Corrosivity
  • IEC 61034-2 Smoke density

Cold bend and impact (-40°C) (on request)

CSA C22.2 No. 38-95 (on request)

Construction

ParameterSpecification
ConductorTinned copper wire stranded circular cl. 2 BS 6360/IEC 60228.
InsulationHF-EPR GP5 according to BS 7655 1.2.
Inner SheathHalogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6.
ArmourGalvanized steel wire braid or tinned bronze wire braid (single core).
Outer SheathHalogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6.

Mechanical and Thermal Properties

Minimum Internal Bending Radius : 6×OD

Temperature Range : -40℃ ~ +90℃

Dimensions and Weight

1.9/3.3kV

Construction No. of cores×Cross section Nominal Insulation Thickness Nominal Inner Sheath Thickness Minimum Diameter Over Inner Sheath Maximum Diameter Over Inner Sheath Nominal Armour Wire Diameter Nominal Outer Sheath Thickness Minimum Overall Diameter Maximum Overall Diameter Approx. Weight
mm² mm mm mm mm mm mm mm mm kg/km
1×10 2.2 1.1 10.2 11.9 0.3 1.3 14.2 16.2 398
1×16 2.2 1.2 11.4 13.1 0.3 1.3 15.4 17.6 499
1×25 2.2 1.2 13.0 14.8 0.3 1.4 17.1 19.5 675
1×35 2.2 1.3 14.1 15.9 0.3 1.4 18.2 20.6 793
1×50 2.2 1.3 15.3 17.2 0.3 1.5 19.6 22.4 970
1×70 2.2 1.4 17.2 19.2 0.3 1.6 21.7 24.6 1269
1×95 2.4 1.5 19.4 21.9 0.3 1.7 24.2 27.2 1623
1×120 2.4 1.6 21.3 23.8 0.3 1.7 26.0 29.1 1983
1×150 2.4 1.6 22.8 25.4 0.45 1.8 28.4 31.6 2423
1×185 2.4 1.7 24.8 27.4 0.45 1.9 30.6 34.3 2917
1×240 2.4 1.8 27.5 30.3 0.45 2.0 33.5 37.3 3654
1×300 2.4 1.9 30.0 33.2 0.45 2.1 36.2 40.1 4428
1×400 2.6 2.0 33.8 37.1 0.45 2.3 40.3 44.8 5416
1×500 2.8 2.2 37.6 41.1 0.45 2.5 44.5 49.2 6726
1×630 2.8 2.3 41.2 45.2 0.45 2.6 48.4 53.6 8562
3×10 2.2 1.5 20.4 22.9 0.3 1.7 25.1 28.2 1052
3×16 2.2 1.6 22.8 25.3 0.3 1.8 27.7 30.8 1357
3×25 2.2 1.8 26.6 29.3 0.45 2.0 32.6 36.3 2032
3×35 2.2 1.8 28.4 31.2 0.45 2.1 34.6 38.5 2382
3×50 2.2 1.9 31.2 34.4 0.45 2.2 37.6 41.6 2936
3×70 2.2 2.1 35.3 38.7 0.45 2.4 42.1 46.7 3877
3×95 2.4 2.3 40.2 44.1 0.45 2.6 47.4 52.1 4995
3×120 2.4 2.4 44.0 48.1 0.45 2.7 51.4 56.7 6118
3×150 2.4 2.6 47.6 51.8 0.45 2.9 55.3 60.8 7284
3×185 2.4 2.7 51.7 56.4 0.45 3.0 59.6 65.7 8750
3×240 2.4 3.0 57.7 62.9 0.45 3.3 66.2 72.6 11118
3×300 2.4 3.2 63.1 68.6 0.45 3.5 72.0 79.0 13531

3.3/3.3kV

Construction No. of cores×Cross section Nominal Insulation Thickness Nominal Inner Sheath Thickness Minimum Diameter Over Inner Sheath Maximum Diameter Over Inner Sheath Nominal Armour Wire Diameter Nominal Outer Sheath Thickness Minimum Overall Diameter Maximum Overall Diameter Approx. Weight
mm² mm mm mm mm mm mm mm mm kg/km
1×10 3.0 1.2 12.0 13.7 0.3 1.4 16.1 18.4 483
1×16 3.0 1.2 13.0 14.7 0.3 1.4 17.1 19.4 579
1×25 3.0 1.3 14.7 16.7 0.3 1.5 19.1 21.5 774
1×35 3.0 1.3 15.6 17.6 0.3 1.5 19.9 22.8 885
1×50 3.0 1.4 17.0 19.0 0.3 1.6 21.5 24.4 1082
1×70 3.0 1.5 18.9 21.0 0.3 1.6 23.4 26.4 1377
1×95 3.0 1.5 20.6 23.1 0.3 1.7 25.3 28.4 1699
1×120 3.0 1.6 22.5 25.0 0.3 1.8 27.4 30.5 2081
1×150 3.0 1.7 24.1 26.8 0.45 1.9 30.0 33.6 2550
1×185 3.0 1.7 26.0 28.6 0.45 2.0 32.0 35.7 3032
1×240 3.0 1.8 28.7 31.8 0.45 2.1 34.8 38.7 3780
1×300 3.0 1.9 31.2 34.4 0.45 2.2 37.6 41.5 4563
1×400 3.0 2.1 34.7 38.1 0.45 2.3 41.3 45.8 5514
1×500 3.2 2.2 38.4 41.9 0.45 2.5 45.3 50.0 6807
1×630 3.2 2.4 42.2 46.2 0.45 2.6 49.4 54.6 8691
3×10 3.0 1.7 24.1 26.7 0.45 1.9 29.9 33.6 1404
3×16 3.0 1.8 26.5 29.2 0.45 2.0 32.5 36.2 1738
3×25 3.0 1.9 30.1 33.2 0.45 2.1 36.3 40.2 2314
3×35 3.0 2.0 32.1 35.4 0.45 2.2 38.5 42.9 2701
3×50 3.0 2.1 34.9 38.3 0.45 2.3 41.5 46.0 3278
3×70 3.0 2.2 38.9 42.7 0.45 2.5 45.8 50.5 4226
3×95 3.0 2.4 42.9 46.9 0.45 2.7 50.2 55.5 5297
3×120 3.0 2.5 46.7 50.9 0.45 2.8 54.2 59.7 6442
3×150 3.0 2.7 50.3 54.9 0.45 3.0 58.2 64.2 7631
3×185 3.0 2.8 54.4 59.2 0.45 3.2 62.7 68.9 9158
3×240 3.0 3.1 60.4 65.7 0.45 3.4 69.1 76.0 11526

Application and Description

These medium voltage elastomeric insulated cables are designed for fixed wiring in ships and on mobile offshore units, suitable for use in power and control applications.

Standards

  • BS 6883
  • IEC 60332-3A Flame retardant
  • IEC 60754-1; IEC 60754- 2 Corrosivity
  • IEC 61034-2 Smoke density

Cold bend and impact (-40°C) (on request)

CSA C22.2 No. 38-95 (on request)

Construction

ParameterSpecification
ConductorTinned copper wire stranded circular cl. 2 BS 6360/IEC 60228.
Conductor ScreenSemiconducting layer or tape.
InsulationHF-EPR GP5 according to BS 7655 1.2.
Insulation ScreenSemiconducting layer or tape +Tinned copper tape.
Outer SheathHalogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6.

Mechanical and Thermal Properties

Minimum Internal Bending Radius : 15×OD (single core); 20×OD (three core)

Temperature Range : -40℃ ~ +90℃

Dimensions and Weight

3.8/6.6kV

Construction No. of cores×Cross section Nominal Insulation Thickness Nominal Outer Sheath Thickness Minimum Overall Diameter Maximum Overall Diameter Approx. Weight
mm² mm mm mm mm kg/km
1×16 3.0 1.3 16.0 18.0 492
1×25 3.0 1.3 17.6 19.7 658
1×35 3.0 1.4 18.7 20.8 776
1×50 3.0 1.4 19.9 22.3 942
1×70 3.0 1.5 21.8 24.3 1229
1×95 3.0 1.6 23.7 26.3 1546
1×120 3.0 1.6 25.4 28.0 1890
1×150 3.0 1.7 27.0 29.8 2242
1×185 3.0 1.8 29.0 32.1 2713
1×240 3.0 1.9 31.7 35.0 3427
1×300 3.0 2.0 34.3 37.6 4177
1×400 3.0 2.1 37.6 41.1 5145
1×500 3.2 2.3 41.4 45.5 6408
1×630 3.2 2.4 45.1 49.2 8134
3×16 3.0 1.8 32.7 36.0 1482
3×25 3.0 2.0 36.5 39.9 2031
3×35 3.0 2.0 38.4 41.9 2359
3×50c 3.0 2.2 41.3 45.3 2918
3×70 3.0 2.3 45.3 49.4 3788
3×95 3.0 2.5 49.3 53.9 4776
3×120 3.0 2.6 53.1 57.8 5868
3×150 3.0 2.7 56.5 61.4 6933
3×185 3.0 2.9 60.8 66.1 8401
3×240 3.0 3.1 66.6 72.2 10616

6.35/11kV

Construction No. of cores×Cross section Nominal Insulation Thickness Nominal Outer Sheath Thickness Minimum Overall Diameter Maximum Overall Diameter Approx. Weight
mm² mm mm mm mm kg/km
1×16 3.4 1.3 16.8 18.8 524
1×25 3.4 1.4 18.6 20.7 704
1×35 3.4 1.4 19.4 21.9 813
1×50 3.4 1.5 20.8 23.3 994
1×70 3.4 1.5 22.6 25.1 1272
1×95 3.4 1.6 24.4 27.1 1592
1×120 3.4 1.7 26.3 29.0 1956
1×150 3.4 1.7 27.8 30.6 2294
1×185 3.4 1.8 29.8 32.9 2769
1×240 3.4 1.9 32.5 35.8 3487
1×300 3.4 2.0 35.0 38.4 4242
1×400 3.4 2.1 38.4 41.9 5208
1×500 3.4 2.3 41.8 45.8 6442
1×630 3.4 2.4 45.5 49.6 8176
3×16 3.4 1.9 34.5 37.9 1601
3×25 3.4 2.0 38.2 41.6 2139
3×35 3.4 2.1 40.2 44.1 2497
3×50 3.4 2.2 43.0 47.0 3040
3×70 3.4 2.4 47.1 51.3 3949
3×95 3.4 2.5 51.0 55.6 4919
3×120 3.4 2.7 55.0 59.8 6055
3×150 3.4 2.8 58.4 63.3 7132
3×185 3.4 3.0 62.7 68.1 8613
3×240 3.4 3.2 68.5 74.1 10848

8.7/15kV

Construction No. of cores×Cross section Nominal Insulation Thickness Nominal Outer Sheath Thickness Minimum Overall Diameter Maximum Overall Diameter Approx. Weight
mm² mm mm mm mm kg/km
1×25 4.5 1.5 20.9 23.4 808
1×35 4.5 1.5 21.7 24.3 921
1×50 4.5 1.5 22.9 25.5 1110
1×70 4.5 1.6 24.9 27.5 1396
1×95 4.5 1.7 26.7 29.5 1726
1×120 4.5 1.8 28.6 31.4 2099
1×150 4.5 1.8 30.1 33.3 2445
1×185 4.5 1.9 32.1 35.3 2929
1×240 4.5 2.0 34.8 38.2 3661
1×300 4.5 2.1 37.3 40.8 4429
1×400 4.5 2.2 40.7 44.6 5390
1×500 4.5 2.4 44.1 48.2 6638
1×630 4.5 2.5 47.8 52.0 8415
3×25 4.5 2.2 43.1 47.1 2458
3×35 4.5 2.3 45.2 49.2 2832
3×50 4.5 2.4 47.9 52.1 3395
3×70 4.5 2.6 52.1 56.7 4336
3×95 4.5 2.7 55.9 60.7 5334
3×120 4.5 2.9 59.9 64.9 6500
3×150 4.5 3.0 63.3 68.7 7602
3×185 4.5 3.2 67.6 73.2 9116

Application and Description

These medium voltage elastomeric insulated cables are designed for fixed wiring in ships and on mobile offshore units, suitable for use in power and control applications.

Standards

  • BS 6883
  • IEC 60332-3A Flame retardant
  • IEC 60754-1; IEC 60754- 2 Corrosivity
  • IEC 61034-2 Smoke density

Cold bend and impact (-40°C) (on request)

CSA C22.2 No. 38-95 (on request)

Construction

ParameterSpecification
ConductorTinned copper wire stranded circular cl. 2 BS 6360/IEC 60228.
Conductor ScreenSemiconducting layer or tape.
InsulationHF-EPR GP5 according to BS 7655 1.2.
Insulation ScreenSemiconducting layer or tape +Tinned copper tape.
Inner SheathHalogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6.
ArmourGalvanized steel wire braid or tinned bronze wire braid (single core).
Outer SheathHalogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6.

Mechanical and Thermal Properties

Minimum Internal Bending Radius : 15×OD (single core); 20×OD (three core)

Temperature Range : -40℃ ~ +90℃

Dimensions and Weight

3.8/6.6kV

Construction No. of cores×Cross section Nominal Insulation Thickness Nominal Inner Sheath Thickness Minimum Diameter Over Inner Sheath Maximum Diameter Over Inner Sheath Nominal Armour Wire Diameter Nominal Outer Sheath Thickness Minimum Overall Diameter Maximum Overall Diameter Approx. Weight
mm² mm mm mm mm mm mm mm mm kg/km
1×16 3.0 1.3 16.0 18.0 0.3 1.4 20.2 23.0 790
1×25 3.0 1.3 17.6 19.7 0.3 1.5 21.9 24.9 950
1×35 3.0 1.4 18.7 20.8 0.3 1.5 23.0 26.0 1060
1×50 3.0 1.4 19.9 22.3 0.3 1.6 24.4 27.4 1320
1×70 3.0 1.5 21.8 24.3 0.3 1.7 26.5 29.6 1610
1×95 3.0 1.6 23.7 26.3 0.3 1.8 28.6 31.8 1930
1×120 3.0 1.6 25.4 28.0 0.3 1.8 30.2 33.9 2260
1×150 3.0 1.7 27.0 29.8 0.45 1.9 32.8 36.6 2760
1×185 3.0 1.8 29.0 32.1 0.45 2.0 35.0 38.9 3210
1×240 3.0 1.9 31.7 35.0 0.45 2.1 37.9 41.9 3960
1×300 3.0 2.0 34.3 37.6 0.45 2.2 40.6 45.1 4660
1×400 3.0 2.1 37.6 41.4 0.45 2.4 44.4 49.0 5470
1×500 3.2 2.3 41.4 45.4 0.45 2.5 48.4 53.6 6610
1×630 3.2 2.4 45.1 49.2 0.45 2.7 52.4 57.8 8230
3×16 3.0 1.8 32.7 36.0 0.45 2.1 38.9 43.3 2610
3×25 3.0 2.0 36.5 39.9 0.45 2.2 42.9 47.5 3220
3×35 3.0 2.0 38.4 41.9 0.45 2.3 44.9 49.6 3700
3×50 3.0 2.2 41.3 45.3 0.45 2.4 48.1 53.3 4360
3×70 3.0 2.3 45.3 49.4 0.45 2.6 52.4 57.4 5410
3×95 3.0 2.5 49.3 53.9 0.45 2.8 56.8 62.4 6710
3×120 3.0 2.6 53.1 57.8 0.45 2.9 60.8 67.0 7770
3×150 3.0 2.7 56.6 61.4 0.45 3.1 64.6 70.9 9160
3×185 3.0 2.9 60.8 66.1 0.45 3.2 69.1 76.0 10430
3×240 3.0 3.1 66.6 72.2 0.45 3.5 75.5 82.6 12840

6.35/11kV

Construction No. of cores×Cross section Nominal Insulation Thickness Nominal Inner Sheath Thickness Minimum Diameter Over Inner Sheath Maximum Diameter Over Inner Sheath Nominal Armour Wire Diameter Nominal Outer Sheath Thickness Minimum Overall Diameter Maximum Overall Diameter Approx. Weight
mm² mm mm mm mm mm mm mm mm kg/km
1×16 3.4 1.3 16.8 18.8 0.3 1.5 21.1 24 810
1×25 3.4 1.4 18.6 20.7 0.3 1.5 22.9 25.9 980
1×35 3.4 1.4 19.4 21.9 0.3 1.6 24.0 27.0 1110
1×50 3.4 1.5 20.8 23.3 0.3 1.6 25.3 28.4 1360
1×70 3.4 1.5 22.6 25.1 0.3 1.7 27.3 30.4 1660
1×95 3.4 1.6 24.4 27.1 0.3 1.8 29.3 33.0 1970
1×120 3.4 1.7 26.3 29.0 0.45 1.9 32.1 35.9 2360
1×150 3.4 1.7 27.8 30.6 0.45 2.0 33.8 37.6 2810
1×185 3.4 1.8 29.8 32.9 0.45 2.0 35.8 39.7 3260
1×240 3.4 1.9 32.5 35.8 0.45 2.2 38.9 43.3 4020
1×300 3.4 2.0 35.0 38.4 0.45 2.3 41.6 46.1 4760
1×400 3.4 2.1 38.4 41.9 0.45 2.4 45.1 49.8 5610
1×500 3.4 2.3 41.8 45.8 0.45 2.5 48.8 54.0 6820
1×630 3.4 2.4 45.5 49.6 0.45 2.7 52.8 58.2 8480
3×16 3.4 1.9 34.5 37.9 0.45 2.1 40.7 45.2 2660
3×25 3.4 2.0 38.2 41.6 0.45 2.3 44.7 49.4 3310
3×35 3.4 2.1 40.2 44.1 0.45 2.4 47.0 51.7 3960
3×50 3.4 2.2 43.0 47.0 0.45 2.5 50.0 55.2 4570
3×70 3.4 2.4 47.1 51.3 0.45 2.7 54.4 59.9 5610
3×95 3.4 2.5 51.0 55.6 0.45 2.8 58.5 64.5 6820
3×120 3.4 2.7 55.0 59.8 0.45 3.0 62.9 69.1 8070
3×150 3.4 2.8 58.4 63.3 0.45 3.1 66.5 72.8 9260
3×185 3.4 3.0 62.7 68.1 0.45 3.3 71.2 78.1 10960
3×240 3.4 3.2 68.5 74.1 0.45 3.6 77.5 85.2 13390

8.7/15kV

Construction No. of cores×Cross section Nominal Insulation Thickness Nominal Inner Sheath Thickness Minimum Diameter Over Inner Sheath Maximum Diameter Over Inner Sheath Nominal Armour Wire Diameter Nominal Outer Sheath Thickness Minimum Overall Diameter Maximum Overall Diameter Approx. Weight
mm² mm mm mm mm mm mm mm mm kg/km
1×25 4.5 1.5 20.9 23.4 0.3 1.6 25.4 28.5 1150
1×35 4.5 1.5 21.7 24.3 0.3 1.7 26.4 29.6 1260
1×50 4.5 1.5 22.9 25.5 0.3 1.7 27.6 30.8 1510
1×70 4.5 1.6 24.9 27.5 0.3 1.8 29.8 33.4 1770
1×95 4.5 1.7 26.7 29.5 0.45 1.9 32.6 36.3 2270
1×120 4.5 1.8 28.6 31.4 0.45 2.0 34.6 38.5 2730
1×150 4.5 1.8 30.1 33.3 0.45 2.1 36.3 40.2 3020
1×185 4.5 1.9 32.1 35.3 0.45 2.1 38.3 42.3 3490
1×240 4.5 2.0 34.8 38.2 0.45 2.2 41.2 45.7 4260
1×300 4.5 2.1 37.3 40.8 0.45 2.4 44.1 48.7 4810
1×400 4.5 2.2 40.7 44.6 0.45 2.5 47.6 52.4 6160
1×500 4.5 2.4 44.1 48.2 0.45 2.6 51.3 56.6 7330
1×630 4.5 2.5 47.8 52.0 0.45 2.8 55.3 60.8 8800
3×25 4.5 2.2 43.1 47.1 0.45 2.5 50.1 55.4 3610
3×35 4.5 2.3 45.2 49.2 0.45 2.6 52.3 57.7 4510
3×50 4.5 2.4 47.9 52.1 0.45 2.7 55.3 60.8 5210
3×70 4.5 2.6 52.1 56.7 0.45 2.9 59.8 65.9 6390
3×95 4.5 2.7 55.9 60.7 0.45 3.0 63.8 70.1 7660
3×120 4.5 2.9 59.9 64.9 0.45 3.2 68.2 75.1 8810
3×150 4.5 3.0 63.3 68.7 0.45 3.3 71.8 78.8 10070
3×185 4.5 3.2 67.6 73.2 0.45 3.5 76.5 83.7 11420

Application and Description

These medium voltage elastomeric insulated cables are designed for fixed wiring in ships and on mobile offshore units, suitable for use in power and control applications.

Standards

  • BS 6883
  • IEC 60332-3A Flame retardant
  • IEC 60754-1; IEC 60754- 2 Corrosivity
  • IEC 61034-2 Smoke density

Cold bend and impact (-40°C) (on request)

CSA C22.2 No. 38-95 (on request)

Construction

ParameterSpecification
ConductorTinned copper wire stranded circular cl. 2 BS 6360/IEC 60228.
Conductor ScreenSemiconducting layer or tape.
InsulationHF-EPR GP5 according to BS 7655 1.2.
Inner SheathHalogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6.
ArmourGalvanized steel wire braid or tinned bronze wire braid (single core).
Outer SheathHalogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6.

Mechanical and Thermal Properties

Minimum Internal Bending Radius : 12×OD

Temperature Range : -40℃ ~ +90℃

Dimensions and Weight

3.8/6.6kV

Construction No. of cores×Cross section Nominal Insulation Thickness Nominal Inner Sheath Thickness Minimum Diameter Over Inner Sheath Maximum Diameter Over Inner Sheath Nominal Armour Wire Diameter Nominal Outer Sheath Thickness Minimum Overall Diameter Maximum Overall Diameter Approx. Weight
mm² mm mm mm mm mm mm mm mm kg/km
1×16 3.4 1.3 13.9 15.7 0.3 1.4 18.0 20.4 703
1×25 3.4 1.3 15.5 17.5 0.3 1.5 19.8 22.7 899
1×35 3.4 1.4 16.6 18.6 0.3 1.5 20.9 23.8 1029
1×50 3.4 1.4 17.8 19.8 0.3 1.6 22.3 25.2 1223
1×70 3.4 1.5 19.7 22.1 0.3 1.7 24.4 27.4 1547
1×95 3.4 1.6 21.6 24.1 0.3 1.8 26.5 29.6 1903
1×120 3.4 1.6 23.2 25.8 0.3 1.8 28.1 31.3 2266
1×150 3.4 1.7 24.9 27.6 0.45 1.9 30.7 34.4 2760
1×185 3.4 1.8 26.9 29.6 0.45 2.0 32.9 36.7 3282
1×240 3.4 1.9 29.6 32.8 0.45 2.1 35.8 39.7 4059
1×300 3.4 2.0 32.1 35.4 0.45 2.2 38.5 42.9 4872
1×400 3.4 2.1 35.5 38.9 0.45 2.4 42.2 46.8 5844
1×500 3.4 2.2 38.7 42.6 0.45 2.5 45.7 50.4 7113
1×630 3.4 2.4 42.6 46.6 0.45 2.7 49.9 55.2 9093
3×16 3.4 1.8 28.1 30.9 0.45 2.1 34.3 38.2 2109
3×25 3.4 2.0 31.9 35.2 0.45 2.2 38.3 42.3 2747
3×35 3.4 2.0 33.8 37.1 0.45 2.3 40.4 44.9 3133
3×50 3.4 2.2 36.8 40.2 0.45 2.4 43.5 48.2 3772
3×70 3.4 2.3 40.7 44.6 0.45 2.6 47.9 52.7 4771
3×95 3.4 2.5 44.7 48.8 0.45 2.8 52.3 57.7 5900
3×120 3.4 2.6 48.6 53.1 0.45 2.9 56.3 61.8 7098
3×150 3.4 2.7 51.9 56.6 0.45 3.1 60.1 66.2 8304
3×185 3.4 2.9 56.2 61.1 0.45 3.2 64.6 70.8 9895
3×240 3.4 3.1 62.0 67.4 0.45 3.5 70.9 77.9 12358

6.6/6.6kV

Construction No. of cores×Cross section Nominal Insulation Thickness Nominal Inner Sheath Thickness Minimum Diameter Over Inner Sheath Maximum Diameter Over Inner Sheath Nominal Armour Wire Diameter Nominal Outer Sheath Thickness Minimum Overall Diameter Maximum Overall Diameter Approx. Weight
mm² mm mm mm mm mm mm mm mm kg/km
1×25 5.5 1.5 19.9 22.4 0.3 1.7 24.6 27.7 1211
1×35 5.5 1.5 20.8 23.3 0.3 1.7 25.5 28.6 1338
1×50 5.5 1.6 22.2 24.7 0.3 1.8 27.1 30.2 1565
1×70 5.5 1.7 24.1 26.7 0.45 1.9 29.9 33.6 2017
1×95 5.5 1.7 25.8 28.5 0.45 2.0 31.8 35.5 2383
1×120 5.5 1.8 27.7 30.4 0.45 2.0 33.7 37.5 2794
1×150 5.5 1.9 29.3 32.5 0.45 2.1 35.5 39.4 3213
1×185 5.5 1.9 31.1 34.3 0.45 2.2 37.5 41.5 3737
1×240 5.5 2.0 33.8 37.2 0.45 2.3 40.4 44.9 4548
1×300 5.5 2.1 36.4 39.8 0.45 2.4 43.1 47.7 5392
1×400 5.5 2.3 39.9 43.8 0.45 2.6 47.0 51.8 6384
1×500 5.5 2.4 43.2 47.2 0.45 2.7 50.5 55.8 7689
1×630 5.5 2.5 46.8 51.0 0.45 2.8 54.3 59.8 9709
3×25 5.5 2.3 41.2 45.1 0.45 2.6 48.4 53.6 3746
3×35 5.5 2.4 43.3 47.3 0.45 2.7 50.6 55.9 4204
3×50 5.5 2.5 46.1 50.2 0.45 2.8 53.6 59.0 4872
3×70 5.5 2.7 50.2 54.8 0.45 3.0 58.1 64.1 5992
3×95 5.5 2.8 54.0 58.8 0.45 3.1 62.1 68.3 7130
3×120 5.5 3.0 58.0 63.0 0.45 3.3 66.5 72.9 8486
3×150 5.5 3.1 61.4 66.8 0.45 3.4 70.1 77.0 9723
3×185 5.5 3.3 65.7 71.3 0.45 3.6 74.8 81.9 11448
3×240 5.5 3.5 71.5 77.6 0.45 3.9 81.2 89.0 14038

6.35/11kV

Construction No. of cores×Cross section Nominal Insulation Thickness Nominal Inner Sheath Thickness Minimum Diameter Over Inner Sheath Maximum Diameter Over Inner Sheath Nominal Armour Wire Diameter Nominal Outer Sheath Thickness Minimum Overall Diameter Maximum Overall Diameter Approx. Weight
mm² mm mm mm mm mm mm mm mm kg/km
1×35 6.5 1.6 22.9 25.5 0.3 1.8 27.8 31.0 1514
1×50 6.5 1.7 24.3 26.9 0.45 1.9 30.1 33.8 1751
1×70 6.5 1.7 26.0 28.7 0.45 2.0 32.0 35.8 2201
1×95 6.5 1.8 27.9 30.7 0.45 2.1 34.1 37.9 2600
1×120 6.5 1.9 29.8 32.9 0.45 2.1 36.0 39.9 3021
1×150 6.5 1.9 31.2 34.5 0.45 2.2 37.6 41.6 3427
1×185 6.5 2.0 33.3 36.5 0.45 2.3 39.8 44.3 3987
1×240 6.5 2.1 36.0 39.4 0.45 2.4 42.7 47.3 4814
1×300 6.5 2.2 38.5 42.3 0.45 2.5 45.4 50.1 5674
1×400 6.5 2.4 42.0 46.0 0.45 2.6 49.2 54.4 6637
1×500 6.5 2.5 45.3 49.4 0.45 2.8 52.8 58.2 7986
1×630 6.5 2.6 48.9 53.5 0.45 2.9 56.6 62.2 10057
3×35 6.5 2.6 47.8 52.0 0.45 2.9 55.5 61.1 4793
3×50 6.5 2.7 50.6 55.2 0.45 3.0 58.5 64.6 5489
3×70 6.5 2.8 54.5 59.3 0.45 3.2 62.8 69.0 6612
3×95 6.5 3.0 58.6 63.5 0.45 3.3 67.0 73.4 7829
3×120 6.5 3.1 62.4 67.8 0.45 3.5 71.3 78.2 9182
3×150 6.5 3.3 66.0 71.5 0.45 3.6 75.0 82.2 10498
3×185 6.5 3.4 70.1 76.1 0.45 3.8 79.5 87.2 12218

Certificate Display

ISO 9001 Quality Management System
ISO 9001 Certificate (2025–2028)
ISO 9001 Certificate (NOA)
CE — Verification of Conformity
RoHS Compliance Attestation (EU)
Low Voltage Directive Attestation (EU)

Type and routine tests are issued from our own testing centre under the ISO 9001 quality system — test reports and certificates accompany every shipment.

Factory Tour

Why Choose Us

50+ years of experience Trusted manufacturing expertise since 1969
International standards IEC, ASTM, BS, CSA and other global standards
Strict quality control Comprehensive testing throughout production
Large production capacity Reliable supply for utility and EPC projects
Fast global delivery Efficient manufacturing and worldwide shipping
Technical support Expert assistance from inquiry to project completion

Packing & Shipping

  • Wooden, steel or steel-wood drums; drum length to customer requirement
  • Drum marking per customer / utility specification
  • Both drum ends sealed and protected for sea freight
Get in touch

Ready for Your Next Cable Project?

Send us your specifications, cable schedule or RFQ — our engineering team replies with a technical proposal and price within one working day.

  • Emailinfo@qzcablegroup.com
  • WhatsApp / WeChat+86 173 3570 4553
  • Contact personChloe · Export Department
  • Factory addressWest Industrial Park, Zhulin Town, Gongyi City, Henan Province, China

    The more specific the standard and size, the faster we can quote.
    Inquiry WhatsApp Email