JIS — C 3410 Shipboard Cables
- Standards: JISC 3410-1999 · IEC 60332-1 · IEC 60332-3 · IEC 60228 · JIS C 3401 · JIS C 3410
Product Description
-
0.6/1kV
(FA-)SPYC, SPYCBSTANDARDS
IEC 60332-3 Cat.A(for FA-type)
CABLE CONSTRUCTION
Cable Parameter
(FA-)SPYC, SPYCB
(FA-)SPYCY, SPYCBY
STANDARDS
JISC 3410-1999
IEC 60332-1
IEC 60332-3 Cat.A(for FA-type)
CABLE CONSTRUCTION
| Conductor | S | Tinned annealed stranded copper, class 2 according to IEC 60228 |
| Insulation | P | 85°C EPR as per JIS C 3401 |
| Bedding | Y | PVC as per JIS C 3401 |
| Armor | C (CB) | Galvanized steel wire braid(-C TYPE) or copper alloy wire braid(-CB TYPE) |
| Sheath | Y | PVC as per JIS C 3401 |
| Outer sheath color | Black |
Cable Parameter
(FA-)SPYC, SPYCB
| Conductor | Thick. of insulation | Thick. of bedding | Dia. over bedding | Dia. of armor | (FA-) SPYC, SPYCB | ||||
| Size | Construction | O.D | Nominal overall dia. | Tolerance | Cable weight (Approx.) | ||||
| mm² | No./mm | mm | mm | mm | mm | mm | mm | mm | Kg/Km |
| 1.5 | 7/0.53 | 1.59 | 1.0 | 1.0 | 5.9 | 0.3 | 7.2 | 0.4 | 100 |
| 2.5 | 7/0.67 | 2.01 | 1.0 | 1.0 | 6.3 | 0.3 | 7.8 | 0.4 | 120 |
| 4 | 7/0.85 | 2.55 | 1.0 | 1.0 | 6.9 | 0.3 | 8.2 | 0.4 | 140 |
| 6 | 7/1.04 | 3.12 | 1.0 | 1.0 | 7.4 | 0.3 | 8.7 | 0.4 | 170 |
| 10 | 7/1.35 | 4.05 | 1.0 | 1.1 | 8.6 | 0.3 | 9.9 | 0.4 | 225 |
| 16 | 7/1.70 | 5.1 | 1.0 | 1.1 | 9.6 | 0.3 | 10.9 | 0.4 | 300 |
| 25 | 7/2.14 | 6.42 | 1.2 | 1.2 | 11.5 | 0.3 | 12.8 | 0.5 | 425 |
| 35 | 7/2.52 | 7.56 | 1.2 | 1.2 | 12.7 | 0.3 | 14.0 | 0.6 | 535 |
| 50 | 19/1.78 | 8.9 | 1.4 | 1.3 | 14.6 | 0.3 | 15.9 | 0.6 | 695 |
| 70 | 19/2.14 | 10.7 | 1.6 | 1.4 | 17.2 | 0.3 | 18.5 | 0.7 | 960 |
| 95 | 19/2.52 | 12.6 | 1.6 | 1.5 | 19.3 | 0.3 | 20.6 | 0.8 | 1250 |
| 120 | 37/2.03 | 14.2 | 1.6 | 1.5 | 20.9 | 0.3 | 22.2 | 0.9 | 1510 |
| 150 | 37/2.25 | 15.8 | 1.8 | 1.6 | 23.1 | 0.3 | 24.4 | 1.0 | 1830 |
| 185 | 37/2.52 | 17.6 | 2.0 | 1.7 | 25.5 | 0.3 | 26.8 | 1.1 | 2250 |
| 240 | 61/2.25 | 20.3 | 2.2 | 1.8 | 28.8 | 0.3 | 30.1 | 1.2 | 2910 |
| 300 | 61/2.52 | 22..7 | 2.4 | 1.9 | 31.8 | 0.4 | 33.6 | 1.3 | 3680 |
(FA-)SPYCY, SPYCBY
| Conductor | Thick. of insulation | Thick. of bedding | Dia. over bedding | Dia. of armor | (FA-) SPYCY, SPYCBY | |||||
| Size | Construction | O.D | Thick.of Sheath | Nominal overall dia. | Tolerance | Cable weight (Approx.) | ||||
| mm² | No./mm | mm | mm | mm | mm | mm | mm | mm | mm | Kg/Km |
| 1.5 | 7/0.53 | 1.59 | 1.0 | 1.0 | 5.9 | 0.3 | 0.8 | 9.0 | 0.4 | 135 |
| 2.5 | 7/0.67 | 2.01 | 1.0 | 1.0 | 6.3 | 0.3 | 0.8 | 9.4 | 0.4 | 150 |
| 4 | 7/0.85 | 2.55 | 1.0 | 1.0 | 6.9 | 0.3 | 0.8 | 10.0 | 0.4 | 175 |
| 6 | 7/1.04 | 3.12 | 1.0 | 1.0 | 7.4 | 0.3 | 0.8 | 10.5 | 0.4 | 205 |
| 10 | 7/1.35 | 4.05 | 1.0 | 1.1 | 8.6 | 0.3 | 0.8 | 11.7 | 0.5 | 270 |
| 16 | 7/1.70 | 5.1 | 1.0 | 1.1 | 9.6 | 0.3 | 0.9 | 12.9 | 0.5 | 350 |
| 25 | 7/2.14 | 6.42 | 1.2 | 1.2 | 11.5 | 0.3 | 0.9 | 14.8 | 0.6 | 485 |
| 35 | 7/2.52 | 7.56 | 1.2 | 1.2 | 12.7 | 0.3 | 1.0 | 16.2 | 0.6 | 605 |
| 50 | 19/1.78 | 8.9 | 1.4 | 1.3 | 14.6 | 0.3 | 1.0 | 18.1 | 0.7 | 775 |
| 70 | 19/2.14 | 10.7 | 1.6 | 1.4 | 17.2 | 0.3 | 1.1 | 20.9 | 0.8 | 1060 |
| 95 | 19/2.52 | 12.6 | 1.6 | 1.5 | 19.3 | 0.3 | 1.1 | 23.0 | 0.9 | 1360 |
| 120 | 37/2.03 | 14.2 | 1.6 | 1.5 | 20.9 | 0.3 | 1.2 | 24.8 | 1.0 | 1650 |
| 150 | 37/2.25 | 15.8 | 1.8 | 1.6 | 23.1 | 0.3 | 1.2 | 27.0 | 1.1 | 1980 |
| 185 | 37/2.52 | 17.6 | 2.0 | 1.7 | 25.5 | 0.3 | 1.3 | 29.6 | 1.2 | 2420 |
| 240 | 61/2.25 | 20.3 | 2.2 | 1.8 | 28.8 | 0.3 | 1.4 | 33.1 | 1.3 | 3110 |
| 300 | 61/2.52 | 22..7 | 2.4 | 1.9 | 31.8 | 0.4 | 1.4 | 36.6 | 1.5 | 3910 |
[FA-] DPY, TPY, FPY, 5PY, 6PYSTANDARDS
IEC 60332-3 Cat.A(for FA-type)
CABLE CONSTRUCTION
Cable Parameter
0.6/1KV (FA-) DPY
0.6/1KV (FA-) DPYC
0.6/1KV (FA-) DPYCY
0.6/1KV (FA-) TPY
0.6/1KV (FA-) TPYC
0.6/1KV (FA-) TPYCY
0.6/1KV (FA-) FPY
0.6/1KV (FA-) FPYC
0.6/1KV (FA-) FPYCY
0.6/1KV (FA-) 5PY
0.6/1KV (FA-) 5PYC
0.6/1KV (FA-) 5PYCY
0.6/1KV (FA-) 6PY
0.6/1KV (FA-) 6PYC
0.6/1KV (FA-) 6PYCY
[FA-] DPYC, TPYC, FPYC, 5PYC, 6PYCSTANDARDS
IEC 60332-3 Cat.A(for FA-type)
CABLE CONSTRUCTION
Cable Parameter
0.6/1KV (FA-) DPY
0.6/1KV (FA-) DPYC
0.6/1KV (FA-) DPYCY
0.6/1KV (FA-) TPY
0.6/1KV (FA-) TPYC
0.6/1KV (FA-) TPYCY
0.6/1KV (FA-) FPY
0.6/1KV (FA-) FPYC
0.6/1KV (FA-) FPYCY
0.6/1KV (FA-) 5PY
0.6/1KV (FA-) 5PYC
0.6/1KV (FA-) 5PYCY
0.6/1KV (FA-) 6PY
0.6/1KV (FA-) 6PYC
0.6/1KV (FA-) 6PYCY
STANDARDS
JISC 3410-1999
IEC 60332-1
IEC 60332-3 Cat.A(for FA-type)
CABLE CONSTRUCTION
| Conductor | D(T,F,5,6,10) | Tinned annealed stranded copper, class 2 according to IEC 60228 |
| Insulation | P | 85°C EPR as per JIS C 3401 |
| Cabling |
Insulated conductors shall be cabled. Flame retardant & non-hygroscopic fillers may be used |
|
| Bedding | Y | PVC as per JIS C 3401 |
| Armor | C | Galvanized steel wire braid |
| Sheath | Y | PVC as per JIS C 3401 |
| Core identification |
2C Black, White – 3C / 2C+E Black, White, Red/ Black, White, G/Y 4C / 3C+E Black, White, Red, Green /Black, White, Red, G/Y 5C and over Black No. on white insulation /Black No. on white insulation, G/Y |
|
| Outer sheath color | Black |
Cable Parameter
0.6/1KV (FA-) DPY
| Conductor | Thick. of insulation | Thick. of bedding | (FA-) DPY | ||||
| Size | Construction | O.D | Nominal overall dia. | Tolerance | Cable weight (Approx.) | ||
| mm² | No./mm | mm | mm | mm | mm | mm | Kg/Km |
| 1.5 | 7/0.53 | 1.59 | 1 | 1.1 | 10.4 | 0.5 | 120 |
| 2.5 | 7/0.67 | 2.01 | 1 | 1.2 | 11.5 | 0.5 | 155 |
| 4 | 7/0.85 | 2.55 | 1 | 1.2 | 12.6 | 0.6 | 200 |
| 6 | 7/1.04 | 3.12 | 1 | 1.3 | 13.9 | 0.6 | 255 |
| 10 | 7/1.35 | 4.05 | 1 | 1.3 | 15.8 | 0.7 | 360 |
| 16 | 7/1.70 | 5.1 | 1 | 1.4 | 18.1 | 0.8 | 515 |
| 25 | 7/2.14 | 6.42 | 1.2 | 1.5 | 21.7 | 0.9 | 770 |
| 35 | 7/2.52 | 7.56 | 1.2 | 1.6 | 24.2 | 1 | 1010 |
| 50 | 19/1.78 | 8.9 | 1.4 | 1.8 | 28.1 | 1.2 | 1360 |
| 70 | 19/2.14 | 10.7 | 1.6 | 2 | 33.3 | 1.4 | 1930 |
| 95 | 19/2.52 | 12.6 | 1.6 | 2.1 | 37.3 | 1.6 | 2550 |
| 120 | 37/2.03 | 14.2 | 1.6 | 2.3 | 40.9 | 1.6 | 3150 |
| 150 | 37/2.25 | 15.8 | 1.8 | 2.4 | 45 | 1.7 | 3840 |
| 185 | 37/2.52 | 17.6 | 2 | 2.6 | 50 | 1.9 | 4780 |
0.6/1KV (FA-) DPYC
| Conductor | Thick. of insulation | Thick. of bedding | Dia. of steel wire | (FA-) DPYC | ||||
| Size | Construction | O.D | Nominal overall dia. | Tolerance | Cable weight (Approx.) | |||
| mm² | No./mm | mm | mm | mm | mm | mm | mm | Kg/Km |
| 1.5 | 7/0.53 | 1.59 | 1 | 1.1 | 0.3 | 11.7 | 0.5 | 205 |
| 2.5 | 7/0.67 | 2.01 | 1 | 1.2 | 0.3 | 12.8 | 0.5 | 250 |
| 4 | 7/0.85 | 2.55 | 1 | 1.2 | 0.3 | 13.9 | 0.6 | 300 |
| 6 | 7/1.04 | 3.12 | 1 | 1.3 | 0.3 | 15.2 | 0.6 | 370 |
| 10 | 7/1.35 | 4.05 | 1 | 1.3 | 0.3 | 17.1 | 0.7 | 490 |
| 16 | 7/1.70 | 5.1 | 1 | 1.4 | 0.3 | 19.4 | 0.8 | 660 |
| 25 | 7/2.14 | 6.42 | 1.2 | 1.5 | 0.3 | 23 | 0.9 | 945 |
| 35 | 7/2.52 | 7.56 | 1.2 | 1.6 | 0.3 | 25.5 | 1 | 1200 |
| 50 | 19/1.78 | 8.9 | 1.4 | 1.8 | 0.3 | 29.4 | 1.2 | 1580 |
| 70 | 19/2.14 | 10.7 | 1.6 | 2 | 0.4 | 35.1 | 1.4 | 2300 |
| 95 | 19/2.52 | 12.6 | 1.6 | 2.1 | 0.4 | 39.1 | 1.6 | 2960 |
| 120 | 37/2.03 | 14.2 | 1.6 | 2.3 | 0.4 | 42.7 | 1.6 | 3600 |
| 150 | 37/2.25 | 15.8 | 1.8 | 2.4 | 0.4 | 46.8 | 1.7 | 4330 |
| 185 | 37/2.52 | 17.6 | 2 | 2.6 | 0.4 | 51.8 | 1.9 | 5330 |
0.6/1KV (FA-) DPYCY
| Conductor | Thick. of insulation | Thick. of bedding | Dia. of steel wire | (FA-) DPYCY | |||||
| Size | Construction | O.D | Thick. of covering | Nominal overall dia. | Tolerance | Cable weight (Approx.) | |||
| mm² | No./mm | mm | mm | mm | mm | mm | mm | mm | Kg / Km |
| 1.5 | 7/0.53 | 1.59 | 1 | 1.1 | 0.3 | 0.9 | 13.7 | 0.5 | 260 |
| 2.5 | 7/0.67 | 2.01 | 1 | 1.2 | 0.3 | 0.9 | 14.8 | 0.6 | 310 |
| 4 | 7/0.85 | 2.55 | 1 | 1.2 | 0.3 | 0.9 | 15.9 | 0.6 | 365 |
| 6 | 7/1.04 | 3.12 | 1 | 1.3 | 0.3 | 1 | 17.4 | 0.7 | 445 |
| 10 | 7/1.35 | 4.05 | 1 | 1.3 | 0.3 | 1 | 19.3 | 0.8 | 575 |
| 16 | 7/1.70 | 5.1 | 1 | 1.4 | 0.3 | 1.1 | 21.8 | 0.9 | 765 |
| 25 | 7/2.14 | 6.42 | 1.2 | 1.5 | 0.3 | 1.2 | 25.6 | 1 | 1080 |
| 35 | 7/2.52 | 7.56 | 1.2 | 1.6 | 0.3 | 1.2 | 28.1 | 1.1 | 1350 |
| 50 | 19/1.78 | 8.9 | 1.4 | 1.8 | 0.3 | 1.3 | 32.2 | 1.3 | 1770 |
| 70 | 19/2.14 | 10.7 | 1.6 | 2 | 0.4 | 1.5 | 38.5 | 1.5 | 2570 |
| 95 | 19/2.52 | 12.6 | 1.6 | 2.1 | 0.4 | 1.6 | 42.7 | 1.6 | 3280 |
| 120 | 37/2.03 | 14.2 | 1.6 | 2.3 | 0.4 | 1.7 | 46.5 | 1.7 | 3970 |
| 150 | 37/2.25 | 15.8 | 1.8 | 2.4 | 0.4 | 1.8 | 50.8 | 1.8 | 4750 |
| 185 | 37/2.52 | 17.6 | 2 | 2.6 | 0.4 | 1.9 | 56 | 1.9 | 5810 |
0.6/1KV (FA-) TPY
| Conductor | Thick. of insulation | Thick. of bedding | (FA-) TPY | ||||
| Size | Construction | O.D | Nominal overall dia. | Tolerance | Cable weight (Approx.) | ||
| mm² | No./mm | mm | mm | mm | mm | mm | Kg/Km |
| 1.5 | 7/0.53 | 1.59 | 1.0 | 1.2 | 11.2 | 0.5 | 150 |
| 2.5 | 7/0.67 | 2.01 | 1.0 | 1.2 | 12.2 | 0.5 | 195 |
| 4 | 7/0.85 | 2.55 | 1.0 | 1.2 | 13.4 | 0.6 | 255 |
| 6 | 7/1.04 | 3.12 | 1.0 | 1.3 | 14.8 | 0.6 | 335 |
| 10 | 7/1.35 | 4.05 | 1.0 | 1.4 | 17.0 | 0.7 | 485 |
| 16 | 7/1.70 | 5.1 | 1.0 | 1.5 | 19.5 | 0.8 | 700 |
| 25 | 7/2.14 | 6.42 | 1.2 | 1.6 | 23.4 | 1.0 | 1060 |
| 35 | 7/2.52 | 7.56 | 1.2 | 1.7 | 26.1 | 1.1 | 1390 |
| 50 | 19/1.78 | 8.9 | 1.4 | 1.9 | 30.2 | 1.3 | 1870 |
| 70 | 19/2.14 | 10.7 | 1.6 | 2.1 | 35.8 | 1.5 | 2660 |
| 95 | 19/2.52 | 12.6 | 1.6 | 2.2 | 40.1 | 1.6 | 3530 |
| 120 | 37/2.03 | 14.2 | 1.6 | 2.4 | 44.0 | 1.7 | 4370 |
| 150 | 37/2.25 | 15.8 | 1.8 | 2.5 | 48.4 | 1.8 | 5340 |
| 185 | 37/2.52 | 17.6 | 2.0 | 2.7 | 53.7 | 1.9 | 6640 |
| 240 | 61/2.25 | 20.25 | 2.2 | 3.0 | 60.4 | 2.3 | 8880 |
0.6/1KV (FA-) TPYC
| Conductor | Thick. of insulation | Thick. of bedding | Dia. of steel wire | (FA-) TPYC | ||||
| Size | Construction | O.D | Nominal overall dia. | Tolerance | Cable weight (Approx.) | |||
| mm² | No./mm | mm | mm | mm | mm | mm | mm | Kg / Km |
| 1.5 | 7/0.53 | 1.59 | 1.0 | 1.2 | 0.3 | 12.5 | 0.5 | 245 |
| 2.5 | 7/0.67 | 2.01 | 1.0 | 1.2 | 0.3 | 13.5 | 0.5 | 295 |
| 4 | 7/0.85 | 2.55 | 1.0 | 1.2 | 0.3 | 14.7 | 0.6 | 365 |
| 6 | 7/1.04 | 3.12 | 1.0 | 1.3 | 0.3 | 16.1 | 0.6 | 455 |
| 10 | 7/1.35 | 4.05 | 1.0 | 1.4 | 0.3 | 18.3 | 0.7 | 625 |
| 16 | 7/1.70 | 5.1 | 1.0 | 1.5 | 0.3 | 20.8 | 0.8 | 855 |
| 25 | 7/2.14 | 6.42 | 1.2 | 1.6 | 0.3 | 24.7 | 1.0 | 1240 |
| 35 | 7/2.52 | 7.56 | 1.2 | 1.7 | 0.3 | 27.4 | 1.1 | 1600 |
| 50 | 19/1.78 | 8.9 | 1.4 | 1.9 | 0.4 | 32.0 | 1.3 | 2200 |
| 70 | 19/2.14 | 10.7 | 1.6 | 2.1 | 0.4 | 37.6 | 1.5 | 3050 |
| 95 | 19/2.52 | 12.6 | 1.6 | 2.2 | 0.4 | 41.9 | 1.6 | 3980 |
| 120 | 37/2.03 | 14.2 | 1.6 | 2.4 | 0.4 | 45.8 | 1.7 | 4860 |
| 150 | 37/2.25 | 15.8 | 1.8 | 2.5 | 0.4 | 50.2 | 1.8 | 5870 |
| 185 | 37/2.52 | 17.6 | 2.0 | 2.7 | 0.4 | 55.5 | 1.9 | 7230 |
| 240 | 61/2.25 | 20.25 | 2.2 | 3.0 | 0.4 | 62.7 | 2.3 | 10100 |
0.6/1KV (FA-) TPYCY
| Conductor | Thick. of insulation | Thick. of bedding | Dia. of steel wire | Thick. of covering | (FA-) TPYCY | ||||
| Size | Construction | O.D | Nominal overall dia. | Tolerance | Cable weight (Approx.) | ||||
| mm² | No./mm | mm | mm | mm | mm | mm | mm | mm | Kg/Km |
| 1.5 | 7/0.53 | 1.59 | 1.0 | 1.2 | 0.3 | 0.9 | 14.5 | 0.6 | 300 |
| 2.5 | 7/0.67 | 2.01 | 1.0 | 1.2 | 0.3 | 0.9 | 15.5 | 0.6 | 355 |
| 4 | 7/0.85 | 2.55 | 1.0 | 1.2 | 0.3 | 1.0 | 16.9 | 0.7 | 440 |
| 6 | 7/1.04 | 3.12 | 1.0 | 1.3 | 0.3 | 1.0 | 18.3 | 0.7 | 535 |
| 10 | 7/1.35 | 4.05 | 1.0 | 1.4 | 0.3 | 1.1 | 20.7 | 0.8 | 725 |
| 16 | 7/1.70 | 5.1 | 1.0 | 1.5 | 0.3 | 1.1 | 23.2 | 0.9 | 970 |
| 25 | 7/2.14 | 6.42 | 1.2 | 1.6 | 0.3 | 1.2 | 27.3 | 1.1 | 1390 |
| 35 | 7/2.52 | 7.56 | 1.2 | 1.7 | 0.3 | 1.3 | 30.2 | 1.2 | 1770 |
| 50 | 19/1.78 | 8.9 | 1.4 | 1.9 | 0.4 | 1.4 | 35.0 | 1.4 | 2420 |
| 70 | 19/2.14 | 10.7 | 1.6 | 2.1 | 0.4 | 1.5 | 41.0 | 1.6 | 3350 |
| 95 | 19/2.52 | 12.6 | 1.6 | 2.2 | 0.4 | 1.6 | 45.5 | 1.7 | 4320 |
| 120 | 37/2.03 | 14.2 | 1.6 | 2.4 | 0.4 | 1.7 | 49.6 | 1.8 | 5250 |
| 150 | 37/2.25 | 15.8 | 1.8 | 2.5 | 0.4 | 1.9 | 54.2 | 1.9 | 6340 |
| 185 | 37/2.52 | 17.6 | 2.0 | 2.7 | 0.4 | 2.0 | 59.7 | 2.0 | 7780 |
| 240 | 61/2.25 | 20.25 | 2.2 | 3.0 | 0.4 | 2.2 | 67.2 | 3.4 | 10376 |
0.6/1KV (FA-) FPY
| Conductor | Thick. of insulation | Thick. of bedding | (FA-) FPY | ||||
| Size | Construction | O.D | Nominal overall dia. | Tolerance | Cable weight (Approx.) | ||
| mm² | No./mm | mm | mm | mm | mm | mm | Kg/Km |
| 1.5 | 7/0.53 | 1.59 | 1.0 | 1.2 | 11.8 | 0.6 | 230 |
| 2.5 | 7/0.67 | 2.01 | 1.0 | 1.2 | 12.8 | 0.6 | 290 |
| 4 | 7/0.85 | 2.55 | 1.0 | 1.3 | 14.4 | 0.7 | 380 |
| 6 | 7/1.04 | 3.12 | 1.0 | 1.3 | 15.8 | 0.8 | 500 |
| 10 | 7/1.35 | 4.05 | 1.0 | 1.4 | 18.3 | 0.9 | 730 |
| 16 | 7/1.70 | 5.1 | 1.0 | 1.5 | 21.0 | 1.1 | 1050 |
| 25 | 7/2.14 | 6.42 | 1.2 | 1.7 | 25.7 | 1.3 | 1590 |
| 35 | 7/2.52 | 7.56 | 1.2 | 1.8 | 28.6 | 1.4 | 2090 |
| 50 | 19/1.78 | 8.9 | 1.4 | 2.0 | 33.5 | 1.7 | 2810 |
| 70 | 19/2.14 | 10.7 | 1.4 | 2.1 | 38.1 | 1.9 | 3990 |
| 95 | 19/2.52 | 12.6 | 1.6 | 2.4 | 44.4 | 2.2 | 5300 |
| 120 | 37/2.03 | 14.2 | 1.6 | 2.5 | 48.7 | 2.4 | 6560 |
| 150 | 37/2.25 | 15.8 | 1.8 | 2.7 | 54.0 | 2.7 | 8010 |
| 185 | 37/2.52 | 17.6 | 2.0 | 2.9 | 59.8 | 3.0 | 9960 |
0.6/1KV (FA-) FPYC
| Conductor | Thick. of insulation | Thick. of bedding | Dia. of steel wire | (FA-) FPYC | ||||
| Size | Construction | O.D | Nominal overall dia. | Tolerance | Cable weight (Approx.) | |||
| mm² | No./mm | mm | mm | mm | mm | mm | mm | Kg / Km |
| 1.5 | 7/0.53 | 1.59 | 1.0 | 1.2 | 0.3 | 13.4 | 0.7 | 370 |
| 2.5 | 7/0.67 | 2.01 | 1.0 | 1.2 | 0.3 | 14.4 | 0.7 | 440 |
| 4 | 7/0.85 | 2.55 | 1.0 | 1.3 | 0.3 | 16.0 | 0.8 | 550 |
| 6 | 7/1.04 | 3.12 | 1.0 | 1.3 | 0.3 | 17.4 | 0.9 | 680 |
| 10 | 7/1.35 | 4.05 | 1.0 | 1.4 | 0.3 | 19.9 | 1.0 | 940 |
| 16 | 7/1.70 | 5.1 | 1.0 | 1.5 | 0.3 | 22.6 | 1.1 | 1280 |
| 25 | 7/2.14 | 6.42 | 1.2 | 1.7 | 0.3 | 27.3 | 1.4 | 1860 |
| 35 | 7/2.52 | 7.56 | 1.2 | 1.8 | 0.3 | 30.2 | 1.5 | 2400 |
| 50 | 19/1.78 | 8.9 | 1.4 | 2.0 | 0.4 | 35.6 | 1.8 | 3300 |
| 70 | 19/2.14 | 10.7 | 1.4 | 2.1 | 0.4 | 40.2 | 2.0 | 4580 |
| 95 | 19/2.52 | 12.6 | 1.6 | 2.4 | 0.4 | 46.5 | 2.3 | 5970 |
| 120 | 37/2.03 | 14.2 | 1.6 | 2.5 | 0.4 | 50.8 | 2.5 | 7290 |
| 150 | 37/2.25 | 15.8 | 1.8 | 2.7 | 0.4 | 56.1 | 2.8 | 8810 |
| 185 | 37/2.52 | 17.6 | 2.0 | 2.9 | 0.4 | 61.9 | 3.1 | 10850 |
0.6/1KV (FA-) FPYCY
| Conductor | Thick. of insulation | Thick. of bedding | Dia. of steel wire | Thick. of covering | (FA-) FPYCY | ||||
| Size | Construction | O.D | Nominal overall dia. | Tolerance | Cable weight (Approx.) | ||||
| mm² | No./mm | mm | mm | mm | mm | mm | mm | mm | Kg / Km |
| 1.5 | 7/0.53 | 1.59 | 1.0 | 1.2 | 0.3 | 0.9 | 15.4 | 0.8 | 450 |
| 2.5 | 7/0.67 | 2.01 | 1.0 | 1.2 | 0.3 | 1.0 | 16.4 | 0.8 | 530 |
| 4 | 7/0.85 | 2.55 | 1.0 | 1.3 | 0.3 | 1.0 | 18.1 | 0.9 | 660 |
| 6 | 7/1.04 | 3.12 | 1.0 | 1.3 | 0.3 | 1.0 | 19.6 | 1.0 | 800 |
| 10 | 7/1.35 | 4.05 | 1.0 | 1.4 | 0.3 | 1.1 | 22.2 | 1.1 | 1090 |
| 16 | 7/1.70 | 5.1 | 1.0 | 1.5 | 0.3 | 1.2 | 25.1 | 1.3 | 1460 |
| 25 | 7/2.14 | 6.42 | 1.2 | 1.7 | 0.3 | 1.3 | 30.0 | 1.5 | 2090 |
| 35 | 7/2.52 | 7.56 | 1.2 | 1.8 | 0.3 | 1.4 | 33.1 | 1.7 | 2660 |
| 50 | 19/1.78 | 8.9 | 1.4 | 2.0 | 0.4 | 1.5 | 38.8 | 1.9 | 3630 |
| 70 | 19/2.14 | 10.7 | 1.4 | 2.1 | 0.4 | 1.6 | 43.6 | 2.2 | 5030 |
| 95 | 19/2.52 | 12.6 | 1.6 | 2.4 | 0.4 | 1.8 | 50.2 | 2.5 | 6480 |
| 120 | 37/2.03 | 14.2 | 1.6 | 2.5 | 0.4 | 1.9 | 54.8 | 2.7 | 7880 |
| 150 | 37/2.25 | 15.8 | 1.8 | 2.7 | 0.4 | 2.0 | 60.4 | 3.0 | 9510 |
| 185 | 37/2.52 | 17.6 | 2.0 | 2.9 | 0.4 | 2.1 | 66.5 | 3.3 | 11670 |
0.6/1KV (FA-) 5PY
| Conductor | Thick. of insulation | Thick. of bedding | (FA-) 5PY | ||||
| Size | Construction | O.D | Nominal overall dia. | Tolerance | Cable weight (Approx.) | ||
| mm² | No./mm | mm | mm | mm | mm | mm | Kg / Km |
| 1.5 | 7/0.53 | 1.59 | 1.0 | 1.2 | 12.8 | 0.6 | 270 |
| 2.5 | 7/0.67 | 2.01 | 1.0 | 1.3 | 14.2 | 0.7 | 340 |
| 4 | 7/0.85 | 2.55 | 1.0 | 1.3 | 15.7 | 0.8 | 440 |
| 6 | 7/1.04 | 3.12 | 1.0 | 1.4 | 17.5 | 0.9 | 570 |
| 10 | 7/1.35 | 4.05 | 1.0 | 1.5 | 20.2 | 1.0 | 840 |
| 16 | 7/1.70 | 5.1 | 1.0 | 1.6 | 23.2 | 1.2 | 1200 |
| 25 | 7/2.14 | 6.42 | 1.2 | 1.8 | 28.4 | 1.4 | 1820 |
| 35 | 7/2.52 | 7.56 | 1.2 | 1.9 | 31.7 | 1.6 | 2390 |
| 50 | 19/1.78 | 8.9 | 1.4 | 2.1 | 37.1 | 1.9 | 3210 |
| 70 | 19/2.14 | 10.7 | 1.4 | 2.3 | 42.4 | 2.1 | 4550 |
| 95 | 19/2.52 | 12.6 | 1.6 | 2.6 | 49.6 | 2.5 | 6050 |
| 120 | 37/2.03 | 14.2 | 1.6 | 2.7 | 54.1 | 2.7 | 7480 |
| 150 | 37/2.25 | 15.8 | 1.8 | 3.0 | 60.2 | 3.0 | 9140 |
| 185 | 37/2.52 | 17.6 | 2.0 | 3.2 | 66.6 | 3.3 | 11360 |
0.6/1KV (FA-) 5PYC
| Conductor | Thick. of insulation | Thick. of bedding | Dia. of steel wire | (FA-) 5PYC | ||||
| Size | Construction | O.D | Nominal overall dia. | Tolerance | Cable weight (Approx.) | |||
| mm² | No./mm | mm | mm | mm | mm | mm | mm | Kg / Km |
| 1.5 | 7/0.53 | 1.59 | 1.0 | 1.2 | 0.3 | 14.4 | 0.7 | 430 |
| 2.5 | 7/0.67 | 2.01 | 1.0 | 1.3 | 0.3 | 15.8 | 0.8 | 510 |
| 4 | 7/0.85 | 2.55 | 1.0 | 1.3 | 0.3 | 17.3 | 0.9 | 630 |
| 6 | 7/1.04 | 3.12 | 1.0 | 1.4 | 0.3 | 19.1 | 1.0 | 780 |
| 10 | 7/1.35 | 4.05 | 1.0 | 1.5 | 0.3 | 21.8 | 1.1 | 1080 |
| 16 | 7/1.70 | 5.1 | 1.0 | 1.6 | 0.3 | 24.8 | 1.2 | 1460 |
| 25 | 7/2.14 | 6.42 | 1.2 | 1.8 | 0.3 | 30.0 | 1.5 | 2130 |
| 35 | 7/2.52 | 7.56 | 1.2 | 1.9 | 0.4 | 33.8 | 1.7 | 2740 |
| 50 | 19/1.78 | 8.9 | 1.4 | 2.1 | 0.4 | 39.2 | 2.0 | 3770 |
| 70 | 19/2.14 | 10.7 | 1.4 | 2.3 | 0.4 | 44.5 | 2.2 | 5230 |
| 95 | 19/2.52 | 12.6 | 1.6 | 2.6 | 0.4 | 51.7 | 2.6 | 6810 |
| 120 | 37/2.03 | 14.2 | 1.6 | 2.7 | 0.4 | 56.2 | 2.8 | 8320 |
| 150 | 37/2.25 | 15.8 | 1.8 | 3.0 | 0.4 | 62.3 | 3.1 | 10050 |
| 185 | 37/2.52 | 17.6 | 2.0 | 3.2 | 0.4 | 68.7 | 3.4 | 12370 |
0.6/1KV (FA-) 5PYCY
| Conductor | Thick. of insulation | Thick. of bedding | Dia. of steel wire | Thick. of covering | (FA-) 5PYCY | ||||
| Size | Construction | O.D | Nominal overall dia. | Tolerance | Cable weight (Approx.) | ||||
| mm² | No./mm | mm | mm | mm | mm | mm | mm | mm | Kg / Km |
| 1.5 | 7/0.53 | 1.59 | 1.0 | 1.2 | 0.3 | 1.0 | 16.5 | 0.8 | 520 |
| 2.5 | 7/0.67 | 2.01 | 1.0 | 1.3 | 0.3 | 1.0 | 17.9 | 0.9 | 610 |
| 4 | 7/0.85 | 2.55 | 1.0 | 1.3 | 0.3 | 1.0 | 19.4 | 1.0 | 760 |
| 6 | 7/1.04 | 3.12 | 1.0 | 1.4 | 0.3 | 1.1 | 21.5 | 1.1 | 920 |
| 10 | 7/1.35 | 4.05 | 1.0 | 1.5 | 0.3 | 1.1 | 24.2 | 1.2 | 1250 |
| 16 | 7/1.70 | 5.1 | 1.0 | 1.6 | 0.3 | 1.2 | 27.4 | 1.4 | 1670 |
| 25 | 7/2.14 | 6.42 | 1.2 | 1.8 | 0.3 | 1.4 | 33.0 | 1.7 | 2390 |
| 35 | 7/2.52 | 7.56 | 1.2 | 1.9 | 0.4 | 1.4 | 36.8 | 1.8 | 3040 |
| 50 | 19/1.78 | 8.9 | 1.4 | 2.1 | 0.4 | 1.6 | 42.6 | 2.1 | 4140 |
| 70 | 19/2.14 | 10.7 | 1.4 | 2.3 | 0.4 | 1.7 | 48.1 | 2.4 | 5740 |
| 95 | 19/2.52 | 12.6 | 1.6 | 2.6 | 0.4 | 1.9 | 55.8 | 2.8 | 7390 |
| 120 | 37/2.03 | 14.2 | 1.6 | 2.7 | 0.4 | 2.0 | 60.5 | 3.0 | 8990 |
| 150 | 37/2.25 | 15.8 | 1.8 | 3.0 | 0.4 | 2.2 | 67.0 | 3.4 | 10850 |
| 185 | 37/2.52 | 17.6 | 2.0 | 3.2 | 0.4 | 2.3 | 73.6 | 3.7 | 13310 |
0.6/1KV (FA-) 6PY
| Conductor | Thick. of insulation | Thick. of bedding | (FA-) 6PY | ||||
| Size | Construction | O.D | Nominal overall dia. | Tolerance | Cable weight (Approx.) | ||
| mm² | No./mm | mm | mm | mm | mm | mm | Kg / Km |
| 1.5 | 7/0.53 | 1.59 | 1.0 | 1.3 | 14.1 | 0.7 | 310 |
| 2.5 | 7/0.67 | 2.01 | 1.0 | 1.3 | 15.4 | 0.8 | 390 |
| 4 | 7/0.85 | 2.55 | 1.0 | 1.4 | 17.3 | 0.9 | 510 |
| 6 | 7/1.04 | 3.12 | 1.0 | 1.4 | 19.0 | 1.0 | 650 |
| 10 | 7/1.35 | 4.05 | 1.0 | 1.6 | 22.2 | 1.1 | 960 |
| 16 | 7/1.70 | 5.1 | 1.0 | 1.7 | 25.6 | 1.3 | 1370 |
| 25 | 7/2.14 | 6.42 | 1.2 | 1.9 | 31.3 | 1.6 | 2080 |
| 35 | 7/2.52 | 7.56 | 1.2 | 2.0 | 34.9 | 1.7 | 2730 |
| 50 | 19/1.78 | 8.9 | 1.4 | 2.2 | 40.9 | 2.0 | 3660 |
| 70 | 19/2.14 | 10.7 | 1.4 | 2.5 | 47.0 | 2.4 | 5190 |
| 95 | 19/2.52 | 12.6 | 1.6 | 2.8 | 54.9 | 2.7 | 6900 |
| 120 | 37/2.03 | 14.2 | 1.6 | 2.9 | 59.9 | 3.0 | 8530 |
| 150 | 37/2.25 | 15.8 | 1.8 | 3.2 | 66.5 | 3.3 | 10420 |
| 185 | 37/2.52 | 17.6 | 2.0 | 3.5 | 73.9 | 3.7 | 12960 |
0.6/1KV (FA-) 6PYC
| Conductor | Thick. of insulation | Thick. of bedding | Dia. of steel wire | (FA-) 6PYC | ||||
| Size | Construction | O.D | Nominal overall dia. | Tolerance | Cable weight (Approx.) | |||
| mm² | No./mm | mm | mm | mm | mm | mm | mm | Kg / Km |
| 1.5 | 7/0.53 | 1.59 | 1.0 | 1.3 | 0.3 | 15.7 | 0.8 | 500 |
| 2.5 | 7/0.67 | 2.01 | 1.0 | 1.3 | 0.3 | 17.0 | 0.9 | 590 |
| 4 | 7/0.85 | 2.55 | 1.0 | 1.4 | 0.3 | 18.9 | 0.9 | 720 |
| 6 | 7/1.04 | 3.12 | 1.0 | 1.4 | 0.3 | 20.6 | 1.0 | 890 |
| 10 | 7/1.35 | 4.05 | 1.0 | 1.6 | 0.3 | 23.8 | 1.2 | 1240 |
| 16 | 7/1.70 | 5.1 | 1.0 | 1.7 | 0.3 | 27.2 | 1.4 | 1670 |
| 25 | 7/2.14 | 6.42 | 1.2 | 1.9 | 0.3 | 32.9 | 1.6 | 2430 |
| 35 | 7/2.52 | 7.56 | 1.2 | 2.0 | 0.4 | 37.0 | 1.9 | 3130 |
| 50 | 19/1.78 | 8.9 | 1.4 | 2.2 | 0.4 | 43.0 | 2.2 | 4300 |
| 70 | 19/2.14 | 10.7 | 1.4 | 2.5 | 0.4 | 49.1 | 2.5 | 5970 |
| 95 | 19/2.52 | 12.6 | 1.6 | 2.8 | 0.4 | 57.0 | 2.9 | 7770 |
| 120 | 37/2.03 | 14.2 | 1.6 | 2.9 | 0.4 | 62.0 | 3.1 | 9490 |
| 150 | 37/2.25 | 15.8 | 1.8 | 3.2 | 0.4 | 68.6 | 3.4 | 11460 |
| 185 | 37/2.52 | 17.6 | 2.0 | 3.5 | 0.4 | 76.0 | 3.8 | 14110 |
0.6/1KV (FA-) 6PYCY
| Conductor | Thick. of insulation | Thick. of bedding | Dia. of steel wire | Thick. of covering | (FA-) 6PYCY | ||||
| Size | Construction | O.D | Nominal overall dia. | Tolerance | Cable weight (Approx.) | ||||
| mm² | No./mm | mm | mm | mm | mm | mm | mm | mm | Kg / Km |
| 1.5 | 7/0.53 | 1.59 | 1.0 | 1.3 | 0.3 | 1.0 | 17.8 | 0.9 | 600 |
| 2.5 | 7/0.67 | 2.01 | 1.0 | 1.3 | 0.3 | 1.0 | 19.1 | 1.0 | 700 |
| 4 | 7/0.85 | 2.55 | 1.0 | 1.4 | 0.3 | 1.1 | 21.3 | 1.1 | 870 |
| 6 | 7/1.04 | 3.12 | 1.0 | 1.4 | 0.3 | 1.1 | 23.0 | 1.2 | 1050 |
| 10 | 7/1.35 | 4.05 | 1.0 | 1.6 | 0.3 | 1.2 | 26.4 | 1.3 | 1430 |
| 16 | 7/1.70 | 5.1 | 1.0 | 1.7 | 0.3 | 1.3 | 30.0 | 1.5 | 1910 |
| 25 | 7/2.14 | 6.42 | 1.2 | 1.9 | 0.3 | 1.4 | 35.9 | 1.8 | 2730 |
| 35 | 7/2.52 | 7.56 | 1.2 | 2.0 | 0.4 | 1.5 | 40.2 | 2.0 | 3470 |
| 50 | 19/1.78 | 8.9 | 1.4 | 2.2 | 0.4 | 1.7 | 46.6 | 2.3 | 4720 |
| 70 | 19/2.14 | 10.7 | 1.4 | 2.5 | 0.4 | 1.8 | 53.0 | 2.7 | 6550 |
| 95 | 19/2.52 | 12.6 | 1.6 | 2.8 | 0.4 | 2.0 | 61.3 | 3.1 | 8430 |
| 120 | 37/2.03 | 14.2 | 1.6 | 2.9 | 0.4 | 2.2 | 66.7 | 3.3 | 10250 |
| 150 | 37/2.25 | 15.8 | 1.8 | 3.2 | 0.4 | 2.3 | 73.5 | 3.7 | 12370 |
| 185 | 37/2.52 | 17.6 | 2.0 | 3.5 | 0.4 | 2.5 | 81.4 | 4.1 | 15180 |
[FA-] SPYCS, SPYCBS, DPYCS, TPYCS, FPYCSSTANDARDS
IEC 60332-3 Cat.A(for FA-type)
CABLE CONSTRUCTION
Cable Parameter
0.6/1KV (FA-) SPYCS, SPYCBS
0.6/1KV (FA-) SPYCYS, SPYCBYS
0.6/1KV (FA-) DPYCS
0.6/1KV (FA-) DPYCYS
0.6/1KV (FA-) TPYCS
0.6/1KV (FA-) TPYCYS
0.6/1KV (FA-) FPYCS
0.6/1KV (FA-) FPYCYS
STANDARDS
JISC 3410-1999
IEC 60332-1
IEC 60332-3 Cat.A(for FA-type)
CABLE CONSTRUCTION
| Conductor | S(D,T) | Tinned annealed stranded copper, class 2 according to IEC 60228 |
| Insulation | P | 85°C EPR as per JIS C 3401 |
| Cabling |
Insulated conductors shall be cabled. Flame retardant & non-hygroscopic fillers may be used. |
|
| Overall Shield | S | Tinned copper wire braid |
| Bedding | Y | PVC as per JIS C 3401 |
| Armor | C (CB) | Galvanized steel wire braid(-C TYPE) or copper alloy wire raid(-CB TYPE) |
| Sheath | Y | PVC as per JIS C 3401 |
| Core identification |
1C Black 2C Black, White 3C Black, White, Red |
|
| Outer sheath color | Black |
Cable Parameter
0.6/1KV (FA-) SPYCS, SPYCBS
| Conductor | Thick. of insul- ation | Dia. of shield wire | Thick. of bedding | Dia. over bedding | Dia. of armor wire | (FA-) SPYCS, SPYCBS | ||||
| Size | Construction | O.D | Nom. overall dia. | Tolerance | Cable weight | |||||
| mm² | No./mm | mm | mm | mm | mm | mm | mm | mm | mm | Kg/Km |
| 1.5 | 7/0.53 | 1.59 | 1 | 0.12 | 1 | 6.4 | 0.3 | 8 | 0.4 | 110 |
| 2.5 | 7/0.67 | 2.01 | 1 | 0.12 | 1 | 6.9 | 0.3 | 8.5 | 0.4 | 130 |
| 4 | 7/0.85 | 2.55 | 1 | 0.12 | 1 | 7.5 | 0.3 | 9.1 | 0.5 | 150 |
| 6 | 7/1.04 | 3.12 | 1 | 0.14 | 1 | 8.1 | 0.3 | 9.7 | 0.5 | 180 |
| 10 | 7/1.35 | 4.05 | 1 | 0.14 | 1.1 | 9.4 | 0.3 | 11 | 0.6 | 240 |
| 16 | 7/1.70 | 5.1 | 1 | 0.14 | 1.1 | 10.4 | 0.3 | 12 | 0.6 | 320 |
| 25 | 7/2.14 | 6.42 | 1.2 | 0.14 | 1.2 | 12.3 | 0.3 | 13.9 | 0.7 | 450 |
| 35 | 7/2.52 | 7.56 | 1.2 | 0.16 | 1.2 | 13.6 | 0.3 | 15.2 | 0.8 | 550 |
| 50 | 19/1.78 | 8.9 | 1.4 | 0.16 | 1.3 | 15.7 | 0.3 | 17.3 | 0.9 | 710 |
| 70 | 19/2.14 | 10.7 | 1.6 | 0.16 | 1.4 | 18.1 | 0.3 | 19.7 | 1 | 980 |
| 95 | 19/2.52 | 12.6 | 1.6 | 0.16 | 1.5 | 20.3 | 0.3 | 21.9 | 1.1 | 1280 |
| 120 | 37/2.03 | 14.2 | 1.6 | 0.18 | 1.6 | 22.2 | 0.3 | 23.8 | 1.2 | 1570 |
| 150 | 37/2.25 | 15.8 | 1.8 | 0.18 | 1.6 | 24.2 | 0.3 | 25.8 | 1.3 | 1900 |
| 185 | 37/2.52 | 17.6 | 2 | 0.18 | 1.7 | 26.6 | 0.3 | 28.2 | 1.4 | 2310 |
| 240 | 61/2.25 | 20.3 | 2.2 | 0.2 | 1.8 | 30.1 | 0.4 | 32.2 | 1.6 | 2980 |
| 300 | 61/2.52 | 22.7 | 2.4 | 0.2 | 2 | 33.4 | 0.4 | 35.5 | 1.8 | 3750 |
0.6/1KV (FA-) SPYCYS, SPYCBYS
| Conductor | Thick. of insulation | Dia. of shield wire | Thick. of bedding | Dia. over bedding | Dia. of armor wire | Thick. of covering | (FA-) SPYCYS, SPYCBYS | ||||
| Size | Construction | O.D | Nom. overall dia. | Tolerance | Cable weight | ||||||
| mm² | No./mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | Kg/Km |
| 1.5 | 7/0.53 | 1.59 | 1 | 0.12 | 1 | 6.4 | 0.3 | 0.8 | 9.9 | 0.5 | 150 |
| 2.5 | 7/0.67 | 2.01 | 1 | 0.12 | 1 | 6.9 | 0.3 | 0.8 | 10.6 | 0.5 | 160 |
| 4 | 7/0.85 | 2.55 | 1 | 0.12 | 1 | 7.5 | 0.3 | 0.8 | 11.2 | 0.6 | 185 |
| 6 | 7/1.04 | 3.12 | 1 | 0.14 | 1 | 8.1 | 0.3 | 0.8 | 12.1 | 0.6 | 220 |
| 10 | 7/1.35 | 4.05 | 1 | 0.14 | 1.1 | 9.4 | 0.3 | 0.9 | 13.4 | 0.7 | 280 |
| 16 | 7/1.70 | 5.1 | 1 | 0.14 | 1.1 | 10.4 | 0.3 | 0.9 | 14.6 | 0.7 | 370 |
| 25 | 7/2.14 | 6.42 | 1.2 | 0.14 | 1.2 | 12.3 | 0.3 | 0.9 | 16.5 | 0.8 | 500 |
| 35 | 7/2.52 | 7.56 | 1.2 | 0.16 | 1.2 | 13.6 | 0.3 | 1 | 18 | 0.9 | 620 |
| 50 | 19/1.78 | 8.9 | 1.4 | 0.16 | 1.3 | 15.7 | 0.3 | 1 | 20.3 | 1 | 790 |
| 70 | 19/2.14 | 10.7 | 1.6 | 0.16 | 1.4 | 18.1 | 0.3 | 1.1 | 22.9 | 1.1 | 1100 |
| 95 | 19/2.52 | 12.6 | 1.6 | 0.16 | 1.5 | 20.3 | 0.3 | 1.1 | 21.9 | 1.1 | 1400 |
| 120 | 37/2.03 | 14.2 | 1.6 | 0.18 | 1.6 | 22.2 | 0.3 | 1.2 | 23.8 | 1.2 | 1700 |
| 150 | 37/2.25 | 15.8 | 1.8 | 0.18 | 1.6 | 24.2 | 0.3 | 1.2 | 25.8 | 1.3 | 2020 |
| 185 | 37/2.52 | 17.6 | 2 | 0.18 | 1.7 | 26.6 | 0.3 | 1.3 | 28.2 | 1.4 | 2500 |
| 240 | 61/2.25 | 20.3 | 2.2 | 0.2 | 1.8 | 30.1 | 0.4 | 1.4 | 32.2 | 1.6 | 3200 |
| 300 | 61/2.52 | 22.7 | 2.4 | 0.2 | 2 | 33.4 | 0.4 | 1.5 | 35.5 | 1.8 | 4000 |
0.6/1KV (FA-) DPYCS
| Conductor | Thick. of insulation | Dia. of shield wire | Thick. of bedding | Dia. over bedding | Dia. of steel wire | (FA-) DPYCS | ||||
| Size | Construction | O.D | Nom. overall dia. | Tolerance | Cable weight | |||||
| mm² | No./mm | mm | mm | mm | mm | mm | mm | mm | mm | Kg/Km |
| 1.5 | 7/0.53 | 1.59 | 1.0 | 0.14 | 1.2 | 11.3 | 0.3 | 12.6 | 0.5 | 265 |
| 2.5 | 7/0.67 | 2.01 | 1.0 | 0.14 | 1.2 | 12.2 | 0.3 | 13.5 | 0.5 | 310 |
| 4 | 7/0.85 | 2.55 | 1.0 | 0.16 | 1.2 | 13.4 | 0.3 | 14.7 | 0.6 | 380 |
| 6 | 7/1.04 | 3.12 | 1.0 | 0.16 | 1.3 | 14.4 | 0.3 | 15.9 | 0.8 | 460 |
| 10 | 7/1.35 | 4.05 | 1.0 | 0.16 | 1.3 | 16.4 | 0.3 | 18.0 | 0.9 | 610 |
| 16 | 7/1.70 | 5.1 | 1.0 | 0.16 | 1.4 | 18.7 | 0.3 | 20.2 | 1.0 | 790 |
| 25 | 7/2.14 | 6.42 | 1.2 | 0.18 | 1.6 | 22.5 | 0.3 | 24.1 | 1.2 | 1100 |
| 35 | 7/2.52 | 7.56 | 1.2 | 0.18 | 1.7 | 25.0 | 0.3 | 26.6 | 1.3 | 1400 |
| 50 | 19/1.78 | 8.9 | 1.4 | 0.18 | 1.8 | 29.1 | 0.3 | 30.6 | 1.5 | 1800 |
| 70 | 19/2.14 | 10.7 | 1.6 | 0.2 | 2.0 | 34.0 | 0.4 | 36.1 | 1.8 | 2640 |
| 95 | 19/2.52 | 12.6 | 1.6 | 0.26 | 2.2 | 38.7 | 0.4 | 40.7 | 2.0 | 3410 |
| 120 | 37/2.03 | 14.2 | 1.6 | 0.26 | 2.3 | 42.1 | 0.4 | 44.2 | 2.2 | 3900 |
| 150 | 37/2.25 | 15.8 | 1.8 | 0.18 | 1.6 | 24.2 | 0.3 | 25.8 | 1.3 | 1900 |
| 185 | 37/2.52 | 17.6 | 2 | 0.18 | 1.7 | 26.6 | 0.3 | 28.2 | 1.4 | 2310 |
| 240 | 61/2.25 | 20.3 | 2.2 | 0.2 | 1.8 | 30.1 | 0.4 | 32.2 | 1.6 | 2980 |
| 300 | 61/2.52 | 22.7 | 2.4 | 0.2 | 2 | 33.4 | 0.4 | 35.5 | 1.8 | 3750 |
0.6/1KV (FA-) DPYCYS
| Conductor | Thick. of insulation | Dia. of shield wire | Thick. of bedding | Dia. over bedding | Dia. of steel wire | Thick. of covering | (FA-) DPYCYS | ||||
| Size | Construction | O.D | Nom. overall dia. | Tolerance | Cable weight | ||||||
| mm² | No./mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | Kg/Km |
| 1.5 | 7/0.53 | 1.59 | 1.0 | 0.14 | 1.2 | 11.3 | 0.3 | 0.9 | 14.6 | 0.6 | 325 |
| 2.5 | 7/0.67 | 2.01 | 1.0 | 0.14 | 1.2 | 12.2 | 0.3 | 0.9 | 15.5 | 0.6 | 375 |
| 4 | 7/0.85 | 2.55 | 1.0 | 0.16 | 1.2 | 13.4 | 0.3 | 1.0 | 16.9 | 0.7 | 455 |
| 6 | 7/1.04 | 3.12 | 1.0 | 0.16 | 1.3 | 14.4 | 0.3 | 1.0 | 18.1 | 0.9 | 550 |
| 10 | 7/1.35 | 4.05 | 1.0 | 0.16 | 1.3 | 16.4 | 0.3 | 1.0 | 20.2 | 1.0 | 710 |
| 16 | 7/1.70 | 5.1 | 1.0 | 0.16 | 1.4 | 18.7 | 0.3 | 1.1 | 22.6 | 1.1 | 910 |
| 25 | 7/2.14 | 6.42 | 1.2 | 0.18 | 1.6 | 22.5 | 0.3 | 1.2 | 26.7 | 1.3 | 1290 |
| 35 | 7/2.52 | 7.56 | 1.2 | 0.18 | 1.7 | 25.0 | 0.3 | 1.3 | 29.3 | 1.5 | 1620 |
| 50 | 19/1.78 | 8.9 | 1.4 | 0.18 | 1.8 | 29.1 | 0.3 | 1.4 | 33.6 | 1.7 | 2030 |
| 70 | 19/2.14 | 10.7 | 1.6 | 0.2 | 2.0 | 34.0 | 0.4 | 1.5 | 39.3 | 2.0 | 2900 |
| 95 | 19/2.52 | 12.6 | 1.6 | 0.26 | 2.2 | 38.7 | 0.4 | 1.6 | 44.2 | 2.2 | 3700 |
| 120 | 37/2.03 | 14.2 | 1.6 | 0.26 | 2.3 | 42.1 | 0.4 | 1.7 | 47.9 | 2.4 | 4320 |
| 150 | 37/2.25 | 15.8 | 1.8 | 0.18 | 1.6 | 24.2 | 0.3 | 1.2 | 25.8 | 1.3 | 2020 |
| 185 | 37/2.52 | 17.6 | 2 | 0.18 | 1.7 | 26.6 | 0.3 | 1.3 | 28.2 | 1.4 | 2500 |
| 240 | 61/2.25 | 20.3 | 2.2 | 0.2 | 1.8 | 30.1 | 0.4 | 1.4 | 32.2 | 1.6 | 3200 |
| 300 | 61/2.52 | 22.7 | 2.4 | 0.2 | 2 | 33.4 | 0.4 | 1.5 | 35.5 | 1.8 | 4000 |
0.6/1KV (FA-) TPYCS
| Conductor | Thick. of insulation | Dia. of shield wire | Thick. of bedding | Dia. over bedding | Dia. of steel wire | (FA-) TPYCS | ||||
| Size | Construction | O.D | Nom. overall dia. | Tolerance | Cable weight | |||||
| mm² | No./mm | mm | mm | mm | mm | mm | mm | mm | mm | Kg/Km |
| 1.5 | 7/0.53 | 1.59 | 1.0 | 0.14 | 1.2 | 11.9 | 0.3 | 13.2 | 0.5 | 305 |
| 2.5 | 7/0.67 | 2.01 | 1.0 | 0.14 | 1.2 | 12.9 | 0.3 | 14.2 | 0.6 | 360 |
| 4 | 7/0.85 | 2.55 | 1.0 | 0.16 | 1.3 | 14.4 | 0.3 | 15.7 | 0.6 | 455 |
| 6 | 7/1.04 | 3.12 | 1.0 | 0.16 | 1.3 | 15.3 | 0.3 | 16.8 | 0.8 | 530 |
| 10 | 7/1.35 | 4.05 | 1.0 | 0.16 | 1.4 | 17.5 | 0.3 | 19.0 | 1.0 | 730 |
| 16 | 7/1.70 | 5.1 | 1.0 | 0.16 | 1.5 | 19.8 | 0.3 | 21.4 | 1.1 | 990 |
| 25 | 7/2.14 | 6.42 | 1.2 | 0.18 | 1.6 | 24.0 | 0.3 | 25.6 | 1.3 | 1400 |
| 35 | 7/2.52 | 7.56 | 1.2 | 0.18 | 1.7 | 26.7 | 0.3 | 28.2 | 1.4 | 1850 |
| 50 | 19/1.78 | 8.9 | 1.4 | 0.2 | 1.9 | 31.1 | 0.3 | 32.7 | 1.6 | 2450 |
| 70 | 19/2.14 | 10.7 | 1.6 | 0.26 | 2.1 | 36.6 | 0.4 | 38.7 | 1.9 | 3350 |
| 95 | 19/2.52 | 12.6 | 1.6 | 0.26 | 2.3 | 41.3 | 0.4 | 43.4 | 2.2 | 4390 |
| 120 | 37/2.03 | 14.2 | 1.6 | 0.26 | 2.4 | 45.0 | 0.4 | 47.1 | 2.4 | 5350 |
| 150 | 37/2.25 | 15.8 | 1.8 | 0.26 | 2.6 | 49.8 | 0.4 | 51.8 | 2.6 | 6100 |
| 185 | 37/2.52 | 17.6 | 2.0 | 0.26 | 2.8 | 54.9 | 0.4 | 57.0 | 2.9 | 7530 |
0.6/1KV (FA-) TPYCYS
| Conductor | Thick. of insulation | Dia. of shield wire | Thick. of bedding | Dia. over bedding | Dia. of steel wire | Thick. of covering | (FA-) TPYCYS | ||||
| Size | Construction | O.D | Nom. overall dia. | Tolerance | Cable weight | ||||||
| mm² | No./mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | Kg/Km |
| 1.5 | 7/0.53 | 1.59 | 1.0 | 0.14 | 1.2 | 11.9 | 0.3 | 0.9 | 15.2 | 0.6 | 365 |
| 2.5 | 7/0.67 | 2.01 | 1.0 | 0.14 | 1.2 | 12.9 | 0.3 | 1.0 | 16.4 | 0.7 | 430 |
| 4 | 7/0.85 | 2.55 | 1.0 | 0.16 | 1.3 | 14.4 | 0.3 | 1.0 | 17.9 | 0.7 | 535 |
| 6 | 7/1.04 | 3.12 | 1.0 | 0.16 | 1.3 | 15.3 | 0.3 | 1.0 | 18.9 | 1.0 | 610 |
| 10 | 7/1.35 | 4.05 | 1.0 | 0.16 | 1.4 | 17.5 | 0.3 | 1.1 | 21.4 | 1.1 | 830 |
| 16 | 7/1.70 | 5.1 | 1.0 | 0.16 | 1.5 | 19.8 | 0.3 | 1.1 | 23.8 | 1.2 | 1100 |
| 25 | 7/2.14 | 6.42 | 1.2 | 0.18 | 1.6 | 24.0 | 0.3 | 1.2 | 28.2 | 1.4 | 1550 |
| 35 | 7/2.52 | 7.56 | 1.2 | 0.18 | 1.7 | 26.7 | 0.3 | 1.3 | 31.0 | 1.6 | 2020 |
| 50 | 19/1.78 | 8.9 | 1.4 | 0.2 | 1.9 | 31.1 | 0.3 | 1.4 | 35.7 | 1.8 | 2670 |
| 70 | 19/2.14 | 10.7 | 1.6 | 0.26 | 2.1 | 36.6 | 0.4 | 1.6 | 42.1 | 2.1 | 3650 |
| 95 | 19/2.52 | 12.6 | 1.6 | 0.26 | 2.3 | 41.3 | 0.4 | 1.7 | 47.0 | 2.3 | 4730 |
| 120 | 37/2.03 | 14.2 | 1.6 | 0.26 | 2.4 | 45.0 | 0.4 | 1.8 | 50.9 | 2.5 | 5740 |
| 150 | 37/2.25 | 15.8 | 1.8 | 0.26 | 2.6 | 49.8 | 0.4 | 1.9 | 55.9 | 2.8 | 6570 |
| 185 | 37/2.52 | 17.6 | 2.0 | 0.26 | 2.8 | 54.9 | 0.4 | 2.0 | 61.3 | 3.1 | 8080 |
0.6/1KV (FA-) FPYCS
| Conductor | Thick. of insulation | Dia. of shield wire | Thick. of bedding | Dia. over bedding | Dia. of steel wire | (FA-) FPYCS | ||||
| Size | Construction | O.D | Nom. overall dia. | Tolerance | Cable weight | |||||
| mm² | No./mm | mm | mm | mm | mm | mm | mm | mm | mm | Kg/Km |
| 1.5 | 7/0.53 | 1.59 | 1.0 | 0.14 | 1.2 | 12.4 | 0.3 | 14.0 | 0.7 | 400 |
| 2.5 | 7/0.67 | 2.01 | 1.0 | 0.16 | 1.2 | 13.7 | 0.3 | 15.3 | 0.8 | 480 |
| 4 | 7/0.85 | 2.55 | 1.0 | 0.16 | 1.3 | 15.1 | 0.3 | 16.7 | 0.8 | 600 |
| 6 | 7/1.04 | 3.12 | 1.0 | 0.16 | 1.4 | 16.7 | 0.3 | 18.3 | 0.9 | 740 |
| 10 | 7/1.35 | 4.05 | 1.0 | 0.16 | 1.4 | 19.1 | 0.3 | 20.7 | 1.0 | 1030 |
| 16 | 7/1.70 | 5.1 | 1.0 | 0.18 | 1.5 | 22.0 | 0.3 | 23.6 | 1.2 | 1350 |
| 25 | 7/2.14 | 6.42 | 1.2 | 0.18 | 1.7 | 26.5 | 0.3 | 28.1 | 1.4 | 1950 |
| 35 | 7/2.52 | 7.56 | 1.2 | 0.18 | 1.8 | 29.5 | 0.3 | 31.1 | 1.6 | 2540 |
| 50 | 19/1.78 | 8.9 | 1.4 | 0.20 | 2.0 | 34.5 | 0.4 | 36.6 | 1.8 | 3480 |
| 70 | 19/2.14 | 10.7 | 1.4 | 0.26 | 2.2 | 39.5 | 0.4 | 41.6 | 2.1 | 4750 |
| 95 | 19/2.52 | 12.6 | 1.6 | 0.26 | 2.4 | 45.9 | 0.4 | 48.0 | 2.4 | 6280 |
| 120 | 37/2.03 | 14.2 | 1.6 | 0.26 | 2.6 | 50.1 | 0.4 | 52.1 | 2.6 | 7590 |
| 150 | 37/2.25 | 15.8 | 1.8 | 0.26 | 2.8 | 55.3 | 0.4 | 57.4 | 2.9 | 9150 |
| 185 | 37/2.52 | 17.6 | 2.0 | 0.26 | 3.0 | 61.2 | 0.4 | 63.2 | 3.2 | 11150 |
0.6/1KV (FA-) FPYCYS
| Conductor | Thick. of insulation | Dia. of shield wire | Thick. of bedding | Dia. over bedding | Dia. of steel wire | Thick. of covering | (FA-) TPYCYS | ||||
| Size | Construction | O.D | Nom. overall dia. | Tolerance | Cable weight | ||||||
| mm² | No./mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | Kg/Km |
| 1.5 | 7/0.53 | 1.59 | 1.0 | 0.14 | 1.2 | 12.4 | 0.3 | 1.0 | 16.0 | 0.8 | 490 |
| 2.5 | 7/0.67 | 2.01 | 1.0 | 0.16 | 1.2 | 13.7 | 0.3 | 1.0 | 17.4 | 0.9 | 580 |
| 4 | 7/0.85 | 2.55 | 1.0 | 0.16 | 1.3 | 15.1 | 0.3 | 1.0 | 18.9 | 0.9 | 720 |
| 6 | 7/1.04 | 3.12 | 1.0 | 0.16 | 1.4 | 16.7 | 0.3 | 1.1 | 20.5 | 1.0 | 880 |
| 10 | 7/1.35 | 4.05 | 1.0 | 0.16 | 1.4 | 19.1 | 0.3 | 1.1 | 23.1 | 1.2 | 1190 |
| 16 | 7/1.70 | 5.1 | 1.0 | 0.18 | 1.5 | 22.0 | 0.3 | 1.2 | 26.1 | 1.3 | 1550 |
| 25 | 7/2.14 | 6.42 | 1.2 | 0.18 | 1.7 | 26.5 | 0.3 | 1.3 | 30.9 | 1.5 | 2200 |
| 35 | 7/2.52 | 7.56 | 1.2 | 0.18 | 1.8 | 29.5 | 0.3 | 1.4 | 34.0 | 1.7 | 2780 |
| 50 | 19/1.78 | 8.9 | 1.4 | 0.20 | 2.0 | 34.5 | 0.4 | 1.5 | 39.8 | 2.0 | 3750 |
| 70 | 19/2.14 | 10.7 | 1.4 | 0.26 | 2.2 | 39.5 | 0.4 | 1.6 | 45.1 | 2.3 | 5280 |
| 95 | 19/2.52 | 12.6 | 1.6 | 0.26 | 2.4 | 45.9 | 0.4 | 1.8 | 51.8 | 2.6 | 6750 |
| 120 | 37/2.03 | 14.2 | 1.6 | 0.26 | 2.6 | 50.1 | 0.4 | 1.9 | 56.2 | 2.8 | 8150 |
| 150 | 37/2.25 | 15.8 | 1.8 | 0.26 | 2.8 | 55.3 | 0.4 | 2.0 | 61.8 | 3.1 | 1210 |
| 185 | 37/2.52 | 17.6 | 2.0 | 0.26 | 3.0 | 61.2 | 0.4 | 2.2 | 67.9 | 3.4 | 11980 |
STANDARDS
CABLE CONSTRUCTION
| Conductor | D(T,F) | Tinned annealed stranded copper, class 5 according to IEC 60228 |
| Insulation | P | 85°C EPR as per JIS C 3401 |
| Cabling |
Insulated conductors shall be cabled. Flame retardant & non-hygroscopic fillers may be used. |
|
| Sheath | NP | PCP as per JIS C 3410 |
| Core identification |
2C Black, White 3C Black, White, Red 4C Black, White, Red, Green |
|
| Outer sheath color | Black |
Cable Parameter
| No. of Cores | Conductor | Thick. of insulation | Thick. of Sheath | Nom. overall dia. | Tolerance | Cable Weight | ||
| Size | Construction | O.D | ||||||
| mm² | No./mm | mm | mm | mm | mm | mm | kg/km | |
| 2 | 0.75 | 24/0.20 | 1.13 | 1 | 1.4 | 9.7 | 0.4 | 130 |
| 2 | 1 | 32/0.20 | 1.27 | 1 | 1.4 | 9.9 | 0.4 | 135 |
| 2 | 1.5 | 30/0.25 | 1.58 | 1 | 1.5 | 10.8 | 0.4 | 165 |
| 2 | 2.5 | 49/0.25 | 2.02 | 1 | 1.6 | 11.8 | 0.5 | 205 |
| 2 | 4 | 55/0.30 | 2.57 | 1 | 1.7 | 13.1 | 0.5 | 265 |
| 2 | 6 | 82/0.30 | 3.14 | 1 | 1.8 | 14.5 | 0.6 | 340 |
| 3 | 0.75 | 24/0.20 | 1.13 | 1 | 1.4 | 10.2 | 0.4 | 145 |
| 3 | 1 | 32/0.20 | 1.27 | 1 | 1.5 | 10.7 | 0.4 | 160 |
| 3 | 1.5 | 30/0.25 | 1.58 | 1 | 1.5 | 11.4 | 0.5 | 190 |
| 3 | 2.5 | 49/0.25 | 2.02 | 1 | 1.6 | 12.5 | 0.5 | 240 |
| 3 | 4 | 55/0.30 | 2.57 | 1 | 1.8 | 14.1 | 0.6 | 325 |
| 3 | 6 | 82/0.30 | 3.14 | 1 | 1.9 | 15.6 | 0.6 | 420 |
| 4 | 0.75 | 24/0.20 | 1.13 | 1 | 1.5 | 11.3 | 0.5 | 175 |
| 4 | 1 | 32/0.20 | 1.27 | 1 | 1.6 | 11.8 | 0.5 | 200 |
| 4 | 1.5 | 30/0.25 | 1.58 | 1 | 1.6 | 12.2 | 0.5 | 225 |
| 4 | 2.5 | 49/0.25 | 2.02 | 1 | 1.8 | 14.1 | 0.6 | 310 |
| 4 | 4 | 55/0.30 | 2.57 | 1 | 1.9 | 15.6 | 0.6 | 405 |
| 4 | 6 | 82/0.30 | 3.14 | 1 | 2 | 17.2 | 0.7 | 525 |
STANDARDS
CABLE CONSTRUCTION
| Conductor | S | Bunched tinned annealed stranded copper, class 5 according to IEC 60228 |
| Insulation | CP YP | 85°C XLPE / 75°C PVC as per JIS C 3401 |
Cable Parameter
SCP
| Conductor | Thick. of insulation | Nom. overall dia. | Tolerance | Cable Weight | ||
| Size | Construction | O.D | ||||
| mm² | No./mm | mm | mm | mm | mm | kg/km |
| 1.5 | 30/0.25 | 1.58 | 0.9 | 3.7 | 0.4 | 26 |
| 2.5 | 49/0.25 | 2.02 | 1 | 4.3 | 0.4 | 38 |
| 4 | 55/0.30 | 2.57 | 1 | 4.8 | 0.4 | 55 |
| 6 | 82/0.30 | 3.14 | 1 | 5.3 | 0.4 | 75 |
| 10 | 80/0.40 | 4.13 | 1.1 | 6.6 | 0.4 | 125 |
| 16 | 7/18/0.40 | 5.88 | 1.1 | 8.3 | 0.4 | 190 |
| 25 | 7/28/0.40 | 7.32 | 1.2 | 10 | 0.4 | 280 |
| 35 | 7/39/0.40 | 8.67 | 1.4 | 11.8 | 0.5 | 390 |
| 50 | 19/21/0.40 | 10.3 | 1.4 | 13.4 | 0.5 | 550 |
| 70 | 19/19/0.50 | 12.2 | 1.6 | 15.7 | 0.6 | 770 |
| 95 | 19/25/0.50 | 14 | 1.7 | 17.7 | 0.7 | 1000 |
SYP
| Conductor | Thick. of insulation | Nom. overall dia. | Tolerance | Cable Weight | ||
| Size | Construction | O.D | ||||
| mm² | No./mm | mm | mm | mm | mm | kg/km |
| 0.75 | 24/0.20 | 1.13 | 1.2 | 3.8 | 0.4 | 21 |
| 1 | 32/0.20 | 1.27 | 1.2 | 3.9 | 0.4 | 24 |
| 1.5 | 30/0.25 | 1.58 | 1.2 | 4.2 | 0.4 | 30 |
| 2.5 | 49/0.25 | 2.02 | 1.2 | 4.7 | 0.4 | 41 |
| 4 | 55/0.30 | 2.57 | 1.2 | 5.2 | 0.4 | 60 |
| 6 | 82/0.30 | 3.14 | 1.2 | 5.8 | 0.4 | 80 |
| 10 | 80/0.40 | 4.13 | 1.2 | 6.8 | 0.4 | 125 |
| 16 | 7/18/0.40 | 5.88 | 1.3 | 8.7 | 0.4 | 195 |
Certificate Display
Type and routine tests are issued from our own testing centre under the ISO 9001 quality system — test reports and certificates accompany every shipment.
Factory Tour
Why Choose Us
Packing & Shipping
- Wooden, steel or steel-wood drums; drum length to customer requirement
- Drum marking per customer / utility specification
- Both drum ends sealed and protected for sea freight
Ready for Your Next Cable Project?
Send us your specifications, cable schedule or RFQ — our engineering team replies with a technical proposal and price within one working day.
- Emailinfo@qzcablegroup.com
- WhatsApp / WeChat+86 173 3570 4553
- Contact personChloe · Export Department
- Factory addressWest Industrial Park, Zhulin Town, Gongyi City, Henan Province, China
Related products
Related solutions
Power Generation Cable Solutions
QZ Cable supplies power generation cable solutions for thermal, hydro, solar and wind power projects, including LV/MV power cables, control cables, instrumentation cables and overhead conductors.
Power Transmission Cable Solutions
QZ Cable supplies power transmission solutions, including AAC, AAAC, ACSR, ACSS, TACSR, TAAAC, OPGW and ADSS for utility, grid expansion and EPC projects worldwide.
Power Distribution Cable Solutions
Qingzhou Cable provides low- and medium-voltage cable solutions for electrical distribution networks, supporting power delivery from substations to commercial, industrial and residential users.
Power Substation Cable Solutions
Solar & Renewable Energy Cable Solutions