One-stop Solution for Wire & Cable · Since 1969
Covered Line Wire Weatherproof
LV & MV Aerial Cables

Covered Line Wire Weatherproof

Covered line Wire is used primarily for 600v overhead secondary distribution lines. It is not an electrically insulated conductor and is treated as bare conductor when installed.

  • The conductors are 1350-H19 Aluminum Wire, 6201-T81 Aluminum Alloy or ACSR conductors, concentrically stranded and covered for…
  • Basic design to

Product Description

Application

Covered line Wire is used primarily for 600v overhead secondary distribution lines. It is not an electrically insulated conductor and is treated as bare conductor when installed.

Standard

Basic design to

ASTM B-230 – Aluminum Wire 1350-H19 for Electrical Purposes

ASTM B-231 – Concentric-Lay-Stranded Aluminum Conductors

ASTM B-232 – Concentric-Lay-Stranded Aluminum Conductors, Coated-Steel Reinforced (ACSR)

ASTM B-399- Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors

ICEA S-61-402-: Thermoplastic-insulated Wire And Cable For The Transmission And Distribution Of Electrical Energy

ICEA S-66-524-XLPE Insulated Wire and Cable For the Transmission and Distribution of Electrical Energy

Construction

The conductors are 1350-H19 Aluminum Wire, 6201-T81 Aluminum Alloy or ACSR conductors, concentrically stranded and covered for weather proofing with polyethylene, high density polyethylene(HDPE) or cross-linked polyethylene(XLPE).

Construction Parameters

Technical Data

ASTM

3-Layer 15kV ACSR Tree Wire
Size (AWG or kcmil) Stranding Conductor Diameter (mils) Covering Thickness (mils) Cable O.D. (mils)
      Conductor Shield Inner Layer
4 6/1 250 15 75
2 6/1 316 15 75
1/0 6/1 398 15 75
2/0 6/1 447 15 75
3/0 6/1 502 15 75
4/0 6/1 563 15 75
266.8 18/1 609 15 75
266.8 26/7 642 15 75
336.4 18/1 684 15 75
336.4 26/7 720 15 75
336.4 30/7 741 15 75
397.5 18/1 743 15 75
397.5 24/7 772 15 75
397.5 26/7 783 15 75
477 24/7 846 15 75
477 26/7 858 15 75
477 30/7 883 15 75
556.5 18/1 879 20 75
556.5 24/7 914 20 75
556.5 26/7 927 20 75
636 18/1 940 20 75
636 26/7 990 20 75
3-Layer 15kV AAAC Tree  Wire
48.69 4 7 250 15
77.47 2 7 316 15
123.3 1/0 7 398 15
155.4 2/0 7 447 15
195.7 3/0 7 502 15
246.9 4/0 7 563 15
312.8 266.8 19 642 15
394.5 336.4 19 720 15
465.4 397.5 19 783 15
559.5 477 19 858 15
652.4 556.5 19 927 20
740.8 636 37 990 20
3-Layer 15kV AAC Tree Wire
1/0 7 336 15 75
2/0 7 376 15 75
3/0 7 423 15 75
4/0 7 475 15 75
266.8 19 537 15 75
336.4 19 603 15 75
397.5 19 659 15 75
477 19 722 15 75
556.5 37 780 20 75
636 37 835 20 80
795 37 932 20 80
3-Layer 25kV ACSR Tree Wire
1/0 6/1 398 15 125
2/0 6/1 447 15 125
3/0 6/1 502 15 125
4/0 6/1 563 15 125
266.8 18/1 609 15 125
266.8 26/7 642 15 125
336.4 18/1 684 15 125
336.4 26/7 720 15 125
336.4 30/7 741 15 125
397.5 18/1 743 15 125
397.5 24/7 772 15 125
397.5 26/7 783 15 125
477 24/7 846 20 125
477 26/7 858 20 125
477 30/7 883 20 125
556.5 18/1 879 20 125
556.5 24/7 914 20 125
556.5 26/7 927 20 125
3-Layer 25kV AAAC Tree Wire
48.69 4 7 250 15
77.47 2 7 316 15
123.3 1/0 7 398 15
155.4 2/0 7 447 15
195.7 3/0 7 502 15
246.9 4/0 7 563 15
312.8 266.8 19 642 15
394.5 336.4 19 720 15
465.4 397.5 19 783 15
559.5 477 19 858 20
652.4 556.5 19 927 20
740.8 636 37 990 20
927.2 795 37 1108 20
3-Layer 25kV AAC Tree  Wire
1/0 7 336 15 125
2/0 7 376 15 125
3/0 7 423 15 125
4/0 7 475 15 125
266.8 19 537 15 125
336.4 19 603 15 125
397.5 19 659 15 125
477 19 722 20 125
556.5 37 780 20 125
636 37 835 20 125
795 37 932 20 125
3-Layer 35kV ACSR Tree Wire
1/0 6/1 398 15 175
2/0 6/1 447 15 175
4/0 6/1 563 15 175
266.8 18/1 609 15 175
266.8 26/7 642 15 175
336.4 18/1 684 15 175
336.4 26/7 720 15 175
336.4 30/7 741 15 175
397.5 18/1 743 15 175
397.5 24/7 772 15 175
397.5 26/7 783 15 175
477 24/7 846 20 175
477 26/7 858 20 175
477 30/7 883 20 175
556.5 18/1 879 20 175
556.5 24/7 914 20 175
556.5 26/7 927 20 175
636 18/1 940 20 175
636 26/7 990 20 175
795 26/7 1107 20 175
795 45/7 1063 20 175
3-Layer 35kV AAAC Tree  Wire
48.69 4 7 250 15
77.47 2 7 316 15
123.3 1/0 7 398 15
155.4 2/0 7 447 15
195.7 3/0 7 502 15
246.9 4/0 7 563 15
312.8 266.8 19 642 15
394.5 336.4 19 720 15
465.4 397.5 19 783 15
559.5 477 19 858 20
652.4 556.5 19 927 20
3-Layer 35kV AAC Tree  Wire
1/0 7 336 15 175
2/0 7 376 15 175
3/0 7 423 15 175
4/0 7 475 15 175
266.8 19 537 15 175
336.4 19 603 15 175
397.5 19 659 15 175
477 19 722 20 175
556.5 37 780 20 175
636 37 835 20 175
795 37 932 20 175

ICEA

Nominal Size Min.No.
of Wires
Covering Thickness Cable Diameter Min. Breaking Load Weight
Conductor Shield Inner Layer Outer Layer
mm2 No. mm mm mm mm N kg/km
3-Layer 15kV AAC/XLPE/XLPE
25 6 0.60 1.91 1.91 15.2 3762 218
35 6 0.60 1.91 1.91 16.2 5177 258
50 6 0.60 1.91 1.91 17.3 7011 307
70 12 0.60 1.91 1.91 19.0 10354 387
95 15 0.60 1.91 1.91 20.8 13727 482
120 15 0.60 1.91 1.91 22.0 17339 564
150 15 0.60 1.91 1.91 23.7 21033 660
185 30 0.60 1.91 1.91 25.3 26732 780
240 30 0.60 1.91 1.91 27.6 34679 968

Certificate Display

ISO 9001 Quality Management System
ISO 9001 Certificate (2025–2028)
ISO 9001 Certificate (NOA)
CE — Verification of Conformity
RoHS Compliance Attestation (EU)
Low Voltage Directive Attestation (EU)

Type and routine tests are issued from our own testing centre under the ISO 9001 quality system — test reports and certificates accompany every shipment.

Factory Tour

Why Choose Us

50+ years of experience Trusted manufacturing expertise since 1969
International standards IEC, ASTM, BS, CSA and other global standards
Strict quality control Comprehensive testing throughout production
Large production capacity Reliable supply for utility and EPC projects
Fast global delivery Efficient manufacturing and worldwide shipping
Technical support Expert assistance from inquiry to project completion

Packing & Shipping

  • Wooden, steel or steel-wood drums; drum length to customer requirement
  • Drum marking per customer / utility specification
  • Both drum ends sealed and protected for sea freight
Get in touch

Ready for Your Next Cable Project?

Send us your specifications, cable schedule or RFQ — our engineering team replies with a technical proposal and price within one working day.

  • Emailinfo@qzcablegroup.com
  • WhatsApp / WeChat+86 173 3570 4553
  • Contact personChloe · Export Department
  • Factory addressWest Industrial Park, Zhulin Town, Gongyi City, Henan Province, China

    The more specific the standard and size, the faster we can quote.
    Inquiry WhatsApp Email