Covered Aerial Medium Voltage Cable – Spacer Cable & Tree Wire
Tree Wire Cable, Spacer Cable, Medium Voltage Overhead Cable, Messenger Supported Spacer Cable, Covered Overhead Conductor, Track Resistant XLPE Cable, XLPE Covered Conductor, ICEA S-121-733, AAC Tree Wire, AAAC Spacer Cable, ACSR Tree Wire
- Tree Wire & Messenger-Supported Spacer Cable
- AAC | AAAC | ACSR Conductor Options
- Track-Resistant XLPE Covering Available
- Designed for Compact Overhead Distribution Networks
- ICEA S-121-733 | Direct Factory Supply | MOQ: 10KM
Product Overview
QZ Cable supplies Covered Aerial Medium Voltage Conductors, including Tree Wire and Spacer Cable designs, for overhead power distribution networks.
Available with AAC (All Aluminium Conductor), AAAC (All Aluminium Alloy Conductor), and ACSR (Aluminium Conductor Steel Reinforced) conductor configurations, these products combine stranded overhead conductors with high-dielectric-strength insulation and protective outer coverings.
Depending on the design, the covering system may include cross-linked polyethylene (XLPE), high-density polyethylene (HDPE), track-resistant HDPE (TR-HDPE), or track-resistant XLPE (TK-XLPE).
Covered aerial conductors are designed for overhead distribution applications where additional protection against environmental exposure and incidental contact with surrounding vegetation is required. They are available in different insulation and covering configurations for various voltage classes.
Product Types
1. Tree Wire
Tree Wire is a covered overhead conductor designed for power distribution routes where trees and vegetation are close to the right-of-way, such as wooded residential areas.
The protective covering helps reduce power interruptions caused by incidental conductor contact with tree branches and may reduce the need for frequent or extensive vegetation trimming.
Tree Wire is available with AAC, AAAC, and ACSR conductor designs, depending on the required electrical and mechanical characteristics.
2. Spacer Cable
Spacer Cable is an overhead distribution system in which multiple covered phase conductors are installed close together, supported by a messenger and separated by a series of spacers.
This configuration can reduce the space and hardware required for overhead line installation. It is particularly useful in congested areas where conventional overhead line arrangements may require more space.
The complete system requires compatible covered conductors, supporting messenger, spacers, insulators, and associated fittings.
Conductor Options

| Conductor Type | Full Name | Main Construction |
|---|---|---|
| AAC | All Aluminium Conductor | Stranded hard-drawn aluminium wires |
| AAAC | All Aluminium Alloy Conductor | Stranded aluminium alloy wires |
| ACSR | Aluminium Conductor Steel Reinforced | Aluminium wires stranded around a galvanized steel core |
The conductor type can be selected according to the required electrical performance, mechanical strength, line design, and project specifications.
Insulation and Covering Construction
The covering configuration depends on the voltage rating and product design.
One-Layer Covered Conductor
One-layer Tree Wire uses a covered conductor construction. The supplied product data identifies XLPE covering for the listed 5 kV and 15 kV designs.
Multi-Layer Covered Conductor
Multi-layer designs use a conductor shield and additional insulation or protective covering layers.
The supplied technical information identifies the following materials and options:
- Conductor shield: Extruded semi-conductive polymer.
- Insulation: Cross-linked polyethylene (XLPE).
- Outer covering: Weather-, tracking-, and sunlight-resistant high-density polyethylene (HDPE).
- Track-resistant option: Track-resistant HDPE (TR-HDPE) or track-resistant XLPE (TK-XLPE), depending on the specified design.
The exact layer arrangement and material selection should be confirmed for each voltage class and product construction.
Applications
Tree Wire Applications
- Overhead distribution lines in wooded residential areas.
- Distribution routes where tree branches are close to conductors.
- Areas where minimizing vegetation interference is an important design consideration.
- Overhead power networks requiring covered conductors.
Spacer Cable Applications
- Medium-voltage overhead distribution networks.
- Congested urban and residential areas.
- Overhead line installations requiring a compact conductor arrangement.
- Distribution systems using a supporting messenger and spacer assemblies.
Key Features and Benefits
Protection Against Environmental Exposure
Weather-resistant covering materials are specified for outdoor overhead installations.
Reduced Vegetation-Related Interruptions
Tree Wire covering helps reduce interruptions associated with incidental contact between conductors and tree branches.
Compact Overhead Line Configuration
Spacer Cable systems allow multiple covered conductors to be arranged in close proximity using spacers and a supporting messenger.
Multiple Conductor Designs
AAC, AAAC, and ACSR configurations are available in the supplied product range.
Different Covering Options
XLPE, HDPE, TR-HDPE, and TK-XLPE covering options are identified in the supplied technical information. Availability depends on the design and voltage rating.
Applicable Standards and References
The supplied technical information references the following standards:
| Standard | Description |
|---|---|
| ASTM B230 | Aluminum 1350-H19 Wire for Electrical Purposes |
| ASTM B231 | Concentric-Lay-Stranded Aluminum 1350 Conductors |
| ASTM B232 | Concentric-Lay-Stranded Aluminum Conductors, Coated-Steel Reinforced (ACSR) |
| ASTM B398 | Aluminum-Alloy 6201-T81 and 6201-T83 Wire for Electrical Purposes |
| ASTM B399 | Concentric-Lay-Stranded Aluminum-Alloy 6201-T81 Conductors |
| ASTM B400 | Compact Round Concentric-Lay-Stranded Conductors |
| ASTM D2656 | Cross-Linked Polyethylene Insulation for Wire and Cable Rated 2,001 to 35,000 V, as stated in the source |
| ASTM D1248 | Polyethylene Plastics Extrusion Materials for Wire and Cable |
| ICEA S-61-402 | Referenced for physical requirements of the conductor shield |
| ICEA S-66-524 | Referenced for track-resistant XLPE covering |
The source also refers to an American standard covering one-, two-, and three-layer overhead covered conductors for 5 kV, 15 kV, 25 kV, and 35 kV applications. The exact standard designation and editions should be confirmed before being stated as formal compliance claims.
Available Voltage Classes and Designs
Based on the supplied product information, the series includes:
| Covering Design | Voltage Classes in Source | Conductor Types |
|---|---|---|
| One-layer Tree Wire | 5 kV, 15 kV | AAC, ACSR |
| Two-layer Tree Wire | 15 kV | AAC, AAAC, ACSR |
| Three-layer Tree Wire | 15 kV, 25 kV, 35 kV | AAC, AAAC, ACSR |
| Three-layer Tree Wire | 46 kV | AAC, AAAC, ACSR |
The actual availability of each conductor and voltage combination should be confirmed against the approved manufacturing specification.
Technical Specifications
The supplied catalogue contains detailed dimensional and mechanical data for different conductor types and covering designs.
The one-layer product tables include:
- 5 kV AAC Tree Wire
- 5 kV ACSR Tree Wire
- 15 kV AAC Tree Wire
- 15 kV ACSR Tree Wire
| One-Layer 5kv AAC Tree Wire (All-Aluminum Conductors) | |||||
| Size (AWG or kcmil) | Stranding | Cover Thickness (mils) | Cable O.D.+ (mils) | Rated Strenght (lbs) | Weight per 1000 ft. (lbs) |
| XLP | |||||
| 4 | 7 | 80 | 385 | 793 | 72 |
| 2 | 7 | 80 | 443 | 1210 | 102 |
| 1 | 19 | 80 | 482 | 1570 | 121 |
| 1/0 | 19 | 80 | 522 | 1940 | 146 |
| 2/0 | 19 | 80 | 565 | 2400 | 176 |
| 3/0 | 19 | 80 | 616 | 2980 | 215 |
| 4/0 | 19 | 80 | 672 | 3620 | 263 |
| 250 | 37 | 80 | 718 | 4420 | 300 |
| 266.8 | 19 | 80 | 734 | 4470 | 322 |
| 300 | 37 | 80 | 771 | 5300 | 353 |
| 336.4 | 37 | 80 | 807 | 5790 | 391 |
| 350 | 37 | 80 | 821 | 6080 | 406 |
| 477 | 37 | 80 | 931 | 7820 | 536 |
| 500 | 37 | 80 | 950 | 8200 | 560 |
| One-Layer 5kv ACSR Tree Wire (Aluminum Conductor Steel Reinforced) | |||||
| 4 | 6/1 | 80 | 410 | 1770 | 94 |
| 2 | 6/1 | 80 | 476 | 2710 | 137 |
| 1 | 6/1 | 80 | 514 | 3370 | 166 |
| 1/0 | 6/1 | 80 | 558 | 4160 | 202 |
| 2/0 | 6/1 | 80 | 607 | 5040 | 247 |
| 3/0 | 6/1 | 80 | 662 | 6290 | 303 |
| 4/0 | 6/1 | 80 | 723 | 7930 | 374 |
| 266.8 | 18/1 | 80 | 769 | 6540 | 372 |
| 266.8 | 26/7 | 80 | 802 | 10700 | 449 |
| 336.4 | 18/1 | 80 | 844 | 8250 | 458 |
| 336.4 | 26/7 | 80 | 880 | 13400 | 555 |
| 397.5 | 18/1 | 80 | 903 | 9440 | 534 |
| 397.5 | 26/7 | 80 | 943 | 15500 | 647 |
| 477 | 18/1 | 80 | 974 | 11200 | 631 |
| 477 | 26/7 | 80 | 1018 | 185000 | 767 |
| One-Layer 15kv AAC Tree Wire (All-Aluminum Conductors) | |||||
| 4 | 7 | 150 | 525 | 793 | 114 |
| 2 | 7 | 150 | 583 | 1210 | 150 |
| 1 | 19 | 150 | 622 | 1570 | 172 |
| 1/0 | 19 | 150 | 662 | 1940 | — |
| 2/0 | 19 | 150 | 705 | 2400 | 236 |
| 3/0 | 19 | 150 | 756 | 2980 | 279 |
| 4/0 | 19 | 150 | 812 | 3620 | 333 |
| 266.8 | 19 | 150 | 874 | 4470 | 397 |
| 300 | 37 | 150 | 911 | 5300 | 432 |
| 336.4 | 37 | 150 | 947 | 5790 | 473 |
| 350 | 37 | 150 | 961 | 6080 | 489 |
| 477 | 37 | 150 | 1071 | 7820 | 631 |
| 500 | 37 | 150 | 1090 | 8200 | 656 |
| One-Layer 15kv ACSR Tree Wire (Aluminum Conductor Steel Reinforced) | |||||
| 4 | 6/1 | 150 | 550 | 1770 | 139 |
| 2 | 6/1 | 150 | 616 | 2710 | 188 |
| 1 | 6/1 | 150 | 654 | 3370 | 221 |
| 1/0 | 6/1 | 150 | 698 | 4160 | 261 |
| 2/0 | 6/1 | 150 | 747 | 5040 | — |
| 3/0 | 6/1 | 150 | 802 | 6290 | 372 |
| 4/0 | 6/1 | 150 | 863 | 7930 | 449 |
| 266.8 | 18/1 | 150 | 909 | 6540 | 451 |
| 266.8 | 26/7 | 150 | 942 | 10700 | 531 |
| 336.4 | 18/1 | 150 | 984 | 8250 | 545 |
| 336.4 | 26/7 | 150 | 1020 | 13400 | 645 |
| 397.5 | 18/1 | 150 | 1043 | 9440 | 626 |
| 397.5 | 26/7 | 150 | 1083 | 15500 | 743 |
| 477 | 18/1 | 150 | 1114 | 11200 | 730 |
| 477 | 26/7 | 150 | 1158 | 18500 | 870 |
2-Layer 15kV 25kV 35kV Tree Wire
- 15 kV two-layer AAC, AAAC, and ACSR Tree Wire
| 2-Layer 15kV ACSR Tree Wire | ||||
| 4 | 6/1 | 250 | 75 | 75 |
| 2 | 6/1 | 316 | 75 | 75 |
| 1/0 | 6/1 | 398 | 75 | 75 |
| 2/0 | 6/1 | 447 | 75 | 75 |
| 3/0 | 6/1 | 502 | 75 | 75 |
| 4/0 | 6/1 | 563 | 75 | 75 |
| 266.8 | 18/1 | 609 | 75 | 75 |
| 266.8 | 26/7 | 642 | 75 | 75 |
| 336.4 | 18/1 | 684 | 75 | 75 |
| 336.4 | 26/7 | 720 | 75 | 75 |
| 336.4 | 30/7 | 741 | 75 | 75 |
| 397.5 | 18/1 | 743 | 75 | 75 |
| 397.5 | 24/7 | 772 | 75 | 75 |
| 397.5 | 26/7 | 783 | 75 | 75 |
| 477 | 24/7 | 846 | 75 | 75 |
| 477 | 26/7 | 858 | 75 | 75 |
| 477 | 30/7 | 883 | 75 | 75 |
| 556.5 | 18/1 | 879 | 75 | 75 |
| 556.5 | 24/7 | 914 | 75 | 75 |
| 556.5 | 26/7 | 927 | 75 | 75 |
| 636 | 18/1 | 940 | 75 | 75 |
| 636 | 24/7 | 977 | 75 | 75 |
| 636 | 26/7 | 990 | 75 | 75 |
| 795 | 26/7 | 1108 | 80 | 80 |
| 795 | 45/7 | 1063 | 80 | 80 |
| 2-Layer 15kV AAAC Tree Wire | ||||
| 48.69 | 4 | 7 | 250 | 75 |
| 77.47 | 2 | 7 | 316 | 75 |
| 123.3 | 1/0 | 7 | 398 | 75 |
| 155.4 | 2/0 | 7 | 447 | 75 |
| 195.7 | 3/0 | 7 | 502 | 75 |
| 246.9 | 4/0 | 7 | 563 | 75 |
| 312.8 | 266.8 | 19 | 642 | 75 |
| 394.5 | 336.4 | 19 | 720 | 75 |
| 465.4 | 397.5 | 19 | 782 | 75 |
| 559.5 | 477 | 19 | 858 | 75 |
| 652.4 | 556.5 | 19 | 927 | 75 |
| 740.8 | 636 | 37 | 990 | 80 |
| 2-Layer 15kV AAC Tree Wire | ||||
| 1/0 | 7 | 336 | 75 | 75 |
| 2/0 | 7 | 376 | 75 | 75 |
| 3/0 | 7 | 423 | 75 | 75 |
| 4/0 | 7 | 475 | 75 | 75 |
| 266.8 | 19 | 537 | 75 | 75 |
| 336.4 | 19 | 603 | 75 | 75 |
| 397.5 | 19 | 659 | 75 | 75 |
| 477 | 19 | 722 | 75 | 75 |
| 556.5 | 37 | 780 | 75 | 75 |
| 636 | 37 | 835 | 75 | 75 |
3-Layer 15kV 25kV 35kV Tree Wire
- 15 kV three-layer AAC, AAAC, and ACSR Tree Wire
- 25 kV three-layer AAC, AAAC, and ACSR Tree Wire
- 35 kV three-layer AAC, AAAC, and ACSR Tree Wire
- 46 kV three-layer AAC, AAAC, and ACSR Tree Wire
| 3-Layer 15kV ACSR Tree Wire | ||||
| Size (AWG or kcmil) | Stranding | Conductor Diameter (mils) | Covering Thickness (mils) | Cable O.D. (mils) |
| Conductor Shield | Inner Layer | |||
| 4 | 6/1 | 250 | 15 | 75 |
| 2 | 6/1 | 316 | 15 | 75 |
| 1/0 | 6/1 | 398 | 15 | 75 |
| 2/0 | 6/1 | 447 | 15 | 75 |
| 3/0 | 6/1 | 502 | 15 | 75 |
| 4/0 | 6/1 | 563 | 15 | 75 |
| 266.8 | 18/1 | 609 | 15 | 75 |
| 266.8 | 26/7 | 642 | 15 | 75 |
| 336.4 | 18/1 | 684 | 15 | 75 |
| 336.4 | 26/7 | 720 | 15 | 75 |
| 336.4 | 30/7 | 741 | 15 | 75 |
| 397.5 | 18/1 | 743 | 15 | 75 |
| 397.5 | 24/7 | 772 | 15 | 75 |
| 397.5 | 26/7 | 783 | 15 | 75 |
| 477 | 24/7 | 846 | 15 | 75 |
| 477 | 26/7 | 858 | 15 | 75 |
| 477 | 30/7 | 883 | 15 | 75 |
| 556.5 | 18/1 | 879 | 20 | 75 |
| 556.5 | 24/7 | 914 | 20 | 75 |
| 556.5 | 26/7 | 927 | 20 | 75 |
| 636 | 18/1 | 940 | 20 | 75 |
| 636 | 26/7 | 990 | 20 | 75 |
| 3-Layer 15kV AAAC Tree Wire | ||||
| 48.69 | 4 | 7 | 250 | 15 |
| 77.47 | 2 | 7 | 316 | 15 |
| 123.3 | 1/0 | 7 | 398 | 15 |
| 155.4 | 2/0 | 7 | 447 | 15 |
| 195.7 | 3/0 | 7 | 502 | 15 |
| 246.9 | 4/0 | 7 | 563 | 15 |
| 312.8 | 266.8 | 19 | 642 | 15 |
| 394.5 | 336.4 | 19 | 720 | 15 |
| 465.4 | 397.5 | 19 | 783 | 15 |
| 559.5 | 477 | 19 | 858 | 15 |
| 652.4 | 556.5 | 19 | 927 | 20 |
| 740.8 | 636 | 37 | 990 | 20 |
| 3-Layer 15kV AAC Tree Wire | ||||
| 1/0 | 7 | 336 | 15 | 75 |
| 2/0 | 7 | 376 | 15 | 75 |
| 3/0 | 7 | 423 | 15 | 75 |
| 4/0 | 7 | 475 | 15 | 75 |
| 266.8 | 19 | 537 | 15 | 75 |
| 336.4 | 19 | 603 | 15 | 75 |
| 397.5 | 19 | 659 | 15 | 75 |
| 477 | 19 | 722 | 15 | 75 |
| 556.5 | 37 | 780 | 20 | 75 |
| 636 | 37 | 835 | 20 | 80 |
| 795 | 37 | 932 | 20 | 80 |
| 3-Layer 25kV ACSR Tree Wire | ||||
| 1/0 | 6/1 | 398 | 15 | 125 |
| 2/0 | 6/1 | 447 | 15 | 125 |
| 3/0 | 6/1 | 502 | 15 | 125 |
| 4/0 | 6/1 | 563 | 15 | 125 |
| 266.8 | 18/1 | 609 | 15 | 125 |
| 266.8 | 26/7 | 642 | 15 | 125 |
| 336.4 | 18/1 | 684 | 15 | 125 |
| 336.4 | 26/7 | 720 | 15 | 125 |
| 336.4 | 30/7 | 741 | 15 | 125 |
| 397.5 | 18/1 | 743 | 15 | 125 |
| 397.5 | 24/7 | 772 | 15 | 125 |
| 397.5 | 26/7 | 783 | 15 | 125 |
| 477 | 24/7 | 846 | 20 | 125 |
| 477 | 26/7 | 858 | 20 | 125 |
| 477 | 30/7 | 883 | 20 | 125 |
| 556.5 | 18/1 | 879 | 20 | 125 |
| 556.5 | 24/7 | 914 | 20 | 125 |
| 556.5 | 26/7 | 927 | 20 | 125 |
| 3-Layer 25kV AAAC Tree Wire | ||||
| 48.69 | 4 | 7 | 250 | 15 |
| 77.47 | 2 | 7 | 316 | 15 |
| 123.3 | 1/0 | 7 | 398 | 15 |
| 155.4 | 2/0 | 7 | 447 | 15 |
| 195.7 | 3/0 | 7 | 502 | 15 |
| 246.9 | 4/0 | 7 | 563 | 15 |
| 312.8 | 266.8 | 19 | 642 | 15 |
| 394.5 | 336.4 | 19 | 720 | 15 |
| 465.4 | 397.5 | 19 | 783 | 15 |
| 559.5 | 477 | 19 | 858 | 20 |
| 652.4 | 556.5 | 19 | 927 | 20 |
| 740.8 | 636 | 37 | 990 | 20 |
| 927.2 | 795 | 37 | 1108 | 20 |
| 3-Layer 25kV AAC Tree Wire | ||||
| 1/0 | 7 | 336 | 15 | 125 |
| 2/0 | 7 | 376 | 15 | 125 |
| 3/0 | 7 | 423 | 15 | 125 |
| 4/0 | 7 | 475 | 15 | 125 |
| 266.8 | 19 | 537 | 15 | 125 |
| 336.4 | 19 | 603 | 15 | 125 |
| 397.5 | 19 | 659 | 15 | 125 |
| 477 | 19 | 722 | 20 | 125 |
| 556.5 | 37 | 780 | 20 | 125 |
| 636 | 37 | 835 | 20 | 125 |
| 795 | 37 | 932 | 20 | 125 |
| 3-Layer 35kV ACSR Tree Wire | ||||
| 1/0 | 6/1 | 398 | 15 | 175 |
| 2/0 | 6/1 | 447 | 15 | 175 |
| 4/0 | 6/1 | 563 | 15 | 175 |
| 266.8 | 18/1 | 609 | 15 | 175 |
| 266.8 | 26/7 | 642 | 15 | 175 |
| 336.4 | 18/1 | 684 | 15 | 175 |
| 336.4 | 26/7 | 720 | 15 | 175 |
| 336.4 | 30/7 | 741 | 15 | 175 |
| 397.5 | 18/1 | 743 | 15 | 175 |
| 397.5 | 24/7 | 772 | 15 | 175 |
| 397.5 | 26/7 | 783 | 15 | 175 |
| 477 | 24/7 | 846 | 20 | 175 |
| 477 | 26/7 | 858 | 20 | 175 |
| 477 | 30/7 | 883 | 20 | 175 |
| 556.5 | 18/1 | 879 | 20 | 175 |
| 556.5 | 24/7 | 914 | 20 | 175 |
| 556.5 | 26/7 | 927 | 20 | 175 |
| 636 | 18/1 | 940 | 20 | 175 |
| 636 | 26/7 | 990 | 20 | 175 |
| 795 | 26/7 | 1107 | 20 | 175 |
| 795 | 45/7 | 1063 | 20 | 175 |
| 3-Layer 35kV AAAC Tree Wire | ||||
| 48.69 | 4 | 7 | 250 | 15 |
| 77.47 | 2 | 7 | 316 | 15 |
| 123.3 | 1/0 | 7 | 398 | 15 |
| 155.4 | 2/0 | 7 | 447 | 15 |
| 195.7 | 3/0 | 7 | 502 | 15 |
| 246.9 | 4/0 | 7 | 563 | 15 |
| 312.8 | 266.8 | 19 | 642 | 15 |
| 394.5 | 336.4 | 19 | 720 | 15 |
| 465.4 | 397.5 | 19 | 783 | 15 |
| 559.5 | 477 | 19 | 858 | 20 |
| 652.4 | 556.5 | 19 | 927 | 20 |
| 3-Layer 35kV AAC Tree Wire | ||||
| 1/0 | 7 | 336 | 15 | 175 |
| 2/0 | 7 | 376 | 15 | 175 |
| 3/0 | 7 | 423 | 15 | 175 |
| 4/0 | 7 | 475 | 15 | 175 |
| 266.8 | 19 | 537 | 15 | 175 |
| 336.4 | 19 | 603 | 15 | 175 |
| 397.5 | 19 | 659 | 15 | 175 |
| 477 | 19 | 722 | 20 | 175 |
| 556.5 | 37 | 780 | 20 | 175 |
| 636 | 37 | 835 | 20 | 175 |
| 795 | 37 | 932 | 20 | 175 |
Detailed conductor sizes, stranding, conductor diameter, covering thickness, overall diameter, rated strength, and weight should be selected from the applicable product-specific technical table.
Manufacturing and Customization
QZ Cable can review project requirements for covered aerial medium-voltage conductors according to the required conductor type, voltage class, covering construction, and applicable technical specification.
For a technical quotation, please provide:
- Product type: Tree Wire or Spacer Cable
- Conductor type: AAC, AAAC, or ACSR
- Rated voltage
- Required conductor size and stranding
- Number of covering layers
- Required covering material
- Applicable standard and project specification
- Required quantity and delivery length
Frequently Asked Questions
1. What is Tree Wire?
Tree Wire is a covered overhead conductor used in distribution routes where trees and vegetation are close to the power line. Its covering helps reduce interruptions caused by incidental contact with tree branches.
2. What is Spacer Cable?
Spacer Cable is a compact overhead distribution arrangement in which covered phase conductors are supported by a messenger and separated by spacers.
3. What conductor types are available?
The supplied product range includes AAC, AAAC, and ACSR conductor designs.
4. What voltage ratings are available?
The source catalogue includes one-layer designs at 5 kV and 15 kV, two-layer designs at 15 kV, three-layer designs at 15 kV, 25 kV, and 35 kV, and a separate 46 kV three-layer range.
5. Which covering materials are used?
The source identifies XLPE, HDPE, track-resistant HDPE (TR-HDPE), and track-resistant XLPE (TK-XLPE). The actual material combination depends on the product design.
6. Is covered conductor equivalent to fully insulated cable?
Not necessarily. Covered overhead conductors are designed for specific overhead line configurations and must be installed according to the applicable system design, clearances, and safety procedures. The covering should not be treated as authorization for direct contact with an energized conductor.
7. Can the conductor be customized?
Conductor type, size, stranding, voltage class, and covering configuration can be reviewed according to project requirements and the confirmed manufacturing range.
Applicable Standards
Certificate Display
Type and routine tests are issued from our own testing centre under the ISO 9001 quality system — test reports and certificates accompany every shipment.
Factory Tour
Why Choose Us
Packing & Shipping
- Wooden, steel or steel-wood drums; drum length to customer requirement
- Drum marking per customer / utility specification
- Both drum ends sealed and protected for sea freight
Ready for Your Next Cable Project?
Send us your specifications, cable schedule or RFQ — our engineering team replies with a technical proposal and price within one working day.
- Emailinfo@qzcablegroup.com
- WhatsApp / WeChat+86 173 3570 4553
- Contact personChloe · Export Department
- Factory addressWest Industrial Park, Zhulin Town, Gongyi City, Henan Province, China
Related products
ACSR-OC, ACSR/AW-OC & ACSR/AW-TR/OC – Medium Voltage Aerial Insulated Conductors
ACSR-OC, ACSR/AW-OC, ACSR/AW-TR/OC, ACSR-OC cable manufacturer, ACSR/AW insulated conductor, 6.6kV aerial insulated conductor, 22.9kV overhead cable, XLPE insulated ACSR, aluminum clad steel reinforced conductor, KS C 3138, ES-6145-0021, medium voltage aerial conductor
A3CS / AAACS Cable 12/20 kV – XLPE Insulated Aluminium Cable
A3CS cable, AAACS cable, A3CS cable manufacturer, AAACS cable manufacturer, 12/20 kV cable, 20 kV aluminium cable, XLPE insulated aluminium cable, medium voltage aluminium cable, SPLN 41-10 cable, Indonesia medium voltage cable
SIP-3 / SIPn-3 AAsXS / AAsXSn Medium Voltage Self-Supporting Aerial Cable
SIP-3 cable, SIPn-3 cable, AAsXS wire, AAsXSn wire, 20kV aerial cable, 35kV overhead cable, medium voltage insulated wire, aluminium alloy overhead conductor, XLPE insulated aerial wire, flame-retardant overhead cable
Polyethylene Covered Overhead Line Wire – POLY AL, POLY AAC & POLY ACSR
polyethylene covered conductor, polyethylene covered wire, POLY AL conductor, POLY AAC conductor, POLY ACSR conductor, covered overhead line wire, PE covered aluminium conductor, weather resistant overhead conductor, covered ACSR wire
NF2X / NFA2X Aerial Bundled Cable – Copper & Aluminium Conductors
NF2X cable, NFA2X cable, NF2X aerial cable, NFA2X aerial bundled cable, copper aerial bundled cable, aluminium ABC cable, XLPE overhead cable, low voltage aerial cable, HD 626 cable, VDE 0276-626
600V Covered Overhead Line Wire – AAC, AAAC & ACSR
600V covered conductor, covered overhead line wire, covered line wire manufacturer, AAC covered conductor, AAAC covered conductor, ACSR covered conductor, aluminium covered conductor, LDPE covered conductor, HDPE covered conductor, XLPE covered conductor, overhead secondary distribution wire
ANSI — Service Drop Cable
This duplexed cable is suited for supply 120 volts aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for crosslinked polyethylene (XLP)…
0.61k V LV ABC Cable Aerial Bundle Conductor
The aerial bundled cables designed for overhead distribution lines have all conductors made of aluminium 1350 and insulated with XLPE. Can be used for fixed installation as overhead power lines up to 1000 V incl.
Related solutions
Power Generation Cable Solutions
QZ Cable supplies power generation cable solutions for thermal, hydro, solar and wind power projects, including LV/MV power cables, control cables, instrumentation cables and overhead conductors.
Power Transmission Cable Solutions
QZ Cable supplies power transmission solutions, including AAC, AAAC, ACSR, ACSS, TACSR, TAAAC, OPGW and ADSS for utility, grid expansion and EPC projects worldwide.
Power Distribution Cable Solutions
Qingzhou Cable provides low- and medium-voltage cable solutions for electrical distribution networks, supporting power delivery from substations to commercial, industrial and residential users.
Power Substation Cable Solutions
Solar & Renewable Energy Cable Solutions