One-stop Solution for Wire & Cable · Since 1969
A3CS / AAACS Cable 12/20 kV – XLPE Insulated Aluminium Cable
LV & MV Aerial Cables

A3CS / AAACS Cable 12/20 kV – XLPE Insulated Aluminium Cable

A3CS cable, AAACS cable, A3CS cable manufacturer, AAACS cable manufacturer, 12/20 kV cable, 20 kV aluminium cable, XLPE insulated aluminium cable, medium voltage aluminium cable, SPLN 41-10 cable, Indonesia medium voltage cable

  • 12/20 kV XLPE-Insulated Aluminium Alloy Cable
  • Designed for Medium-Voltage Overhead Networks
  • AAAC/S Conductor with XLPE Insulation
  • Manufactured to SPLN 41-10 or Project Specifications
  • Custom Sizes | Direct Factory Supply | Bulk Orders | MOQ: 10KM

Product Overview

QZ Cable supplies A3CS (AAACS) cables designed for medium-voltage power distribution networks. The cable features a stranded aluminium conductor with XLPE insulation and is intended for electrical power transmission at a rated voltage of 12/20 kV.

Compared with bare A3C / AAAC conductors, the A3CS cable incorporates an extruded XLPE insulation layer around the conductor. This construction provides an insulated conductor design for overhead medium-voltage power distribution applications.

Manufacturing can be based on SPLN 41-10 or the agreed manufacturer’s specifications, subject to project requirements.

A3CS / AAACS Cable Construction

The cable consists of the following main components:

  1. Conductor: Stranded aluminium conductor.
  2. Insulation: Extruded cross-linked polyethylene (XLPE) insulation.

The supplied product description identifies a single-core construction. No additional outer sheath or metallic screen is specified in the source information.

Key Features

  • Aluminium conductor: Lightweight conductor material for medium-voltage power distribution.
  • XLPE insulation: Extruded cross-linked polyethylene insulation.
  • Single-core design: Suitable for the specified single-core cable configuration.
  • Multiple conductor sizes: Available in nominal sizes from 35 mm² to 1000 mm².
  • Manufacturing standard: SPLN 41-10 or manufacturer’s specifications, subject to confirmation.
  • Project-based supply: Other specifications and configurations can be discussed upon request.

Applications

A3CS / AAACS 12/20 kV cable is intended for medium-voltage electrical power distribution. It can be used as an insulated aluminium conductor for transferring electrical energy between points in a power network.

The exact installation method and application should be confirmed against the project design, applicable Indonesian requirements, and the cable’s approved technical specification.

Applicable Standards

  • SPLN 41-10 – Referenced for A3CS / AAACS cable projects.
  • IEC 60228 – Conductor requirements, where specified and applicable.
  • IEC 60502-2 – Medium-voltage cable requirements; applicability to this particular overhead cable design must be confirmed against the project specification.

The final standard, test requirements and construction details should be confirmed against the customer’s approved technical documents.

Technical Specifications

ParameterDescription
Product nameA3CS / AAACS Cable
Rated voltage12/20 kV
Conductor materialAluminium
Conductor constructionStranded, single core
InsulationXLPE
Applicable standardSPLN 41-10 or manufacturer’s specification
Nominal conductor size35–1000 mm²
Standard delivery length1,000 m or 500 m, depending on conductor size
Other specificationsAvailable upon request

A3CS / AAACS Cable Technical Data

The following values are transcribed from the supplied product data. Items requiring confirmation are identified in the notes below.

PHYSICAL PROPERTIESELECTRICAL PROPERTIES
Cross Sectional AreaNumber and Diameter WireInsulation ThicknessApprox. Overall DiameterApprox. Cable WeightCalculated Breaking ForceDC. Resistance at 20°CCurrent Carrying CapacityStandard Length
Nominal Size
mm²pcs/mmmmmmkg/kmkgohm/kmAm
357/2.503.0014.001999800.9581671000
5019/1.753.0015.0024013000.7242001000
7019/2.253.0018.0034921500.4382751000
9519/2.503.0019.0041226600.3553151000
1007/4.253.0019.0044128300.3323251000
12019/2.753.0020.0048032200.2933561000
15019/3.253.0023.0063244900.2104231000
15037/2.253.0022.0059341900.2254231000
18537/2.503.0024.0070851700.1834841000
24061/2.253.0027.0090569100.1395961000
30061/2.503.0029.00108885300.1116701000
40061/3.003.0034.001506122900.0778101000
50061/3.253.0036.001740144200.0669301000
63091/3.003.0040.002160183300.05210851000
80091/3.253.0042.002503215150.04412551000
100091/3.753.0048.003265286400.03314501000

Values marked with an asterisk require confirmation against the original technical datasheet.

Manufacturing and Customization

QZ Cable can discuss A3CS / AAACS cable requirements based on the requested conductor size, construction, applicable standard, and project specifications.

Available nominal conductor sizes in the supplied data range from 35 mm² to 1000 mm². Other specifications may be considered upon request.

For an accurate quotation and technical confirmation, please provide:

  • Required conductor size and quantity
  • Applicable standard and project specification
  • Required delivery length
  • Installation and operating conditions
  • Any additional technical or inspection requirements

Frequently Asked Questions

1. What is A3CS / AAACS cable?

A3CS / AAACS is an aluminium conductor cable with XLPE insulation, designed for medium-voltage power distribution. The supplied product specification identifies a single-core construction and a rated voltage of 12/20 kV.

2. What is the difference between A3CS and A3C / AAAC?

The A3CS cable described here has an extruded XLPE insulation layer around its aluminium conductor. A3C / AAAC refers to a bare aluminium-alloy overhead conductor without this insulation layer. The exact conductor alloy and construction should be confirmed from the applicable product specification.

3. What voltage rating is available?

The supplied product data identifies a rated voltage of 12/20 kV. The precise voltage designation and applicable system requirements should be confirmed in the project specification.

4. Which standards apply to A3CS cable?

The supplied specification refers to SPLN 41-10 or manufacturer’s specifications. The required standard and its applicable edition should be agreed before production.

5. What conductor sizes are available?

The supplied size range covers nominal conductor sizes from 35 mm² to 1000 mm². Other specifications may be discussed upon request.

6. Can the cable be manufactured to project requirements?

Project-specific requirements can be reviewed based on the required conductor construction, insulation, dimensions, applicable standards, and delivery conditions.

Certificate Display

ISO 9001 Quality Management System
ISO 9001 Certificate (2025–2028)
ISO 9001 Certificate (NOA)
CE — Verification of Conformity
RoHS Compliance Attestation (EU)
Low Voltage Directive Attestation (EU)

Type and routine tests are issued from our own testing centre under the ISO 9001 quality system — test reports and certificates accompany every shipment.

Factory Tour

Why Choose Us

50+ years of experience Trusted manufacturing expertise since 1969
International standards IEC, ASTM, BS, CSA and other global standards
Strict quality control Comprehensive testing throughout production
Large production capacity Reliable supply for utility and EPC projects
Fast global delivery Efficient manufacturing and worldwide shipping
Technical support Expert assistance from inquiry to project completion

Packing & Shipping

  • Wooden, steel or steel-wood drums; drum length to customer requirement
  • Drum marking per customer / utility specification
  • Both drum ends sealed and protected for sea freight
Get in touch

Ready for Your Next Cable Project?

Send us your specifications, cable schedule or RFQ — our engineering team replies with a technical proposal and price within one working day.

  • Emailinfo@qzcablegroup.com
  • WhatsApp / WeChat+86 173 3570 4553
  • Contact personChloe · Export Department
  • Factory addressWest Industrial Park, Zhulin Town, Gongyi City, Henan Province, China

    The more specific the standard and size, the faster we can quote.

    Related products

    NF2X / NFA2X Aerial Bundled Cable – Copper & Aluminium Conductors NF2X cable, NFA2X cable, NF2X aerial cable, NFA2X aerial bundled cable, copper aerial bundled cable, aluminium ABC cable, XLPE overhead cable, low voltage aerial cable, HD 626 cable, VDE 0276-626 E-A2Y 0.6/1 kV PE-Insulated Self-Supporting Aerial Cable E-A2Y cable, E-A2Y 0.6/1 kV, PE insulated aerial cable, polyethylene insulated overhead cable, self-supporting aerial cable, aluminium aerial cable, low voltage overhead cable, OVE E 8200-626 600V Covered Overhead Line Wire – AAC, AAAC & ACSR 600V covered conductor, covered overhead line wire, covered line wire manufacturer, AAC covered conductor, AAAC covered conductor, ACSR covered conductor, aluminium covered conductor, LDPE covered conductor, HDPE covered conductor, XLPE covered conductor, overhead secondary distribution wire AER — cable LV & MV Aerial Cables ANSI — Service Drop Cable This duplexed cable is suited for supply 120 volts aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for crosslinked polyethylene (XLP)… Amka Cable Low Voltage Twsit Overhead Cable Amka Cable Low Voltage Twsit Overhead Cable 16mm2 Twin Conductor Wire AAC PVC Parallel Aluminum Cable 16mm2 Twin Conductor Wire AAC PVC Parallel Aluminum Cable 0.61k V LV ABC Cable Aerial Bundle Conductor The aerial bundled cables designed for overhead distribution lines have all conductors made of aluminium 1350 and insulated with XLPE. Can be used for fixed installation as overhead power lines up to 1000 V incl. High Conductivity Aluminium Alloy Conductor (AAAC) – AL5, AL6, AL7, AL57, AL59 & Alloy 1120 high conductivity aluminium alloy conductor, AAAC conductor, AAAC manufacturer, AL5 conductor, AL6 conductor, AL7 conductor, AL57 conductor, AL59 conductor, Alloy 1120 conductor, high conductivity AAAC, aluminium alloy overhead conductor, overhead transmission conductor, BS EN 50182 AAAC AL7 Conductor – All Aluminium Alloy Conductor AAAC conductor, AAAC AL7, AL7 conductor, AL7 aluminium alloy conductor, all aluminium alloy conductor, aluminium alloy overhead conductor, AAAC conductor manufacturer, EN 50182 conductor, overhead transmission conductor, overhead distribution conductor AAAC (AL59) Conductor – High-Strength Aluminium Alloy Conductor AAAC conductor, AAAC AL59, AL59 conductor, aluminum alloy conductor, all aluminium alloy conductor, AAAC conductor manufacturer, SS 424 08 14, SS EN 50182, overhead alloy conductor, stranded aluminum alloy conductor, grease filled AAAC conductor AAC (AL1) – All Aluminium Conductor AAC conductor, AAC conductor manufacturer, all aluminium conductor, AL1 conductor, AAC overhead conductor, bare aluminium conductor, aluminium stranded conductor, SS EN 50182, overhead distribution conductor, aluminium power conductor AAAC — Aluminum Alloy Conductor AAAC conductor, AAAC conductor manufacturer, all aluminum alloy conductor, AAAC cable, ASTM B399 AAAC, aluminum alloy overhead conductor, overhead transmission conductor, overhead distribution conductor, AAAC 6201, bare overhead conductor AAC — All Aluminum Conductor AAC conductor, AAC conductor manufacturer, all aluminium conductor, all aluminum conductor, AAC cable, aluminum stranded conductor, aluminium stranded conductor, Aluminum 1350-H19 conductor, ASTM B230, ASTM B231, AS/NZS 1531, DIN 48201 Part 5, GOST 839-80, BS 215-1, BS EN 50182, IEC 61089, bare overhead conductor, overhead distribution conductor. ACSR — Aluminum Conductor Steel Reinforced ACSR conductor, ACSR conductor manufacturer, ACSR cable, ACSR/AW conductor, ACSR/TW conductor, aluminum conductor steel reinforced, aluminum clad steel reinforced conductor, trapezoidal wire ACSR, overhead transmission conductor, bare overhead conductor, ASTM B232, ASTM B549, ASTM B779, IEC 61089. ACAR — Aluminum Conductor, Aluminum-Alloy Reinforced ACAR conductor, ACAR conductor manufacturer, aluminum alloy reinforced conductor, aluminum conductor alloy reinforced, 1350/6201 conductor, ASTM B524 ACAR, overhead ACAR conductor, bare overhead conductor, overhead transmission conductor, aluminum alloy conductor AACSR — Aluminum Alloy Conductor Steel Reinforced AACSR conductor, AACSR conductor manufacturer, AACSR cable, AACSR/AW conductor, aluminum alloy conductor steel reinforced, aluminum alloy overhead conductor, aluminum clad steel reinforced conductor, 6201 aluminum alloy conductor, IEC 61089 conductor, ASTM B711 conductor, AS 3607 conductor, long span overhead conductor, high strength transmission conductor.
    Inquiry WhatsApp Email