Service Drop Cable – Duplex, Triplex & Quadruplex
Duplex Service Drop Cable, Triplex Service Drop Cable, Quadruplex Service Drop Cable, Aluminum Service Cable, Overhead Service Cable, PE Insulated Service Drop Cable, XLPE Service Drop Cable, AAC Neutral Messenger, AAAC Neutral Messenger, ACSR Neutral Messenger, 600V Service Drop Cable
- 600 V Overhead Service Cable
- 1350-H19 Aluminum Conductors | PE or XLPE Insulation | AAC / AAAC / ACSR Neutral Messenger
- For Overhead Low-Voltage Service Connections
- ASTM & ICEA Standards | Direct Factory Supply | MOQ: 10km
Product Overview
QZ Cable Service Drop Cable is an overhead aluminum cable designed for low-voltage electrical service connections between utility distribution lines or pole-mounted transformers and consumers’ service entrance equipment.
Available in Duplex, Triplex and Quadruplex configurations, the cable is suitable for residential and commercial service connections, temporary power supplies, and outdoor or street lighting installations. It features concentrically stranded, compressed 1350-H19 aluminum phase conductors with polyethylene (PE) or cross-linked polyethylene (XLPE/XLP) insulation.
The neutral messenger can be manufactured using AAC, AAAC (6201-T81 aluminum alloy), or ACSR, depending on the required configuration and mechanical strength.
Applications
Duplex Service Drop Cable
- Supplies 120 V aerial service to residential and other low-voltage installations.
- Used for temporary electrical service at construction sites.
- Suitable for outdoor and street lighting installations.
- Designed for service at 600 V or lower.
Triplex Service Drop Cable
- Supplies power from utility distribution lines to the consumer’s weatherhead.
- Used for overhead service connections at 600 V or less, phase-to-phase.
Quadruplex Service Drop Cable
- Used to supply three-phase power, typically from a pole-mounted transformer to the consumer’s service head.
- Suitable for overhead service connections at 600 V or less, phase-to-phase.
Applicable Standards
The service drop cable meets or exceeds the following ASTM and industry specifications:
- ASTM B-230 – Aluminum 1350-H19 Wire for Electrical Purposes
- ASTM B-231 – Aluminum Conductors, Concentric-Lay-Stranded
- ASTM B-232 – Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR)
- ASTM B-399 – Concentric-Lay-Stranded, 6201-T81 Aluminum Alloy Conductors
- ASTM B-901 – Compressed Round Stranded Aluminum Conductors Using Single Input Wire
- ANSI/ICEA S-76-474
Cable Construction
Phase Conductor
- Material: 1350-H19 aluminum
- Construction: Concentric-lay-stranded, compressed aluminum
- Available conductor sizes and strand configurations vary by cable type.
Insulation
- Material: Polyethylene (PE) or cross-linked polyethylene (XLPE/XLP)
- Insulation thickness: Available in different nominal thicknesses according to conductor size and cable configuration.
Neutral Messenger
The neutral messenger is concentrically stranded and can be supplied in the following constructions:
- AAC – All Aluminium Conductor
- AAAC – All Aluminium Alloy Conductor, 6201-T81
- ACSR – Aluminium Conductor Steel Reinforced
The messenger construction and rated strength depend on the selected cable configuration.
Product Configurations
| Cable Type | Typical Configuration | Application |
|---|---|---|
| Duplex | Two conductors, including one insulated phase conductor and one neutral messenger | Single-phase overhead service |
| Triplex | Three-conductor service cable assembly | Single-phase overhead service |
| Quadruplex | Four-conductor service cable assembly | Three-phase overhead service |
Electrical and Temperature Ratings
| Parameter | PE Insulation | XLPE/XLP Insulation |
|---|---|---|
| Service voltage | 600 V or lower | 600 V or lower |
| Maximum conductor temperature | 75°C | 90°C |
The voltage and temperature ratings above follow the supplied source information. Confirm the applicable cable configuration and project requirements when ordering.
Available Technical Data
The source specification tables cover the following configurations:
- Duplex – AAC phase conductor with AAC neutral messenger
- Duplex – AAC phase conductor with ACSR neutral messenger
- Duplex – AAC phase conductor with AAAC neutral messenger
- Triplex – AAC phase conductor with AAC neutral messenger
- Triplex – AAC phase conductor with ACSR neutral messenger
- Triplex – AAC phase conductor with AAAC neutral messenger
- Quadruplex – AAC phase conductor with AAC neutral messenger
- Quadruplex – AAC phase conductor with ACSR neutral messenger
- Quadruplex – AAC phase conductor with AAAC neutral messenger
Technical data note: The individual Code Word tables should be displayed with their original configuration headings and column labels. The values are approximate and subject to normal manufacturing tolerances. Compatibility with glands, connectors and accessories should be checked against the actual product dimensions. Other sizes are available upon request.
Manufacturing & Customization
QZ Cable can manufacture service drop cables according to project specifications, applicable standards and required conductor configurations.
Customers can submit their required cable type, conductor size, insulation material, neutral messenger construction and applicable technical requirements for evaluation and quotation.
Construction Parameters
Duplex Service Drop Cable (600V)
| Code Name | Phase conductor | Bare Neutral Message | Nominal Weight (kg/km) | Allowable Ampacity | |||||
| Size & No.of wires | Insulation Thick(mm) | Nominal Diameter (mm) | Size & No.of wires | Rated Strength (kg) | XLPE | Aluminum | (A) | ||
| Bare | OD | ||||||||
| AAC Bare Neutral Wire Supported | |||||||||
| Pekingese | 6-Solid | 1.14 | 4.1 | 6.4 | 6-7 | 255 | 20.8 | 72.9 | 78 |
| Collie | 6-7 | 1.14 | 4.6 | 6.9 | 6-7 | 255 | 23.8 | 72.9 | 78 |
| Cocker | 6-7 | 1.52 | 4.6 | 7.7 | 6-7 | 255 | 32.7 | 72.9 | 78 |
| Dachshund | 4-Solid | 1.14 | 5.2 | 7.5 | 6-7 | 400 | 26.8 | 114.6 | 103 |
| Spaniel | 4-7 | 1.14 | 5.9 | 8.2 | 6-7 | 400 | 29.8 | 116.1 | 103 |
| Cairn | 4-7 | 1.52 | 5.9 | 8.9 | 6-7 | 400 | 40.2 | 116.1 | 103 |
| Doberman | 2-7 | 1.14 | 7.4 | 9.7 | 2-7 | 612 | 38.7 | 184.5 | 136 |
| Airedale | 1-19 | 1.52 | 8.4 | 11.5 | 1-7 | - | 56.5 | 233.6 | 158 |
| Basset | 1/0-7 | 1.52 | 9.3 | 12.4 | 1/0-7 | 903 | 64 | 294.7 | 182 |
| Malemure | 1/0-19 | 1.52 | 9.4 | 12.5 | 1/0-7 | 903 | 64 | 294.7 | 182 |
| AAAC Bare Neutral Wire Supported | |||||||||
| Chihuahua | 6-Solid | 1.14 | 4.1 | 6.4 | 6-7 | 499 | 20.8 | 72.9 | 78 |
| Vizsla | 6-7 | 1.14 | 4.6 | 6.9 | 6-7 | 499 | 23.8 | 72.9 | 78 |
| Harrier | 4-Solid | 1.14 | 5.2 | 7.5 | 4-7 | 798 | 26.8 | 116.1 | 103 |
| Whippet | 4-7 | 1.14 | 5.9 | 8.2 | 4-7 | 798 | 29.8 | 116.1 | 103 |
| Schnauzer | 2-7 | 1.14 | 7.4 | 9.7 | 2-7 | 1270 | 38.7 | 184.5 | 136 |
| Afghan | 1/0-7 | 1.52 | 9.3 | 12.4 | 1/0-7 | 2023 | 64 | 296.1 | 182 |
| Heeler | 1/0-19 | 1.52 | 9.4 | 12.5 | 1/0-7 | 2023 | 64 | 296.1 | 182 |
| ACSR Bare Neutral Wire Supported | |||||||||
| Setter | 6-Solid | 1.14 | 4.1 | 6.4 | 6/6/01 | 540 | 20.8 | 72.9 | 78 |
| Shepherd | 6-7 | 1.14 | 4.6 | 6.9 | 6/6/01 | 540 | 23.8 | 72.9 | 78 |
| Retriever | 6-7 | 1.52 | 4.6 | 7.7 | 6/6/01 | 540 | 32.7 | 72.9 | 78 |
| Eskimo | 4-Solid | 1.14 | 5.2 | 7.5 | 4/6/01 | 844 | 26.8 | 114.6 | 103 |
| Terrier | 4-7 | 1.14 | 5.9 | 8.2 | 4/6/01 | 844 | 29.8 | 116.1 | 103 |
| Yorkshirc | 4-7 | 1.52 | 5.9 | 8.9 | 4/6/01 | 844 | 40.2 | 116.1 | 103 |
| Chow | 2-7 | 1.14 | 7.4 | 9.7 | 2/6/01 | 1293 | 38.7 | 184.5 | 136 |
| Labrador | 1-19 | 1.52 | 8.4 | 11.5 | 2/6/01 | 1610 | 56.5 | 233.6 | 158 |
| Bloodhound | 1/0-7 | 1.52 | 9.3 | 12.4 | 1/0-6/1 | 1987 | 64 | 294.7 | 182 |
| Bull | 1/0-19 | 1.52 | 9.4 | 12.5 | 1/0-6/1 | 1987 | 64 | 294.7 | 182 |
Triplex Service Drop Cable (600V)
Triplex – AAC Conductor and AAC Neutral Messenger
| Code Word | Phase Conductor Size (AWG or kcmil) | Phase Conductor Strands | Insulation Thickness (mil) | Cable OD (in) | Neutral Messenger Size (AWG or kcmil) | Neutral Messenger Strands | Rated Strength (lb) | Weight – PE (lb/kft) | Weight – XLPE (lb/kft) |
|---|---|---|---|---|---|---|---|---|---|
| Haliotis | 6 | 1 | 45 | 0.26 | 6 | 7 | 563 | 101 | 100 |
| Patella | 6 | 7 | 45 | 0.28 | 6 | 7 | 563 | 108 | 107 |
| Fusus | 4 | 1 | 45 | 0.30 | 4 | 7 | 881 | 149 | 149 |
| Oyster | 4 | 7 | 45 | 0.33 | 4 | 7 | 881 | 159 | 158 |
| Clam | 2 | 7 | 45 | 0.39 | 2 | 7 | 1,350 | 240 | 238 |
| Snail | 1/0 | 7 | 60 | 0.50 | 2 | 7 | 1,350 | 387 | 385 |
| Murex | 1/0 | 7 | 60 | 0.50 | 1/0 | 7 | 1,990 | 387 | 385 |
| Purpura | 1/0 | 19 | 60 | 0.50 | 1/0 | 7 | 1,990 | 382 | 380 |
| Nassa | 2/0 | 7 | 60 | 0.55 | 2/0 | 7 | 2,510 | 477 | 474 |
| Trophon | 2/0 | 19 | 60 | 0.55 | 2/0 | 7 | 2,510 | 471 | 469 |
| Melita | 3/0 | 19 | 60 | 0.60 | 3/0 | 19 | 3,040 | 581 | 579 |
| Portunus | 4/0 | 19 | 60 | 0.65 | 4/0 | 19 | 3,830 | 721 | 718 |
| Nannynose | 336.4 | 19 | 80 | 0.83 | 336.4 | 19 | 6,150 | 1,162 | 1,157 |
Notes: The above data are approximate and subject to normal manufacturing tolerances. Where required, compatibility with glands, connectors and accessories should be verified using the actual product dimensions. Other sizes are available upon request.
Triplex (Continued) – AAC Conductor and ACSR Neutral Messenger
| Code Word | Phase Conductor Size (AWG or kcmil) | Phase Conductor Strands | Insulation Thickness (mil) | Cable OD (in) | Neutral Messenger Size (AWG or kcmil) | Neutral Messenger Strands | Rated Strength (lb) | Weight – PE (lb/kft) | Weight – XLPE (lb/kft) |
|---|---|---|---|---|---|---|---|---|---|
| Paludina | 6 | 1 | 45 | 0.26 | 6 | 6/1 | 1,190 | 112 | 112 |
| Voluta | 6 | 7 | 45 | 0.28 | 6 | 6/1 | 1,190 | 119 | 119 |
| Bolma | 6 | 7 | 60 | 0.31 | 6 | 6/1 | 1,190 | 132 | 131 |
| Scallop | 4 | 1 | 45 | 0.30 | 6 | 6/1 | 1,190 | 147 | 146 |
| Strombus | 4 | 7 | 45 | 0.33 | 6 | 6/1 | 1,190 | 156 | 155 |
| Whelk | 4 | 1 | 45 | 0.30 | 4 | 6/1 | 1,860 | 168 | 168 |
| Periwinkle | 4 | 7 | 45 | 0.33 | 4 | 6/1 | 1,860 | 178 | 177 |
| Calma | 4 | 7 | 60 | 0.36 | 4 | 6/1 | 1,860 | 192 | 191 |
| Cockle | 2 | 7 | 45 | 0.39 | 4 | 6/1 | 1,860 | 235 | 234 |
| Conch | 2 | 7 | 45 | 0.39 | 2 | 6/1 | 2,850 | 270 | 269 |
| Gebia | 2 | 7 | 60 | 0.42 | 4 | 6/1 | 1,860 | 252 | 250 |
| Janthina | 1/0 | 7 | 60 | 0.50 | 2 | 6/1 | 2,850 | 380 | 378 |
| Ranella | 1/0 | 19 | 60 | 0.50 | 2 | 6/1 | 2,850 | 375 | 373 |
| Neritina | 1/0 | 7 | 60 | 0.50 | 1/0 | 6/1 | 4,380 | 435 | 433 |
| Cenia | 1/0 | 19 | 60 | 0.50 | 1/0 | 6/1 | 4,380 | 430 | 428 |
| Cavolinia | 2/0 | 7 | 60 | 0.55 | 1 | 6/1 | 3,550 | 468 | 465 |
| Clio | 2/0 | 19 | 60 | 0.55 | 1 | 6/1 | 3,550 | 462 | 460 |
| Runcina | 2/0 | 7 | 60 | 0.55 | 2/0 | 6/1 | 5,300 | 537 | 535 |
| Triton | 2/0 | 19 | 60 | 0.55 | 2/0 | 6/1 | 5,300 | 531 | 529 |
| Aega | 3/0 | 19 | 60 | 0.60 | 1/0 | 6/1 | 4,380 | 570 | 568 |
| Mursia | 3/0 | 19 | 60 | 0.60 | 3/0 | 6/1 | 6,620 | 658 | 655 |
| Cerapus | 4/0 | 19 | 60 | 0.65 | 2/0 | 6/1 | 5,300 | 705 | 702 |
| Zuzara | 4/0 | 19 | 60 | 0.65 | 4/0 | 6/1 | 8,350 | 815 | 813 |
| Dosinia | 266.8 | 19 | 80 | 0.76 | 266.8 | 18/1 | 6,880 | 982 | 977 |
| Cowry | 336.4 | 19 | 80 | 0.83 | 4/0 | 6/1 | 8,350 | 1,137 | 1,132 |
| Limpet | 336.4 | 19 | 80 | 0.83 | 336.4 | 18/1 | 8,680 | 1,213 | 1,208 |
Triplex – AAC Conductor and AAAC Neutral Messenger
| Code Word | Phase Conductor Size (AWG or kcmil) | Phase Conductor Strands | Insulation Thickness (mil) | Cable OD (in) | Neutral Messenger Size (AWG or kcmil) | Neutral Messenger Strands | Rated Strength (lb) | Weight – PE (lb/kft) | Weight – XLPE (lb/kft) |
|---|---|---|---|---|---|---|---|---|---|
| Minex | 6 | 1 | 45 | 0.26 | 6 | 7 | 1,110 | 105 | 104 |
| Hippa | 6 | 7 | 45 | 0.28 | 6 | 7 | 1,110 | 112 | 111 |
| Artemia | 4 | 1 | 45 | 0.30 | 6 | 7 | 1,110 | 139 | 138 |
| Crab | 4 | 1 | 45 | 0.33 | 6 | 7 | 1,110 | 143 | 142 |
| Prawn | 4 | 1 | 45 | 0.30 | 4 | 7 | 1,760 | 156 | 156 |
| Barnacles | 4 | 7 | 45 | 0.33 | 4 | 7 | 1,760 | 166 | 165 |
| Solaster | 2 | 7 | 45 | 0.39 | 4 | 7 | 1,760 | 223 | 222 |
| Shrimp | 2 | 7 | 45 | 0.39 | 2 | 7 | 2,800 | 251 | 250 |
| Lobster | 2 | 7 | 60 | 0.42 | 2 | 7 | 2,800 | 268 | 266 |
| Sandcrab | 1/0 | 7 | 60 | 0.50 | 2 | 7 | 2,800 | 361 | 359 |
| Echinus | 1/0 | 19 | 60 | 0.50 | 2 | 7 | 2,800 | 356 | 354 |
| Gammarus | 1/0 | 7 | 60 | 0.50 | 1/0 | 7 | 4,270 | 405 | 403 |
| Leda | 1/0 | 19 | 60 | 0.50 | 1/0 | 7 | 4,270 | 400 | 398 |
| Dungeness | 2/0 | 7 | 60 | 0.55 | 2/0 | 7 | 5,390 | 499 | 497 |
| Cyclops | 2/0 | 19 | 60 | 0.55 | 2/0 | 7 | 5,390 | 493 | 497 |
| Fulgur | 3/0 | 19 | 60 | 0.60 | 1/0 | 7 | 4,270 | 540 | 537 |
| Flustra | 3/0 | 19 | 60 | 0.60 | 3/0 | 7 | 6,790 | 609 | 607 |
| Arca | 4/0 | 19 | 60 | 0.65 | 2/0 | 7 | 5,390 | 667 | 665 |
| Lepas | 4/0 | 19 | 60 | 0.65 | 4/0 | 7 | 8,560 | 755 | 752 |
Notes: The above data are approximate and subject to normal manufacturing tolerances. Where required, compatibility with glands, connectors and accessories should be verified using the actual product dimensions. Other sizes are available upon request.
Quadruplex Service Drop Cable (600V)
| Quadruplex service drop | ||||||||||
| Code Name | Phase conductor | Bare Neutral Message | Nominal Weight (kg/km) | Ampacity | ||||||
| Size & No.of wires | Insulation Thick (mm) | Nominal Dia. (mm) | Size & No.of wires | Rated Strength (kg) | XLPE | Al | Total | Amps | ||
| Bare | OD | |||||||||
| AAAC | ||||||||||
| Bay | 6-Solid | 1.143 | 4.115 | 6.401 | 6-7 | 503.485 | 63 | 155 | 217 | 78 |
| French-conch | 6-7 | 1.143 | 4.674 | 6.960 | 6-7 | 503.485 | 71 | 155 | 226 | 78 |
| Cerman-conch | 4-Solid | 1.143 | 5.182 | 7.468 | 4-7 | 798.318 | 79 | 247 | 324 | 103 |
| Arabian | 4-7 | 1.143 | 5.893 | 8.179 | 4-7 | 784.711 | 89 | 247 | 336 | 103 |
| Belgain | 2-7 | 1.143 | 7.417 | 9.703 | 2-7 | 1270.052 | 115 | 391 | 506 | 136 |
| Saddle | 1-19 | 1.524 | 8.433 | 11.481 | 2-7 | 1270.052 | 171 | 466 | 637 | 158 |
| Plow | 1/0-7 | 1.524 | 9.347 | 12.395 | 1/0-7 | 2023.011 | 192 | 624 | 814 | 182 |
| Sherland | 1/0-19 | 1.524 | 9.474 | 12.522 | 1/0-7 | 2023.011 | 193 | 624 | 817 | 182 |
| Dapple-grey | 2/0-7 | 1.524 | 10.516 | 13.564 | 2/0-7 | 2444.850 | 217 | 786 | 1005 | 210 |
| Thoroughbred | 2/0-19 | 1.524 | 10.643 | 13.691 | 2/0-7 | 2444.850 | 220 | 786 | 1007 | 210 |
| Dobbin | 3/0-7 | 1.524 | 11.786 | 14.834 | 3/0-7 | 3079.876 | 249 | 991 | 1238 | 242 |
| Trotter | 3/0-19 | 1.524 | 11.938 | 14.986 | 3/0-7 | 3079.876 | 251 | 991 | 1243 | 242 |
| Pony | 4/0-7 | 1.524 | 13.259 | 16.307 | 4/0-7 | 3882.730 | 286 | 1250 | 1534 | 279 |
| Walking | 4/0-19 | 1.524 | 13.411 | 16.459 | 4/0-7 | 3882.730 | 289 | 1250 | 1539 | 279 |
| ACSR | ||||||||||
| Morochuca | 6-Solid | 1.143 | 4.115 | 6.401 | 6-6/1 | 539.722 | 63 | 149 | 229 | 78 |
| Chola | 6-7 | 1.143 | 4.674 | 6.96 | 6-6/1 | 539.722 | 71 | 149 | 237 | 78 |
| Morgan | 4-Solid | 1.143 | 5.182 | 7.468 | 4-6/1 | 843.677 | 79 | 238 | 344 | 103 |
| Hackney | 4-7 | 1.143 | 5.893 | 8.179 | 4-6/1 | 843.677 | 90 | 238 | 356 | 103 |
| Palomino | 2-7 | 1.143 | 7.417 | 9.703 | 2-6/1 | 1292.732 | 115 | 377 | 557 | 136 |
| Albino | 1-19 | 1.524 | 8.433 | 11.481 | 1-6/1 | 1610.245 | 171 | 473 | 699 | 158 |
| Standardbred | 1/0-7 | 1.524 | 9.347 | 12.395 | 1/0-6/1 | 1986.724 | 192 | 598 | 859 | 182 |
| Costena | 1/0-19 | 1.524 | 9.474 | 12.522 | 1/0-6/1 | 1986.724 | 193 | 598 | 862 | 182 |
| Chicoteagues | 2/0-7 | 1.524 | 10.516 | 13.564 | 2/0-6/1 | 2404.027 | 217 | 753 | 1060 | 210 |
| Grullo | 2/0-19 | 1.524 | 10.643 | 13.691 | 2/0-6/1 | 2404.027 | 220 | 753 | 1063 | 210 |
| mare | 3/0-7 | 1.524 | 11.786 | 14.834 | 3/0-6/1 | 3002.766 | 249 | 951 | 1308 | 242 |
| Suffolk | 3/0-19 | 1.524 | 11.938 | 14.986 | 3/0-6/1 | 3002.766 | 251 | 951 | 1313 | 242 |
| Stallion | 4/0-7 | 1.524 | 13.259 | 16.307 | 4/0-6/1 | 3787.477 | 286 | 1198 | 1622 | 279 |
| Appaloosa | 4/0-19 | 1.524 | 13.411 | 16.459 | 4/0-6/1 | 3787.477 | 289 | 1198 | 1627 | 279 |
| AAC | ||||||||||
| Quarter | 6-Solid | 1.143 | 4.115 | 6.401 | 6-7 | 255.371 | 63 | 149 | 211 | 78 |
| Clydesdale | 4-Solid | 1.143 | 5.182 | 7.468 | 4-7 | 399.613 | 79 | 237 | 315 | 103 |
| Pinto | 4-7 | 1.143 | 5.893 | 8.179 | 4-7 | 399.613 | 89 | 237 | 326 | 136 |
| Mustang | 2-7 | 1.143 | 7.417 | 9.703 | 2-7 | 612.347 | 115 | 377 | 491 | 158 |
| Shire | 1-19 | 1.524 | 8.433 | 11.481 | 1-19 | 743.888 | 171 | 475 | 646 | 158 |
| Libyan | 1/0-7 | 1.524 | 9.347 | 12.395 | 1/0-7 | 902.644 | 192 | 598 | 790 | 182 |
| Criollo | 1/0-19 | 1.524 | 9.474 | 12.522 | 1/0-19 | 902.644 | 193 | 598 | 793 | 182 |
| Orloff | 2/0-7 | 1.524 | 10.516 | 13.564 | 2/0-7 | 1138.511 | 217 | 754 | 973 | 210 |
| Peroheron | 2/0-19 | 1.524 | 10.643 | 13.691 | 2/0-19 | 1138.511 | 220 | 754 | 976 | 210 |
| Mongolian | 3/0-7 | 1.524 | 11.786 | 14.834 | 3/0-7 | 1378.914 | 249 | 951 | 1199 | 242 |
| Hanoverian | 3/0-19 | 1.524 | 11.938 | 14.986 | 3/0-19 | 1378.914 | 251 | 951 | 1204 | 242 |
| Singlefoot | 4/0-7 | 1.524 | 13.259 | 16.307 | 4/0-7 | 1737.25 | 286 | 1199 | 1485 | 279 |
| Oldenburg | 4/0-19 | 1.524 | 13.411 | 16.459 | 4/0-19 | 1737.25 | 289 | 1199 | 1490 | 279 |
Frequently Asked Questions
1. What is a service drop cable?
A service drop cable is an overhead cable assembly used to supply electrical power from a utility distribution line or pole-mounted transformer to a consumer’s service entrance.
2. What is the difference between Duplex, Triplex and Quadruplex service drop cables?
Duplex, Triplex and Quadruplex refer to different service cable configurations. Duplex is commonly used for 120 V aerial service, Triplex for overhead connections from utility lines to a consumer’s weatherhead, and Quadruplex for three-phase service connections.
3. What voltage is the service drop cable designed for?
The supplied specifications cover service applications at 600 V or lower. The specific application and configuration should be confirmed against the project requirements.
4. What insulation materials are available?
The cable is available with polyethylene (PE) or cross-linked polyethylene (XLPE/XLP) insulation.
5. What is the maximum conductor operating temperature?
According to the supplied specifications, the maximum conductor temperature is 75°C for PE-insulated conductors and 90°C for XLPE/XLP-insulated conductors.
6. What materials are available for the neutral messenger?
The neutral messenger can be supplied in AAC, AAAC 6201-T81 aluminum alloy, or ACSR construction, depending on the selected design.
7. Which standards apply to service drop cables?
The supplied standards include ASTM B-230, ASTM B-231, ASTM B-232, ASTM B-399, ASTM B-901 and ANSI/ICEA S-76-474.
8. Can service drop cables be customized?
Yes. Cable configurations, conductor sizes, insulation materials and neutral messenger constructions can be specified according to project requirements and the available manufacturing range.
9. Are other conductor sizes available?
The supplied technical data indicates that other sizes are available upon request. Contact QZ Cable with your required specifications for confirmation.
10. What information is needed for a quotation?
Please provide the cable type (Duplex, Triplex or Quadruplex), conductor size, insulation material, neutral messenger construction, required quantity, applicable standard and destination port.
Certificate Display
Type and routine tests are issued from our own testing centre under the ISO 9001 quality system — test reports and certificates accompany every shipment.
Factory Tour
Why Choose Us
Packing & Shipping
- Wooden, steel or steel-wood drums; drum length to customer requirement
- Drum marking per customer / utility specification
- Both drum ends sealed and protected for sea freight
Ready for Your Next Cable Project?
Send us your specifications, cable schedule or RFQ — our engineering team replies with a technical proposal and price within one working day.
- Emailinfo@qzcablegroup.com
- WhatsApp / WeChat+86 173 3570 4553
- Contact personChloe · Export Department
- Factory addressWest Industrial Park, Zhulin Town, Gongyi City, Henan Province, China
Related products
AAAC AL7 Conductor – All Aluminium Alloy Conductor
AAAC conductor, AAAC AL7, AL7 conductor, AL7 aluminium alloy conductor, all aluminium alloy conductor, aluminium alloy overhead conductor, AAAC conductor manufacturer, EN 50182 conductor, overhead transmission conductor, overhead distribution conductor
AAAC (AL59) Conductor – High-Strength Aluminium Alloy Conductor
AAAC conductor, AAAC AL59, AL59 conductor, aluminum alloy conductor, all aluminium alloy conductor, AAAC conductor manufacturer, SS 424 08 14, SS EN 50182, overhead alloy conductor, stranded aluminum alloy conductor, grease filled AAAC conductor
AAC (AL1) – All Aluminium Conductor
AAC conductor, AAC conductor manufacturer, all aluminium conductor, AL1 conductor, AAC overhead conductor, bare aluminium conductor, aluminium stranded conductor, SS EN 50182, overhead distribution conductor, aluminium power conductor
AAAC — Aluminum Alloy Conductor
AAAC conductor, AAAC conductor manufacturer, all aluminum alloy conductor, AAAC cable, ASTM B399 AAAC, aluminum alloy overhead conductor, overhead transmission conductor, overhead distribution conductor, AAAC 6201, bare overhead conductor
AAC — All Aluminum Conductor
AAC conductor, AAC conductor manufacturer, all aluminium conductor, all aluminum conductor, AAC cable, aluminum stranded conductor, aluminium stranded conductor, Aluminum 1350-H19 conductor, ASTM B230, ASTM B231, AS/NZS 1531, DIN 48201 Part 5, GOST 839-80, BS 215-1, BS EN 50182, IEC 61089, bare overhead conductor, overhead distribution conductor.
ACSR — Aluminum Conductor Steel Reinforced
ACSR conductor, ACSR conductor manufacturer, ACSR cable, ACSR/AW conductor, ACSR/TW conductor, aluminum conductor steel reinforced, aluminum clad steel reinforced conductor, trapezoidal wire ACSR, overhead transmission conductor, bare overhead conductor, ASTM B232, ASTM B549, ASTM B779, IEC 61089.
ACAR — Aluminum Conductor, Aluminum-Alloy Reinforced
ACAR conductor, ACAR conductor manufacturer, aluminum alloy reinforced conductor, aluminum conductor alloy reinforced, 1350/6201 conductor, ASTM B524 ACAR, overhead ACAR conductor, bare overhead conductor, overhead transmission conductor, aluminum alloy conductor
AACSR — Aluminum Alloy Conductor Steel Reinforced
AACSR conductor, AACSR conductor manufacturer, AACSR cable, AACSR/AW conductor, aluminum alloy conductor steel reinforced, aluminum alloy overhead conductor, aluminum clad steel reinforced conductor, 6201 aluminum alloy conductor, IEC 61089 conductor, ASTM B711 conductor, AS 3607 conductor, long span overhead conductor, high strength transmission conductor.
LV ABC Cable – Low Voltage Aerial Bundled Cable
LV ABC cable, low voltage aerial bundled cable, ABC cable manufacturer, overhead bundled conductor, Duplex ABC cable, Triplex ABC cable, Quadruplex ABC cable, 600V aerial cable, HDPE insulated cable
Covered Conductors Type CC & Type CCT – AS/NZS 3675
covered conductor, CC covered conductor, CCT covered conductor, AS/NZS 3675, covered overhead conductor, XLPE covered conductor, 11kV covered conductor, 22kV covered conductor, 33kV covered conductor, spacer cable conductor, overhead distribution conductor
PVC-Covered Aluminium Conductors – AAC & ACSR
PVC covered aluminium conductor, PVC covered conductor, PVC covered overhead wire, PVC covered AAC conductor, PVC covered ACSR conductor, PVC insulated aluminium conductor, stranded aluminium overhead conductor, PVC covered power line conductor, BS 6485 conductor, BS 215 conductor
Covered Aerial Medium Voltage Cable – Spacer Cable & Tree Wire
Tree Wire Cable, Spacer Cable, Medium Voltage Overhead Cable, Messenger Supported Spacer Cable, Covered Overhead Conductor, Track Resistant XLPE Cable, XLPE Covered Conductor, ICEA S-121-733, AAC Tree Wire, AAAC Spacer Cable, ACSR Tree Wire
ACSR-OC, ACSR/AW-OC & ACSR/AW-TR/OC – Medium Voltage Aerial Insulated Conductors
ACSR-OC, ACSR/AW-OC, ACSR/AW-TR/OC, ACSR-OC cable manufacturer, ACSR/AW insulated conductor, 6.6kV aerial insulated conductor, 22.9kV overhead cable, XLPE insulated ACSR, aluminum clad steel reinforced conductor, KS C 3138, ES-6145-0021, medium voltage aerial conductor
A3CS / AAACS Cable 12/20 kV – XLPE Insulated Aluminium Cable
A3CS cable, AAACS cable, A3CS cable manufacturer, AAACS cable manufacturer, 12/20 kV cable, 20 kV aluminium cable, XLPE insulated aluminium cable, medium voltage aluminium cable, SPLN 41-10 cable, Indonesia medium voltage cable
600V Covered Overhead Line Wire – AAC, AAAC & ACSR
600V covered conductor, covered overhead line wire, covered line wire manufacturer, AAC covered conductor, AAAC covered conductor, ACSR covered conductor, aluminium covered conductor, LDPE covered conductor, HDPE covered conductor, XLPE covered conductor, overhead secondary distribution wire
Related solutions
Power Generation Cable Solutions
QZ Cable supplies power generation cable solutions for thermal, hydro, solar and wind power projects, including LV/MV power cables, control cables, instrumentation cables and overhead conductors.
Power Transmission Cable Solutions
QZ Cable supplies power transmission solutions, including AAC, AAAC, ACSR, ACSS, TACSR, TAAAC, OPGW and ADSS for utility, grid expansion and EPC projects worldwide.
Power Distribution Cable Solutions
Qingzhou Cable provides low- and medium-voltage cable solutions for electrical distribution networks, supporting power delivery from substations to commercial, industrial and residential users.
Power Substation Cable Solutions
Solar & Renewable Energy Cable Solutions