AER — cable
- 1 Solid or stranded aluminium conductor PE or XLPE insulation 3 Messenger wire
Product Description
AER
0,6 1 kV
3 2 1
0.6/1kV PE insulated aerial power cables with aluminium conductor
|
Standards: SFS 2200, HD 626 S1 |
Application It ispreferred to use AER cables instead of uninsulated |
|
Technical Data |
conductors at low voltage networks. AER cables are |
|
|
Max. operating temperature |
: 90 °C |
especially used in areas where the cost of underground |
|
Max. short circuit temperature |
: 250 °C (max. 5 sec.) |
networks are expensive and also for electrification of rural |
|
Rated voltage |
: 0.6/1 kV |
areas like villages. |
Construction1 Solid or stranded aluminium conductor PE or XLPE insulation 3 Messenger wire |
||
Number OfConductorCross Section |
INSULATED WIRES |
MESSENGER WIRE |
FINISHED CABLE |
|||||||||
Conductorsize |
Numberofwires |
Diameterofconductors |
Resistanceof20 °C |
CurrentCarryingCapacity |
Resistanceof20 °C |
CurrentCarryingCapacity |
DiameterofMessengerWire |
MinimumTensileStrength |
MaximumResistance of20 °C |
App. Max.BundleDiameter |
App. NetWeight |
|
mm² |
mm² |
Adet |
mm |
ohm/km |
A |
mm² |
A |
mm |
kN |
ohm/km |
mm |
kg/km |
|
1×16+25 |
1×16 |
1 |
4.4 |
1.91 |
70 |
1×16 |
60 |
5.9 |
7.4 |
1.38 |
15 |
225 |
|
3×16+25 |
3×16 |
1 |
4.4 |
1.91 |
60 |
1×16 |
60 |
5.9 |
7.1 |
1.38 |
22 |
350 |
|
3×25+35 |
3×25 |
7 |
5.9 |
1.2 |
80 |
1×16 |
60 |
6.9 |
10.3 |
0.986 |
26 |
475 |
|
3×35+50 |
3×35 |
7 |
6.9 |
0.868 |
95 |
1×16 |
60 |
8.1 |
14.2 |
0.72 |
30 |
625 |
|
3×50+70 |
3×50 |
7 |
8.1 |
0.641 |
120 |
1×16 |
60 |
9.6 |
20.6 |
0.493 |
35 |
800 |
|
3×70+95 |
3×70 |
7 |
9.6 |
0.443 |
150 |
1×16 |
60 |
11.4 |
27.9 |
0.363 |
41 |
1100 |
|
4×16+25 |
4×16 |
1 |
4.4 |
1.91 |
60 |
1×16 |
60 |
5.9 |
7.4 |
1.38 |
25 |
410 |
|
4×25+35 |
4×25 |
7 |
5.9 |
1.2 |
80 |
1×16 |
60 |
6.9 |
10.3 |
0.986 |
30 |
610 |
|
4×35+50 |
4×35 |
7 |
6.9 |
0.868 |
95 |
1×16 |
60 |
8.1 |
14.2 |
0.72 |
34 |
810 |
|
4×50+70 |
4×50 |
7 |
8.1 |
0.641 |
120 |
1×16 |
60 |
9.6 |
20.6 |
0.493 |
40 |
1060 |
|
4×70+95 |
4×70 |
7 |
9.6 |
0.443 |
150 |
1×16 |
60 |
11.4 |
27.9 |
0.363 |
47 |
1420 |
3 2 1
0.6/1kV PE insulated aerial power cables with aluminium conductor
Low Voltage
|
Standards: SFS 2200, HD 626 S1 |
Application It ispreferred to use AER cables instead of uninsulated |
|
Technical Data |
conductors at low voltage networks. AER cables are |
|
|
Max. operating temperature |
: 90°C |
especially used in areas where the cost of underground |
|
Max. short circuit temperature |
: 250°C (max. 5 sec.) |
networks are expensive and also for electrification of rural |
|
Rated voltage |
: 0.6/1 kV |
areas like villages. |
Number OfConductorCrossSection |
INSULATED WIRES |
MESSENGER WIRE |
FINISHED CABLE |
|||||||||
Conductorsize |
Numberofwires |
Diameterofconductors |
Resistanceof 20 °C |
CurrentCarryingCapacity |
Numberofwires |
CurrentCarryingCapacity |
Diameter ofMessengerWire |
MinimumTensileStrenght |
MaximumResistanceof 20 °C |
App. Max.BundleDiameter |
App. NetWeight |
|
mm² |
mm² |
Adet |
mm |
ohm/km |
A |
mm² |
A |
mm |
kN |
ohm/km |
mm |
kg/km |
|
1×16 + 25 |
1×16 |
1 |
4.4 |
1.91 |
75 |
– |
– |
5.9 |
7.4 |
1.38 |
15 |
140 |
|
1×25+35 |
1×25 |
7 |
5.9 |
1.2 |
10 |
– |
– |
6.9 |
10.3 |
0.986 |
17 |
200 |
|
1×35+50 |
1×35 |
7 |
6.9 |
0.868 |
125 |
– |
– |
8.1 |
14.2 |
0.72 |
20 |
275 |
|
3×16+25 |
3×16 |
1 |
4.4 |
1.91 |
70 |
– |
– |
5.9 |
7.4 |
1.38 |
22 |
275 |
|
3×25+35 |
3×25 |
7 |
5.9 |
1.2 |
90 |
– |
– |
6.9 |
10.3 |
0.986 |
26 |
400 |
|
3×35+50 |
3×35 |
7 |
6.9 |
0.868 |
115 |
– |
– |
8.1 |
14.2 |
0.72 |
30 |
575 |
|
3×50+70 |
3×50 |
7 |
8.1 |
0.641 |
140 |
– |
– |
9.6 |
20.6 |
0.493 |
35 |
750 |
|
3×70+95 |
3×70 |
7 |
9.6 |
0.443 |
180 |
– |
– |
11.4 |
27.9 |
0.363 |
41 |
1050 |
|
3×120+95 |
3×120 |
19 |
12.8 |
0.253 |
250 |
– |
– |
11.4 |
27.9 |
0.363 |
47 |
1550 |
|
4×16+25 |
4×16 |
1 |
4.4 |
1.91 |
70 |
– |
– |
5.9 |
7.4 |
1.38 |
24 |
375 |
|
4×25+35 |
4×25 |
7 |
5.9 |
1.2 |
90 |
– |
– |
6.9 |
10.3 |
0.986 |
28 |
500 |
|
4×35+50 |
4×35 |
7 |
6.9 |
0.868 |
115 |
– |
– |
8.1 |
14.2 |
0.72 |
32 |
680 |
|
4×50+70 |
4×50 |
7 |
8.1 |
0.641 |
140 |
– |
– |
9.6 |
20.6 |
0.493 |
38 |
900 |
|
4×70+95 |
4×70 |
7 |
9.6 |
0.443 |
180 |
– |
– |
11.4 |
27.9 |
0.363 |
45 |
1350 |
Certificate Display
Type and routine tests are issued from our own testing centre under the ISO 9001 quality system — test reports and certificates accompany every shipment.
Factory Tour
Why Choose Us
Packing & Shipping
- Wooden, steel or steel-wood drums; drum length to customer requirement
- Drum marking per customer / utility specification
- Both drum ends sealed and protected for sea freight
Ready for Your Next Cable Project?
Send us your specifications, cable schedule or RFQ — our engineering team replies with a technical proposal and price within one working day.
- Emailinfo@qzcablegroup.com
- WhatsApp / WeChat+86 173 3570 4553
- Contact personChloe · Export Department
- Factory addressWest Industrial Park, Zhulin Town, Gongyi City, Henan Province, China
Related products
XS/LXS Overhead Aerial Bundle Cable – Copper & Aluminum Conductors
XS cable, LXS cable, XS LXS cable, aerial bundle cable, overhead aerial bundle cable, copper aerial cable, aluminum aerial cable, copper ABC cable, aluminum ABC cable, 0.6/1kV overhead cable, DMA C33-209 cable, XLPE aerial cable, low voltage overhead distribution cable
0.61k V LV ABC Cable Aerial Bundle Conductor
The aerial bundled cables designed for overhead distribution lines have all conductors made of aluminium 1350 and insulated with XLPE. Can be used for fixed installation as overhead power lines up to 1000 V incl.
ACSR-OC, ACSR/AW-OC & ACSR/AW-TR/OC – Medium Voltage Aerial Insulated Conductors
ACSR-OC, ACSR/AW-OC, ACSR/AW-TR/OC, ACSR-OC cable manufacturer, ACSR/AW insulated conductor, 6.6kV aerial insulated conductor, 22.9kV overhead cable, XLPE insulated ACSR, aluminum clad steel reinforced conductor, KS C 3138, ES-6145-0021, medium voltage aerial conductor
SAC Spaced Aerial Cable Manufacturer – AAC Spacer Cable | ICEA S-66-524
SAC cable, spaced aerial cable, SAC cable manufacturer, spacer cable, AAC spacer cable, overhead spacer cable, 15kV SAC cable, 25kV SAC cable, 35kV SAC cable, XLPE XLPE cable, XLPE HDPE cable, ICEA S-66-524
Related solutions
Power Generation Cable Solutions
QZ Cable supplies power generation cable solutions for thermal, hydro, solar and wind power projects, including LV/MV power cables, control cables, instrumentation cables and overhead conductors.
Power Transmission Cable Solutions
QZ Cable supplies power transmission solutions, including AAC, AAAC, ACSR, ACSS, TACSR, TAAAC, OPGW and ADSS for utility, grid expansion and EPC projects worldwide.
Power Distribution Cable Solutions
Qingzhou Cable provides low- and medium-voltage cable solutions for electrical distribution networks, supporting power delivery from substations to commercial, industrial and residential users.
Power Substation Cable Solutions
Solar & Renewable Energy Cable Solutions