Bare Copper Conductor
Bare Copper Conductor Stranded
- ASTM B8 · BS 7884 · IEC 60228
Product Description
Bare Copper Conductor Stranded
Hard, Medium-Hard, or Soft-Drawn
Used for grounding purposes in accordance with the National Electrical Code (NEC). Soft-drawn solid or stranded conductors are used for grounding connections in circuits, machinery, equipment, and counterpoise grounding systems. Hard-drawn conductors are suitable for overhead transmission and distribution lines and specified grounding applications. Also available tinned.
Physical Data
| Bare Copper Conductors Stranded | ||||||||
|---|---|---|---|---|---|---|---|---|
| Size | Area | Class A | Class B | Net Weight | dc Resistance* | |||
| AWG | kcmil | cmil | Number of | OD | Number of | OD | lb/kft | |
| Strands | in | Strands | in | 20 °C | ||||
| 14 | — | 4110 | — | — | 7 | 0.0726 | 13 | 2.58 |
| 12 | — | 6530 | — | — | 7 | 0.0915 | 20 | 1.63 |
| 10 | — | 10380 | — | — | 7 | 0.116 | 32 | 1.02 |
| 8 | — | 16510 | — | — | 7 | 0.146 | 51 | 0.64 |
| 6 | — | 26240 | — | — | 7 | 0.184 | 81 | 0.403 |
| 4 | — | 41740 | 7 | 0.232 | 7 | 0.232 | 129 | 0.253 |
| 3 | — | 52620 | 7 | 0.26 | 7 | 0.26 | 163 | 0.201 |
| 2 | — | 66360 | 7 | 0.292 | 7 | 0.292 | 205 | 0.159 |
| 1 | — | 83690 | 7 | 0.328 | 19 | 0.332 | 258 | 0.127 |
| 1/0 | — | 105600 | 7 | 0.368 | 19 | 0.373 | 326 | 0.1 |
| 2/0 | — | 133100 | 7 | 0.414 | 19 | 0.419 | 411 | 0.795 |
| 3/0 | — | 167800 | 7 | 0.464 | 19 | 0.47 | 518 | 0.063 |
| 4/0 | — | 211600 | 7 | 0.522 | 19 | 0.528 | 653 | 0.05 |
| — | 250 | 250000 | 19 | 0.574 | 37 | 0.575 | 772 | 0.0423 |
| — | 300 | 300000 | 19 | 0.629 | 37 | 0.63 | 926 | 0.0353 |
| — | 350 | 350000 | 19 | 0.679 | 37 | 0.681 | 1081 | 0.0302 |
| — | 400 | 400000 | 19 | 0.726 | 37 | 0.728 | 1235 | 0.0264 |
| — | 450 | 450000 | 37 | 0.772 | 37 | 0.772 | 1389 | 0.0235 |
| — | 500 | 500000 | 37 | 0.813 | 37 | 0.813 | 1544 | 0.0192 |
| — | 600 | 600000 | 37 | 0.891 | 61 | 0.893 | 1883 | 0.0177 |
| — | 750 | 750000 | 61 | 0.998 | 61 | 0.998 | 2316 | 0.0141 |
| — | 1000 | 100000 | 61 | 1.152 | 61 | 1.152 | 3088 | 0.0106 |
| — | 1250 | 125000 | 61 | 1.288 | 91 | 1.289 | 3859 | 0.0085 |
| — | 1500 | 150000 | 61 | 1.411 | 91 | 1.412 | 4631 | 0.0071 |
| — | 1750 | 175000 | 91 | 1.526 | 127 | 1.526 | 5403 | 0.006 |
| — | 2000 | 200000 | 91 | 1.63 | 127 | 1.632 | 6175 | 0.0053 |
| The above data are approximate and subject to normal manufacturing tolerances. Where required, the compatibility with glands, connectors and accessories should be verified using actual dimensions of the product. Other sizes available upon request. *Direct current resistances apply to Class B, C, and D stranding. | ||||||||
| Bare Copper Conductors Stranded (cont.) | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| Breaking Strength | |||||||||
| Size | Strands | Hard Drawn Rated Strength |
dc Resistance @ 20 °C |
Medium-Hard Drawn Rated Strength |
dc Resistance @ 20 °C |
Soft Drawn (Annealed) Rated Strength |
dc Resistance @ 20 °C |
Allowable Ampacity † |
|
| AWG | kcmil | lb | Ω/kft | lb | Ω/kft | lb | Ω/kft | ||
| 14 | — | 7 | 197 | 2.679 | 158 | 2.665 | — | — | — |
| 12 | — | 7 | 311 | 1.685 | 248 | 1.676 | — | — | — |
| 10 | — | 7 | 492 | 1.06 | 389 | 1.054 | — | — | — |
| 8 | — | 7 | 777 | 0.6663 | 610 | 0.6629 | 499 | 0.6408 | 98 |
| 6 | — | 7 | 1228 | 0.4191 | 959 | 0.4169 | 794 | 0.403 | 124 |
| 4 | — | 7 | 1938 | 0.2636 | 1505 | 0.2622 | 1320 | 0.2534 | 155 |
| 3 | — | 7 | 2433 | 0.209 | 1885 | 0.2079 | 1670 | 0.201 | — |
| 2 | — | 7 | 3050 | 0.166 | 2360 | 0.165 | 2110 | 0.1578 | 209 |
| 1 | — | 7 | 3801 | 0.1316 | 2955 | 0.1309 | 2552 | 0.1252 | — |
| 1/0 | — | 7 | 4752 | 0.1042 | 3705 | 0.1037 | 3221 | 0.1002 | 282 |
| 2/0 | — | 7 | 5926 | 0.08267 | 4640 | 0.08224 | 4062 | 0.07949 | 329 |
| 3/0 | — | 7 | 7366 | 0.06556 | 5812 | 0.06522 | 5118 | 0.06304 | 382 |
| 4/0 | — | 7 | 9154 | 0.05199 | 7278 | 0.05172 | 6459 | 0.04999 | 444 |
| 4/0 | — | 19 | 9617 | 0.05199 | 7479 | 0.05172 | 6453 | 0.04999 | 444 |
| — | 250 | 19 | 11360 | 0.044 | 8836 | 0.04378 | 7627 | 0.04231 | 494 |
| — | 250 | 37 | 11600 | 0.044 | 8952 | 0.04378 | 7940 | 0.04231 | 494 |
| — | 300 | 19 | 13510 | 0.03667 | 10530 | 0.03648 | 9160 | 0.03526 | 556 |
| — | 350 | 19 | 15590 | 0.03143 | 12200 | 0.03127 | 10680 | 0.03022 | — |
| — | 500 | 37 | 22510 | 0.022 | 17550 | 0.02189 | 15240 | 0.02116 | 773 |
| — | 600 | 37 | 27020 | 0.01834 | 21060 | 0.01825 | 18300 | 0.01763 | — |
| — | 750 | 61 | 34090 | 0.01467 | 26510 | 0.01459 | 22890 | 0.0141 | 1000 |
| — | 1000 | 61 | 45030 | 0.011 | 35100 | 0.01094 | 30500 | 0.01058 | 1193 |
| † Ampacity per NEC table 310.15 (B) (21) based on 80°C Conductor Temperature, 40°C Ambient Temperature, 2ft/s Wind in Sun. | |||||||||
Applicable Standards
Certificate Display
Type and routine tests are issued from our own testing centre under the ISO 9001 quality system — test reports and certificates accompany every shipment.
Factory Tour
Why Choose Us
Packing & Shipping
- Wooden, steel or steel-wood drums; drum length to customer requirement
- Drum marking per customer / utility specification
- Both drum ends sealed and protected for sea freight
Ready for Your Next Cable Project?
Send us your specifications, cable schedule or RFQ — our engineering team replies with a technical proposal and price within one working day.
- Emailinfo@qzcablegroup.com
- WhatsApp / WeChat+86 173 3570 4553
- Contact personChloe · Export Department
- Factory addressWest Industrial Park, Zhulin Town, Gongyi City, Henan Province, China
Related products
CCS — Copper Clad Steel Conductor
Copper clad steel wire is composed of stranded copper clad monofilament, widely applied for grounding and lightning protection, electrostatic grounding protection, protective grounding, grounding wire of electrical and petrochemical system in areas covering high-frequency coaxial cable, electrified…
AAAC — Aluminum Alloy Conductor
AAAC- The full name: All aluminium alloy conductor. AAAC contains a small percentage (about 0.6%) of silicon and magnesium elements. It provides several benefits for overhead lines.
AACSR — Aluminum Alloy Conductor Steel Reinforced
The all aluminum alloy conductor steel reinforced is used for the power transmission lines with large span length installed under various severe weather conditions like snow, ice, storms, and so on. AACSR offers optimal strength for line design. Variable steel core stranding enables the desired…
ACAR — Aluminum Conductor Alloy Reinforced
ACAR – The full name: Aluminium Conductor Alloy Reinforced Aluminum Conductors. Aluminum conductor alloy (6201) reinforced (ACAR) is used as bare overhead transmission and both primary and secondary distribution cable. A good strength to weight ratio make ACAR a preferred choice for lines where…
Related solutions
Power Distribution Cable Solutions
Qingzhou Cable provides low- and medium-voltage cable solutions for electrical distribution networks, supporting power delivery from substations to commercial, industrial and residential users.
Power Substation Cable Solutions
Solar & Renewable Energy Cable Solutions
Building & Infrastructure Cable Solutions
Mining Cable Solutions