One-stop Solution for Wire & Cable · Since 1969
CCST (BLL) Covered Conductor – 10–52 kV | EN 50397-1
LV & MV Aerial Cables

CCST (BLL) Covered Conductor – 10–52 kV | EN 50397-1

PE Insulated Covered Conductor, HDPE Sheathed Overhead Conductor, Longitudinally Water-Blocked Conductor, Medium Voltage Covered Conductor, AAAC Covered Conductor, ACSR Covered Conductor, ACSC Covered Conductor, EN 50397-1 Covered Conductor, Water-Blocked Overhead Cable

  • Longitudinally Water-Blocked Design
  • AAAC / ACSR / ACSC Conductor Options
  • Semi-Conductive Screen & PE Insulation
  • UV-Resistant HDPE Outer Sheath | 10–52 kV Design Options | EN 50397-1
  • Customized Specifications | Direct Factory Supply | MOQ: 10KM

Product Overview

CCST (BLL) Covered Conductor is a medium-voltage covered overhead conductor designed for reliable power distribution networks operating at 10–52 kV. It features a round-stranded, non-compacted conductor with longitudinal water-blocking protection and a three-layer extruded covering system, providing enhanced protection against moisture ingress, corrosion, and environmental exposure.

The conductor incorporates extruded polymer water-blocking layers between individual conductor layers to prevent longitudinal water penetration. Its integrated manufacturing process combines conductor water blocking with the extrusion of three functional layers, ensuring consistent construction quality and reliable electrical performance.

The outer HDPE sheath is UV-resistant and provides additional protection against sunlight, weathering, and environmental stress. A semiconductive layer and PE insulation contribute to the electrical protection system, making CCST suitable for demanding outdoor overhead line applications.

CCST is available in FeAl conductor designs and AlMgSi alloy (Al7) configurations. Depending on project requirements, conductor constructions can include AAAC, ACSR, and ACSC. Standard conductor dimensions and customized specifications are available, with green, grey, and black sheath options.

Manufactured and tested in accordance with EN 50397-1 and SS 424 14 64, CCST offers a reliable solution for medium-voltage overhead power distribution systems.

Applications

CCST covered conductors are primarily used in medium-voltage overhead power distribution networks where additional protection against environmental exposure and moisture penetration is required.

Typical applications include:

  • Medium-voltage overhead distribution lines (10–52 kV).
  • Urban and suburban power distribution networks.
  • Overhead lines in areas exposed to moisture and harsh weather.
  • Distribution networks requiring longitudinal water-blocking protection.
  • Power infrastructure projects requiring durable covered conductors.

Applicable Standards

EN 50397-1 – Covered Conductors for Overhead Lines and the Related Accessories for Rated Voltages Above 1 kV AC and Not Exceeding 36 kV AC.

Additional references may include:

  • EN 50182 – Conductors for Overhead Lines: Round Wire Concentric Lay Stranded Conductors.
  • IEC 60228 – Conductors of Insulated Cables, where applicable.
  • SS 424 14 64 – Swedish technical reference associated with this product family.

Important: EN 50397-1 covers the specified voltage range up to 36 kV AC. A 52 kV design must be evaluated against its own applicable standards and testing requirements; it must not automatically be declared compliant with EN 50397-1.

Key Features & Advantages

  • Longitudinal Water Blocking: Extruded polymer between conductor layers helps prevent water ingress along the conductor.
  • Three-Layer Extruded Design: Integrated manufacturing ensures consistent layer construction and product quality.
  • UV-Resistant Outer Sheath: HDPE outer protection provides resistance to sunlight and environmental exposure.
  • Multiple Conductor Options: Available in AAAC, ACSR, and ACSC constructions.
  • Non-Compacted Round-Wire Design: Maintains a conventional round-stranded conductor construction.
  • Outdoor Durability: Designed for long-term use in medium-voltage overhead distribution networks.
  • Customized Solutions: Available in different conductor sizes, materials, and sheath colors.
  • Product Traceability: Permanent marking includes manufacturer, conductor type, voltage designation, applicable standard, production date, and meter marking.

Technical Specifications

ItemDescription
Product TypeCCST (BLL) Covered Conductor
Rated Voltage10–52 kV
Conductor ConstructionRound-stranded, non-compacted
Conductor MaterialsFeAl / AlMgSi (Al7)
Conductor TypesAAAC, ACSR, ACSC
Water BlockingLongitudinal water-blocked
InsulationPE
Semiconductive LayerYes, extruded
Outer SheathHDPE
Maximum Operating Temperature+70°C
Outer Sheath ColorsGreen, Grey, Black
Bending Radius – Cable Extraction15 × OD
Bending Radius – Final Fixed Installation10 × OD
Manufacturing StandardEN 50397-1
Additional StandardSS 424 14 64
MarkingManufacturer / Type / Voltage / Standard / Year-Month / Meter Marking

Note: Final conductor configuration, voltage designation, dimensions, and layer thickness should be confirmed according to the applicable project specification and approved technical drawings.

NameCross section [mm3]Outer diameter [mm]Total weight [kg/km]AC voltage ratingNumber of strands [pcs]Strand diameter [mm]
CCST 35 AL7 20(24)kV W3512.718220(24)kV72.5
CCST 50 AL7 20(24)kV W5014.4424720(24)kV73.08
CCST 50 AL7 30(36)kV W5016.4429230(36)kV73.08
CCST 50 AL7 52kV W5017.8433152kV73.08
CCST 62 ACSR 20(24)kV W6215.3133120(24)kV73.37
CCST 62 AL7 20(24)kV W6215.3128520(24)kV73.37
CCST 70 AL7 20(24)kV W7015.9131320(24)kV73.57
CCST 70 AL7 30(36)kV W7017.9136230(36)kV73.57
CCST 70 AL7 52kV W7019.3140452kV73.57
CCST 99 ACSR 20(24)kV W9917.9548920(24)kV74.25
CCST 99 ACSR 52kV W9921.3558752kV74.25
CCST 99 AL7 20(24)kV W9917.9541720(24)kV74.25
CCST 99 AL7 52kV W9921.3553052kV74.25
CCST 120 AL7 20(24)kV W12019.450620(24)kV192.84
CCST 159 AL7 20(24)kV W15921.563520(24)kV193.26
CCST 159 AL7 52kV W15924.975152kV193.26
CCST 185 AL7 20(24)kV W18522.873020(24)kV193.52
CCST 241 AL7 20(24)kV W24125.392020(24)kV194.02
CCST 241 AL7 30(36)kV W24127.399730(36)kV194.02
CCST 241 AL7 33kV W24127.96102333kV194.02
CCST 241 AL7 52kV W24128.7107752kV194.02
CCST 329 AL7 20(24)kV W32928.8124420(24)kV373.37
CCST 329 AL7 33kV W32931.45134633kV373.37
CCST 329 AL7 52kV W32932.19138852kV373.37

Frequently Asked Questions (FAQ)

1. What is a CCST (BLL) covered conductor?

CCST (BLL) is a medium-voltage covered overhead conductor featuring longitudinal water blocking and a three-layer extruded protection system. It is designed to improve moisture resistance and environmental durability in overhead distribution networks.

2. What voltage ratings are available for CCST conductors?

CCST covered conductors are designed for voltage applications from 10 kV to 52 kV, depending on the specific construction and project requirements.

3. What conductor materials are available?

CCST can be manufactured with different conductor designs, including FeAl and AlMgSi (Al7), as well as AAAC, ACSR, and ACSC configurations, subject to the selected design.

4. What is the purpose of longitudinal water blocking?

Longitudinal water blocking helps prevent water from traveling along the conductor through the spaces between conductor layers, reducing the risk of moisture-related deterioration and corrosion.

5. What materials are used for the insulation and outer sheath?

The construction includes PE insulation, an extruded semiconductive layer, and an HDPE outer sheath.

6. What is the maximum operating temperature of CCST?

The maximum continuous operating temperature specified for CCST is +70°C.

7. What standards does CCST comply with?

CCST is manufactured and tested in accordance with EN 50397-1 and SS 424 14 64.

8. Can CCST covered conductors be customized?

Yes. Conductor materials, cross-sectional areas, voltage ratings, construction details, and outer sheath colors can be specified according to project requirements.

Certificate Display

ISO 9001 Quality Management System
ISO 9001 Certificate (2025–2028)
ISO 9001 Certificate (NOA)
CE — Verification of Conformity
RoHS Compliance Attestation (EU)
Low Voltage Directive Attestation (EU)

Type and routine tests are issued from our own testing centre under the ISO 9001 quality system — test reports and certificates accompany every shipment.

Factory Tour

Why Choose Us

50+ years of experience Trusted manufacturing expertise since 1969
International standards IEC, ASTM, BS, CSA and other global standards
Strict quality control Comprehensive testing throughout production
Large production capacity Reliable supply for utility and EPC projects
Fast global delivery Efficient manufacturing and worldwide shipping
Technical support Expert assistance from inquiry to project completion

Packing & Shipping

  • Wooden, steel or steel-wood drums; drum length to customer requirement
  • Drum marking per customer / utility specification
  • Both drum ends sealed and protected for sea freight
Get in touch

Ready for Your Next Cable Project?

Send us your specifications, cable schedule or RFQ — our engineering team replies with a technical proposal and price within one working day.

  • Emailinfo@qzcablegroup.com
  • WhatsApp / WeChat+86 173 3570 4553
  • Contact personChloe · Export Department
  • Factory addressWest Industrial Park, Zhulin Town, Gongyi City, Henan Province, China

    The more specific the standard and size, the faster we can quote.

    Related products

    High Conductivity Aluminium Alloy Conductor (AAAC) – AL5, AL6, AL7, AL57, AL59 & Alloy 1120 high conductivity aluminium alloy conductor, AAAC conductor, AAAC manufacturer, AL5 conductor, AL6 conductor, AL7 conductor, AL57 conductor, AL59 conductor, Alloy 1120 conductor, high conductivity AAAC, aluminium alloy overhead conductor, overhead transmission conductor, BS EN 50182 AAAC AL7 Conductor – All Aluminium Alloy Conductor AAAC conductor, AAAC AL7, AL7 conductor, AL7 aluminium alloy conductor, all aluminium alloy conductor, aluminium alloy overhead conductor, AAAC conductor manufacturer, EN 50182 conductor, overhead transmission conductor, overhead distribution conductor AAAC (AL59) Conductor – High-Strength Aluminium Alloy Conductor AAAC conductor, AAAC AL59, AL59 conductor, aluminum alloy conductor, all aluminium alloy conductor, AAAC conductor manufacturer, SS 424 08 14, SS EN 50182, overhead alloy conductor, stranded aluminum alloy conductor, grease filled AAAC conductor AAC (AL1) – All Aluminium Conductor AAC conductor, AAC conductor manufacturer, all aluminium conductor, AL1 conductor, AAC overhead conductor, bare aluminium conductor, aluminium stranded conductor, SS EN 50182, overhead distribution conductor, aluminium power conductor AAAC — Aluminum Alloy Conductor AAAC conductor, AAAC conductor manufacturer, all aluminum alloy conductor, AAAC cable, ASTM B399 AAAC, aluminum alloy overhead conductor, overhead transmission conductor, overhead distribution conductor, AAAC 6201, bare overhead conductor AAC — All Aluminum Conductor AAC conductor, AAC conductor manufacturer, all aluminium conductor, all aluminum conductor, AAC cable, aluminum stranded conductor, aluminium stranded conductor, Aluminum 1350-H19 conductor, ASTM B230, ASTM B231, AS/NZS 1531, DIN 48201 Part 5, GOST 839-80, BS 215-1, BS EN 50182, IEC 61089, bare overhead conductor, overhead distribution conductor. ACSR — Aluminum Conductor Steel Reinforced ACSR conductor, ACSR conductor manufacturer, ACSR cable, ACSR/AW conductor, ACSR/TW conductor, aluminum conductor steel reinforced, aluminum clad steel reinforced conductor, trapezoidal wire ACSR, overhead transmission conductor, bare overhead conductor, ASTM B232, ASTM B549, ASTM B779, IEC 61089. ACAR — Aluminum Conductor, Aluminum-Alloy Reinforced ACAR conductor, ACAR conductor manufacturer, aluminum alloy reinforced conductor, aluminum conductor alloy reinforced, 1350/6201 conductor, ASTM B524 ACAR, overhead ACAR conductor, bare overhead conductor, overhead transmission conductor, aluminum alloy conductor AACSR — Aluminum Alloy Conductor Steel Reinforced AACSR conductor, AACSR conductor manufacturer, AACSR cable, AACSR/AW conductor, aluminum alloy conductor steel reinforced, aluminum alloy overhead conductor, aluminum clad steel reinforced conductor, 6201 aluminum alloy conductor, IEC 61089 conductor, ASTM B711 conductor, AS 3607 conductor, long span overhead conductor, high strength transmission conductor. CCSX-Hybrid Covered Conductor – XLPE Insulation & HDPE Sheath CCSX Hybrid, CCSX Hybrid cable, CCSX covered conductor, XLPE covered conductor, HDPE covered conductor, water blocked overhead conductor, AAAC covered conductor, ACSR covered conductor, EN 50397-1 CCSX (BLX) Covered Overhead Line Conductor – 10–52 kV CCSX cable, BLX covered conductor, CCSX conductor manufacturer, 10–52 kV covered conductor, water-blocked overhead conductor, EN 50397-1 cable, Al7 conductor, FeAl conductor SAC Spaced Aerial Cable Manufacturer – AAC Spacer Cable | ICEA S-66-524 SAC cable, spaced aerial cable, SAC cable manufacturer, spacer cable, AAC spacer cable, overhead spacer cable, 15kV SAC cable, 25kV SAC cable, 35kV SAC cable, XLPE XLPE cable, XLPE HDPE cable, ICEA S-66-524 Amka Cable Low Voltage Twsit Overhead Cable Amka Cable Low Voltage Twsit Overhead Cable AER — cable LV & MV Aerial Cables 0.61k V LV ABC Cable Aerial Bundle Conductor The aerial bundled cables designed for overhead distribution lines have all conductors made of aluminium 1350 and insulated with XLPE. Can be used for fixed installation as overhead power lines up to 1000 V incl.
    Inquiry WhatsApp Email