AER — cable
- 1 Solid or stranded aluminium conductor PE or XLPE insulation 3 Messenger wire
Product Description
AER
0,6 1 kV
3 2 1
0.6/1kV PE insulated aerial power cables with aluminium conductor
|
Standards: SFS 2200, HD 626 S1 |
Application It ispreferred to use AER cables instead of uninsulated |
|
Technical Data |
conductors at low voltage networks. AER cables are |
|
|
Max. operating temperature |
: 90 °C |
especially used in areas where the cost of underground |
|
Max. short circuit temperature |
: 250 °C (max. 5 sec.) |
networks are expensive and also for electrification of rural |
|
Rated voltage |
: 0.6/1 kV |
areas like villages. |
Construction1 Solid or stranded aluminium conductor PE or XLPE insulation 3 Messenger wire |
||
Number OfConductorCross Section |
INSULATED WIRES |
MESSENGER WIRE |
FINISHED CABLE |
|||||||||
Conductorsize |
Numberofwires |
Diameterofconductors |
Resistanceof20 °C |
CurrentCarryingCapacity |
Resistanceof20 °C |
CurrentCarryingCapacity |
DiameterofMessengerWire |
MinimumTensileStrength |
MaximumResistance of20 °C |
App. Max.BundleDiameter |
App. NetWeight |
|
mm² |
mm² |
Adet |
mm |
ohm/km |
A |
mm² |
A |
mm |
kN |
ohm/km |
mm |
kg/km |
|
1×16+25 |
1×16 |
1 |
4.4 |
1.91 |
70 |
1×16 |
60 |
5.9 |
7.4 |
1.38 |
15 |
225 |
|
3×16+25 |
3×16 |
1 |
4.4 |
1.91 |
60 |
1×16 |
60 |
5.9 |
7.1 |
1.38 |
22 |
350 |
|
3×25+35 |
3×25 |
7 |
5.9 |
1.2 |
80 |
1×16 |
60 |
6.9 |
10.3 |
0.986 |
26 |
475 |
|
3×35+50 |
3×35 |
7 |
6.9 |
0.868 |
95 |
1×16 |
60 |
8.1 |
14.2 |
0.72 |
30 |
625 |
|
3×50+70 |
3×50 |
7 |
8.1 |
0.641 |
120 |
1×16 |
60 |
9.6 |
20.6 |
0.493 |
35 |
800 |
|
3×70+95 |
3×70 |
7 |
9.6 |
0.443 |
150 |
1×16 |
60 |
11.4 |
27.9 |
0.363 |
41 |
1100 |
|
4×16+25 |
4×16 |
1 |
4.4 |
1.91 |
60 |
1×16 |
60 |
5.9 |
7.4 |
1.38 |
25 |
410 |
|
4×25+35 |
4×25 |
7 |
5.9 |
1.2 |
80 |
1×16 |
60 |
6.9 |
10.3 |
0.986 |
30 |
610 |
|
4×35+50 |
4×35 |
7 |
6.9 |
0.868 |
95 |
1×16 |
60 |
8.1 |
14.2 |
0.72 |
34 |
810 |
|
4×50+70 |
4×50 |
7 |
8.1 |
0.641 |
120 |
1×16 |
60 |
9.6 |
20.6 |
0.493 |
40 |
1060 |
|
4×70+95 |
4×70 |
7 |
9.6 |
0.443 |
150 |
1×16 |
60 |
11.4 |
27.9 |
0.363 |
47 |
1420 |
3 2 1
0.6/1kV PE insulated aerial power cables with aluminium conductor
Low Voltage
|
Standards: SFS 2200, HD 626 S1 |
Application It ispreferred to use AER cables instead of uninsulated |
|
Technical Data |
conductors at low voltage networks. AER cables are |
|
|
Max. operating temperature |
: 90°C |
especially used in areas where the cost of underground |
|
Max. short circuit temperature |
: 250°C (max. 5 sec.) |
networks are expensive and also for electrification of rural |
|
Rated voltage |
: 0.6/1 kV |
areas like villages. |
Number OfConductorCrossSection |
INSULATED WIRES |
MESSENGER WIRE |
FINISHED CABLE |
|||||||||
Conductorsize |
Numberofwires |
Diameterofconductors |
Resistanceof 20 °C |
CurrentCarryingCapacity |
Numberofwires |
CurrentCarryingCapacity |
Diameter ofMessengerWire |
MinimumTensileStrenght |
MaximumResistanceof 20 °C |
App. Max.BundleDiameter |
App. NetWeight |
|
mm² |
mm² |
Adet |
mm |
ohm/km |
A |
mm² |
A |
mm |
kN |
ohm/km |
mm |
kg/km |
|
1×16 + 25 |
1×16 |
1 |
4.4 |
1.91 |
75 |
– |
– |
5.9 |
7.4 |
1.38 |
15 |
140 |
|
1×25+35 |
1×25 |
7 |
5.9 |
1.2 |
10 |
– |
– |
6.9 |
10.3 |
0.986 |
17 |
200 |
|
1×35+50 |
1×35 |
7 |
6.9 |
0.868 |
125 |
– |
– |
8.1 |
14.2 |
0.72 |
20 |
275 |
|
3×16+25 |
3×16 |
1 |
4.4 |
1.91 |
70 |
– |
– |
5.9 |
7.4 |
1.38 |
22 |
275 |
|
3×25+35 |
3×25 |
7 |
5.9 |
1.2 |
90 |
– |
– |
6.9 |
10.3 |
0.986 |
26 |
400 |
|
3×35+50 |
3×35 |
7 |
6.9 |
0.868 |
115 |
– |
– |
8.1 |
14.2 |
0.72 |
30 |
575 |
|
3×50+70 |
3×50 |
7 |
8.1 |
0.641 |
140 |
– |
– |
9.6 |
20.6 |
0.493 |
35 |
750 |
|
3×70+95 |
3×70 |
7 |
9.6 |
0.443 |
180 |
– |
– |
11.4 |
27.9 |
0.363 |
41 |
1050 |
|
3×120+95 |
3×120 |
19 |
12.8 |
0.253 |
250 |
– |
– |
11.4 |
27.9 |
0.363 |
47 |
1550 |
|
4×16+25 |
4×16 |
1 |
4.4 |
1.91 |
70 |
– |
– |
5.9 |
7.4 |
1.38 |
24 |
375 |
|
4×25+35 |
4×25 |
7 |
5.9 |
1.2 |
90 |
– |
– |
6.9 |
10.3 |
0.986 |
28 |
500 |
|
4×35+50 |
4×35 |
7 |
6.9 |
0.868 |
115 |
– |
– |
8.1 |
14.2 |
0.72 |
32 |
680 |
|
4×50+70 |
4×50 |
7 |
8.1 |
0.641 |
140 |
– |
– |
9.6 |
20.6 |
0.493 |
38 |
900 |
|
4×70+95 |
4×70 |
7 |
9.6 |
0.443 |
180 |
– |
– |
11.4 |
27.9 |
0.363 |
45 |
1350 |
Certificate Display
Type and routine tests are issued from our own testing centre under the ISO 9001 quality system — test reports and certificates accompany every shipment.
Factory Tour
Why Choose Us
Packing & Shipping
- Wooden, steel or steel-wood drums; drum length to customer requirement
- Drum marking per customer / utility specification
- Both drum ends sealed and protected for sea freight
Ready for Your Next Cable Project?
Send us your specifications, cable schedule or RFQ — our engineering team replies with a technical proposal and price within one working day.
- Emailinfo@qzcablegroup.com
- WhatsApp / WeChat+86 173 3570 4553
- Contact personChloe · Export Department
- Factory addressWest Industrial Park, Zhulin Town, Gongyi City, Henan Province, China
Related products
Cable Autoportante
NTP 370.254 ICEA S-76-474 Cable Autoportante CAAI CAAI-S
TYIR — Bundled Overhead Line Cable
TYIR / TYIR 50 OL-AL PVC Bundled Overhead Line Cable
NF2X — Aerial Bundled Twisted Cable
NF2X/NFA2X Aerial Bundled Twisted Cable
ABNT — 0.61k V Preassembled Cabos De Alumínio Multiplexado
ABNT NBR 8182 0.6/1kV Preassembled Cabos De Alumínio Multiplexado
Related solutions
Power Distribution Cable Solutions
Qingzhou Cable provides low- and medium-voltage cable solutions for electrical distribution networks, supporting power delivery from substations to commercial, industrial and residential users.
Power Substation Cable Solutions
Solar & Renewable Energy Cable Solutions
Building & Infrastructure Cable Solutions
Mining Cable Solutions