AMKA Cable Low Voltage Twisted Overhead Cable
AMKA cable, AMKA aerial bundled cable, AMKA-T cable, AMKA-X cable, AMK-T cable, AMK-X cable, low voltage ABC cable, aluminium aerial cable, overhead bundled conductor, HDPE insulated aerial cable, XLPE insulated aerial cable
- Aluminium Conductor | PE / HDPE / XLPE Insulation
- AMKA, AMKA-T & AMKA-X | AMK-T & AMK-X
- Bare or Insulated Messenger Options
- For Low-Voltage Overhead Power Distribution
- Optional Street-Lighting Conductors
Product Overview
AMKA Low Voltage Aerial Bundled Cable is designed for low-voltage overhead power distribution networks. It consists of aluminium phase conductors insulated with weather-resistant polyethylene (PE), high-density polyethylene (HDPE), or cross-linked polyethylene (XLPE), depending on the cable type.
The insulated conductors are twisted around a supporting messenger conductor or laid up together as a self-supporting cable assembly. Depending on the design, the messenger may be bare or insulated aluminium alloy.
AMKA aerial bundled cables are available in different configurations, including AMKA, AMKA-T, AMKA-X, AMK-T and AMK-X, with options for phase conductors, street-lighting conductors and messenger construction.
Applications
AMKA aerial bundled cables are suitable for:
- Low-voltage overhead power distribution networks
- Urban and rural electricity distribution
- Overhead service connections
- Aerial distribution lines supported by messenger conductors
- Street-lighting power supply, where optional lighting conductors are included
Applicable Standards
The supplied product documentation lists the following standards:
- SFS 2200 – Aerial Bundled Cable AMKA
- HD 626 S1 – Overhead Distribution Cables
- IEC 60228 – Conductors of Insulated Cables
The applicable standard depends on the selected cable construction and project requirements.
Cable Construction
1. AMKA Cable
Conductor
- 16 mm²: Round, solid aluminium conductor
- 25–120 mm²: Round, stranded and compacted aluminium conductor
Insulation
Black, UV-resistant and weather-resistant PE compound.
Cable Design
The insulated phase conductors are laid up around the messenger conductor.
Core Identification
- Phase conductors: Identified by 2, 3 or 4 longitudinal ridges
- Optional conductors: May be supplied without ridges
Operating and Installation Temperatures
- Maximum conductor operating temperature: 70°C
- Minimum cable temperature during installation: -20°C
- Special precautions are recommended for installation below 0°C.
Mechanical and Electrical Characteristics
- UV resistance: Good
- Minimum bending radius during installation: 20 × D
- Minimum bending radius at final installation: 14 × D
- Maximum short-circuit temperature: 135°C for 5 seconds
Example of Cable Marking
AMKA 3×16+35 1 kV, followed by production number, date and time, and metre marking.
2. AMKA-T Cable
AMKA-T is an aerial bundled cable with HDPE insulation and a messenger conductor. It can include optional street-lighting conductors.
Phase Conductors
Round, stranded and compacted aluminium conductors.
Street-Lighting Conductors
A maximum of two optional conductors may be included:
- 16 mm²: Round, solid or round, stranded and compacted aluminium conductor
- 25 mm²: Round, stranded and compacted aluminium conductor
Messenger
Available in two constructions:
- Bare, round, stranded and compacted aluminium alloy conductor
- Insulated, round, stranded and uncompacted aluminium alloy conductor
Insulation
Extruded black, weather-resistant HDPE.
Cable Design
The cable consists of one, two or three insulated phase conductors and one or two optional insulated street-lighting conductors stranded around a bare or insulated messenger.
Other Characteristics
- Direction of lay: Right-hand lay (Z)
- Core identification: Longitudinal ridges
- Origin marking: Embossed on the phase conductor insulation, identifying the manufacturer, year of manufacture and insulation material
Key Advantage
The hardness of HDPE insulation provides good protection against mechanical damage.
3. AMKA-X Cable
AMKA-X features XLPE insulation for aerial bundled low-voltage distribution applications.
Phase Conductors
Round, stranded and compacted aluminium conductors.
Street-Lighting Conductors
A maximum of two optional conductors may be included:
- 16 mm²: Round, solid or round, stranded and compacted aluminium conductor
- 25 mm²: Round, stranded and compacted aluminium conductor
Messenger
Available in two constructions:
- Bare, round, stranded and compacted aluminium alloy conductor
- Insulated, round, stranded and uncompacted aluminium alloy conductor
Insulation
Extruded black, weather-resistant XLPE.
Cable Design
The cable consists of one, two or three insulated phase conductors and one or two optional insulated street-lighting conductors stranded around a bare or insulated messenger.
Other Characteristics
- Direction of lay: Right-hand lay (Z)
- Core identification: Longitudinal ridges
- Origin marking: Embossed on the phase conductor insulation, identifying the manufacturer, year of manufacture and insulation material
Key Advantage
XLPE insulation provides enhanced thermal performance and supports higher current-carrying capacity compared with the HDPE-insulated design, subject to the applicable cable rating and installation conditions.
4. AMK-T Cable
AMK-T is a twisted low-voltage aerial cable consisting of insulated aluminium conductors laid up together.
Conductor
Round, stranded and compacted aluminium conductor.
Insulation
Extruded black, weather-resistant HDPE.
Cable Design
The insulated conductors are stranded together.
Other Characteristics
- Direction of lay: Right-hand lay (Z)
- Core identification: Longitudinal ridges
- Origin marking: Embossed on the conductor insulation, identifying the manufacturer, year of manufacture and insulation material
Key Advantage
The hardness of HDPE insulation provides good protection against mechanical damage.
5. AMK-X Cable
AMK-X is an XLPE-insulated twisted aerial cable designed for low-voltage overhead distribution.
Conductor
Round, stranded and compacted aluminium conductor.
Insulation
Extruded black, weather-resistant XLPE.
Cable Design
The insulated conductors are stranded together.
Key Characteristics
- Core identification: Longitudinal ridges
- Origin marking: Embossed on the conductor insulation, identifying the manufacturer, year of manufacture and insulation material
- XLPE insulation supports higher current-carrying capacity, subject to the applicable cable rating and installation conditions
Technical Data
AMKA Cable – Dimensional and Weight Data
| Product Name | Diameter over Bare Conductor (mm) | Diameter over Messenger (mm) | Effective Diameter in Wind (mm) | Conductor Weight (kg/km) | Cable Weight (kg/km) |
|---|---|---|---|---|---|
| AMKA 1×16+25 | 4.4 | 5.8 | 11 | 100 | 135 |
| AMKA 3×16+25 | 4.4 | 5.8 | 20 | 185 | 270 |
| AMKA 3×25+35 | 5.8 | 6.8 | 23 | 285 | 390 |
| AMKA 3×35+50 | 6.8 | 8.0 | 27 | 390 | 530 |
| AMKA 3×50+70 | 8.0 | 9.6 | 31 | 540 | 700 |
| AMKA 3×70+95 | 9.6 | 11.3 | 36 | 775 | 1,000 |
| AMKA 3×120+95 | 12.7 | 11.3 | 42 | 1,185 | 1,500 |
Effective diameter in wind = circumference divided by π.
AMKA-T – Technical Data for Typical Constructions
| Technical Data | 1×16+16 | 3×16+25 | 3×25+25 | 3×35+25 | 3×50+35 | 3×70+50 | 3×95+70 | 3×120+70 | 3×150+70 |
|---|---|---|---|---|---|---|---|---|---|
| Phase conductor diameter, approx. (mm) | 4.7 | 4.7 | 5.8 | 6.8 | 8.0 | 9.6 | 11.3 | 12.7 | 14.1 |
| Insulated phase conductor diameter, approx. (mm) | 6.7 | 6.7 | 7.8 | 8.8 | 10.4 | 12.4 | 14.1 | 15.9 | 17.7 |
| Messenger diameter, approx. (mm) | 4.7/5.1 | 5.8/6.3 | 5.8/6.3 | 5.8/6.3 | 6.8/7.5 | 8.0/8.7 | 9.6/10.4 | 9.6/10.4 | 9.6/10.4 |
| Insulated messenger diameter, approx. (mm) | -/7.1 | -/8.3 | -/8.3 | -/8.3 | -/9.5 | -/11.1 | -/13.2 | -/13.2 | -/13.2 |
| Overall cable diameter, approx. (mm) | 12/15 | 20/23 | 23/25 | 25/27 | 29/31 | 34/37 | 39/43 | 43/46 | 46/50 |
| Complete cable weight, approx. (kg/km) | 105/130 | 250/275 | 340/370 | 430/455 | 590/625 | 840/890 | 1,150/1,250 | 1,400/1,500 | 1,700/1,750 |
| Minimum messenger breaking load (kN) | 4.7 | 7.4 | 7.4 | 7.4 | 10.3 | 14.2 | 20.6 | 20.6 | 20.6 |
| Conductor DC resistance at +20°C (Ω/km) | 1.91 | 1.91 | 1.20 | 0.868 | 0.641 | 0.443 | 0.320 | 0.253 | 0.206 |
| Messenger DC resistance at +20°C (Ω/km) | 2.20 | 1.38 | 1.38 | 1.38 | 0.986 | 0.720 | 0.493 | 0.493 | 0.493 |
| Thermal short-circuit current capacity for 1 s (kA) | 1.1 | 1.1 | 1.7 | 1.7 | 2.3 | 3.4 | 4.7 | 4.7 | 4.7 |
For messenger diameter, insulated messenger diameter, overall cable diameter and cable weight, paired values are reproduced in the same order as supplied in the source data.
AMKA-X – Technical Data for Typical Constructions
| Technical Data | 1×16+16 | 3×16+25 | 3×25+25 | 3×35+25 | 3×50+35 | 3×70+50 | 3×95+70 | 3×120+70 | 3×150+70 |
|---|---|---|---|---|---|---|---|---|---|
| Phase conductor diameter, approx. (mm) | 4.7 | 4.7 | 5.8 | 6.8 | 8.0 | 9.6 | 11.3 | 12.7 | 14.1 |
| Insulated phase conductor diameter, approx. (mm) | 7.3 | 7.3 | 8.4 | 9.4 | 11.0 | 12.6 | 14.7 | 16.1 | 17.5 |
| Messenger diameter, approx. (mm) | 4.7/5.1 | 5.8/6.3 | 5.8/6.3 | 5.8/6.3 | 6.8/7.5 | 8.0/8.7 | 9.6/10.4 | 9.6/10.4 | 9.6/10.4 |
| Insulated messenger diameter, approx. (mm) | -/7.7 | -/8.9 | -/8.9 | -/8.9 | -/10.1 | -/11.7 | -/13.4 | -/13.4 | -/13.4 |
| Overall cable diameter, approx. (mm) | 13/16 | 22/25 | 24/27 | 26/29 | 30/33 | 34/38 | 40/44 | 43/47 | 46/50 |
| Complete cable weight, approx. (kg/km) | 110/140 | 265/300 | 360/395 | 450/485 | 620/660 | 850/910 | 1,200/1,250 | 1,450/1,500 | 1,700/1,750 |
| Minimum messenger breaking load (kN) | 4.7 | 7.4 | 7.4 | 7.4 | 10.3 | 14.2 | 20.6 | 20.6 | 20.6 |
| Conductor DC resistance at +20°C (Ω/km) | 1.91 | 1.91 | 1.20 | 0.868 | 0.641 | 0.443 | 0.320 | 0.253 | 0.206 |
| Messenger DC resistance at +20°C (Ω/km) | 2.20 | 1.38 | 1.38 | 1.38 | 0.986 | 0.720 | 0.493 | 0.493 | 0.493 |
| Thermal short-circuit current capacity for 1 s (kA) | 1.3 | 1.5 | 2.0 | 2.0 | 2.8 | 4.0 | 5.6 | 5.6 | 5.6 |
For messenger diameter, insulated messenger diameter, overall cable diameter and cable weight, paired values are reproduced in the same order as supplied in the source data.
AMK-T – Technical Data for Typical Constructions
| Technical Data | 2×16 | 4×16 | 4×25 | 4×35 | 4×50 | 4×70 | 4×95 | 4×120 | 4×150 |
|---|---|---|---|---|---|---|---|---|---|
| Conductor diameter, approx. (mm) | 4.7 | 4.7 | 6.1 | 6.8 | 8.2 | 9.6 | 11.9 | 12.7 | 14.1 |
| Insulated conductor diameter, approx. (mm) | 6.7 | 6.7 | 8.1 | 8.8 | 10.6 | 12.4 | 14.6 | 15.9 | 17.7 |
| Overall cable diameter, approx. (mm) | 15 | 18 | 21 | 23 | 27 | 31 | 37 | 40 | 44 |
| Complete cable weight, approx. (kg/km) | 125 | 250 | 380 | 480 | 675 | 945 | 1,300 | 1,650 | 2,050 |
| Minimum breaking load of single core (kN) | 2.6 | 2.6 | 4.2 | 5.6 | 7.4 | 10.3 | 14.0 | 17.6 | 22.0 |
| Minimum breaking load of complete cable (kN) | 5.2 | 10.4 | 16.8 | 22.4 | 29.6 | 41.2 | 56.0 | 70.4 | 88.0 |
| Conductor DC resistance at +20°C (Ω/km) | 1.91 | 1.91 | 1.20 | 0.868 | 0.641 | 0.443 | 0.320 | 0.253 | 0.206 |
| Thermal short-circuit current capacity for 1 s (kA) | 1.1 | 1.1 | 1.8 | 2.5 | 3.6 | 5.0 | 6.8 | 8.5 | 10.7 |
AMK-X – Technical Data for Typical Constructions
| Technical Data | 2×16 | 4×16 | 4×25 | 4×35 | 4×50 | 4×70 | 4×95 | 4×120 | 4×150 |
|---|---|---|---|---|---|---|---|---|---|
| Conductor diameter, approx. (mm) | 4.7 | 4.7 | 6.1 | 6.8 | 8.2 | 9.6 | 11.9 | 12.7 | 14.1 |
| Insulated conductor diameter, approx. (mm) | 7.3 | 7.3 | 8.7 | 9.4 | 11.2 | 12.6 | 15.3 | 16.1 | 17.5 |
| Overall cable diameter, approx. (mm) | 16 | 19 | 22 | 24 | 28 | 32 | 38 | 40 | 44 |
| Complete cable weight, approx. (kg/km) | 140 | 275 | 405 | 510 | 715 | 960 | 1,350 | 1,650 | 2,000 |
| Minimum breaking load of single core (kN) | 2.6 | 2.6 | 4.2 | 5.6 | 7.4 | 10.3 | 14.0 | 17.6 | 22.0 |
| Minimum breaking load of complete cable (kN) | 5.2 | 10.4 | 16.8 | 22.4 | 29.6 | 41.2 | 56.0 | 70.4 | 88.0 |
| Conductor DC resistance at +20°C (Ω/km) | 1.91 | 1.91 | 1.20 | 0.868 | 0.641 | 0.443 | 0.320 | 0.253 | 0.206 |
| Thermal short-circuit current capacity for 1 s (kA) | 1.1 | 1.1 | 1.8 | 2.5 | 3.6 | 5.0 | 6.8 | 8.5 | 10.7 |
Manufacturing and Customization
AMKA aerial bundled cables can be specified according to project requirements, including:
- Aluminium conductor cross-sectional area
- Number of phase conductors
- Optional street-lighting conductors
- PE, HDPE or XLPE insulation, according to the selected design
- Bare or insulated messenger conductor, where applicable
- Cable dimensions and technical requirements
For project enquiries, please provide the required cable type, conductor configuration, applicable standard and quantity for technical evaluation and quotation.
Frequently Asked Questions About AMKA Aerial Bundled Cable
1. What is AMKA aerial bundled cable?
AMKA is a low-voltage aerial bundled cable designed for overhead power distribution. It uses aluminium phase conductors with weather-resistant insulation and a supporting messenger conductor.
2. What is the difference between AMKA, AMKA-T and AMKA-X?
The AMKA construction uses insulated conductors laid around a messenger and PE insulation. AMKA-T uses HDPE insulation, while AMKA-X uses XLPE insulation. The AMKA-T and AMKA-X designs also provide options for additional street-lighting conductors and different messenger constructions.
3. What is the difference between AMK-T and AMK-X?
AMK-T uses black, weather-resistant HDPE insulation, while AMK-X uses black, weather-resistant XLPE insulation. Both are twisted aerial cable constructions with aluminium conductors.
4. What conductor material is used in AMKA cable?
The phase conductors are aluminium. Depending on the selected design and cross-sectional area, they may be solid or stranded and compacted. Messenger conductors in AMKA-T and AMKA-X can be aluminium alloy in bare or insulated construction.
5. What insulation materials are available?
The product information includes PE, HDPE and XLPE insulation. The exact material depends on the cable series and construction.
6. Can AMKA cable include street-lighting conductors?
Yes. AMKA-T and AMKA-X designs can include up to two optional insulated street-lighting conductors, depending on the selected configuration.
7. What is the maximum operating temperature of AMKA cable?
The supplied AMKA product data specifies a maximum operating temperature of 70°C. Separate operating-temperature ratings for AMKA-T, AMKA-X, AMK-T and AMK-X are not stated in the supplied technical information.
8. What is the maximum short-circuit temperature of AMKA cable?
The AMKA product description specifies a maximum short-circuit temperature of 135°C for 5 seconds. The technical tables for the other cable series provide short-circuit current capacity for 1 second.
9. Which standards are listed for AMKA aerial bundled cable?
The supplied documentation lists SFS 2200, HD 626 S1 and IEC 60228. The applicable standards should be confirmed against the required cable construction and project specification.
10. What sizes are available?
The supplied technical tables include AMKA configurations from 1×16+25 to 3×120+95, AMKA-T and AMKA-X configurations from 1×16+16 to 3×150+70, and AMK-T and AMK-X configurations from 2×16 to 4×150.
11. Can AMKA cable be customized?
Cable configurations can be evaluated according to project requirements, including conductor size, number of phase conductors, optional lighting conductors, insulation material and messenger construction. Technical specifications or project drawings can be submitted for review.
Certificate Display
Type and routine tests are issued from our own testing centre under the ISO 9001 quality system — test reports and certificates accompany every shipment.
Factory Tour
Why Choose Us
Packing & Shipping
- Wooden, steel or steel-wood drums; drum length to customer requirement
- Drum marking per customer / utility specification
- Both drum ends sealed and protected for sea freight
Ready for Your Next Cable Project?
Send us your specifications, cable schedule or RFQ — our engineering team replies with a technical proposal and price within one working day.
- Emailinfo@qzcablegroup.com
- WhatsApp / WeChat+86 173 3570 4553
- Contact personChloe · Export Department
- Factory addressWest Industrial Park, Zhulin Town, Gongyi City, Henan Province, China
Related products
High Conductivity Aluminium Alloy Conductor (AAAC) – AL5, AL6, AL7, AL57, AL59 & Alloy 1120
high conductivity aluminium alloy conductor, AAAC conductor, AAAC manufacturer, AL5 conductor, AL6 conductor, AL7 conductor, AL57 conductor, AL59 conductor, Alloy 1120 conductor, high conductivity AAAC, aluminium alloy overhead conductor, overhead transmission conductor, BS EN 50182
AAAC AL7 Conductor – All Aluminium Alloy Conductor
AAAC conductor, AAAC AL7, AL7 conductor, AL7 aluminium alloy conductor, all aluminium alloy conductor, aluminium alloy overhead conductor, AAAC conductor manufacturer, EN 50182 conductor, overhead transmission conductor, overhead distribution conductor
AAAC (AL59) Conductor – High-Strength Aluminium Alloy Conductor
AAAC conductor, AAAC AL59, AL59 conductor, aluminum alloy conductor, all aluminium alloy conductor, AAAC conductor manufacturer, SS 424 08 14, SS EN 50182, overhead alloy conductor, stranded aluminum alloy conductor, grease filled AAAC conductor
AAC (AL1) – All Aluminium Conductor
AAC conductor, AAC conductor manufacturer, all aluminium conductor, AL1 conductor, AAC overhead conductor, bare aluminium conductor, aluminium stranded conductor, SS EN 50182, overhead distribution conductor, aluminium power conductor
AAAC — Aluminum Alloy Conductor
AAAC conductor, AAAC conductor manufacturer, all aluminum alloy conductor, AAAC cable, ASTM B399 AAAC, aluminum alloy overhead conductor, overhead transmission conductor, overhead distribution conductor, AAAC 6201, bare overhead conductor
AAC — All Aluminum Conductor
AAC conductor, AAC conductor manufacturer, all aluminium conductor, all aluminum conductor, AAC cable, aluminum stranded conductor, aluminium stranded conductor, Aluminum 1350-H19 conductor, ASTM B230, ASTM B231, AS/NZS 1531, DIN 48201 Part 5, GOST 839-80, BS 215-1, BS EN 50182, IEC 61089, bare overhead conductor, overhead distribution conductor.
ACSR — Aluminum Conductor Steel Reinforced
ACSR conductor, ACSR conductor manufacturer, ACSR cable, ACSR/AW conductor, ACSR/TW conductor, aluminum conductor steel reinforced, aluminum clad steel reinforced conductor, trapezoidal wire ACSR, overhead transmission conductor, bare overhead conductor, ASTM B232, ASTM B549, ASTM B779, IEC 61089.
ACAR — Aluminum Conductor, Aluminum-Alloy Reinforced
ACAR conductor, ACAR conductor manufacturer, aluminum alloy reinforced conductor, aluminum conductor alloy reinforced, 1350/6201 conductor, ASTM B524 ACAR, overhead ACAR conductor, bare overhead conductor, overhead transmission conductor, aluminum alloy conductor
AACSR — Aluminum Alloy Conductor Steel Reinforced
AACSR conductor, AACSR conductor manufacturer, AACSR cable, AACSR/AW conductor, aluminum alloy conductor steel reinforced, aluminum alloy overhead conductor, aluminum clad steel reinforced conductor, 6201 aluminum alloy conductor, IEC 61089 conductor, ASTM B711 conductor, AS 3607 conductor, long span overhead conductor, high strength transmission conductor.
LV ABC Cable – Low Voltage Aerial Bundled Cable
LV ABC cable, low voltage aerial bundled cable, ABC cable manufacturer, overhead bundled conductor, Duplex ABC cable, Triplex ABC cable, Quadruplex ABC cable, 600V aerial cable, HDPE insulated cable
ALUS-D (ABC-D) 1 kV – Halogen-Free Aluminium Aerial Bundled Cable
ALUS-D 1 kV Cable, ABC-D Aerial Bundled Cable, Halogen-Free Aerial Cable, Aluminium Aerial Bundled Cable, 1 kV Aluminium Cable, PE Insulated Aerial Cable, UV-Resistant Aluminium Cable, Class 2 Aluminium Conductor Cable, Low Voltage Aerial Cable, Aerial Service Connection Cable, ABC Downlead Cable
CCST (BLL) Covered Conductor – 10–52 kV | EN 50397-1
PE Insulated Covered Conductor, HDPE Sheathed Overhead Conductor, Longitudinally Water-Blocked Conductor, Medium Voltage Covered Conductor, AAAC Covered Conductor, ACSR Covered Conductor, ACSC Covered Conductor, EN 50397-1 Covered Conductor, Water-Blocked Overhead Cable
CCSX-Hybrid Covered Conductor – XLPE Insulation & HDPE Sheath
CCSX Hybrid, CCSX Hybrid cable, CCSX covered conductor, XLPE covered conductor, HDPE covered conductor, water blocked overhead conductor, AAAC covered conductor, ACSR covered conductor, EN 50397-1
CCSX (BLX) Covered Overhead Line Conductor – 10–52 kV
CCSX cable, BLX covered conductor, CCSX conductor manufacturer, 10–52 kV covered conductor, water-blocked overhead conductor, EN 50397-1 cable, Al7 conductor, FeAl conductor
SAC Spaced Aerial Cable Manufacturer – AAC Spacer Cable | ICEA S-66-524
SAC cable, spaced aerial cable, SAC cable manufacturer, spacer cable, AAC spacer cable, overhead spacer cable, 15kV SAC cable, 25kV SAC cable, 35kV SAC cable, XLPE XLPE cable, XLPE HDPE cable, ICEA S-66-524
Cable Semiaislado o Ecológico – Medium Voltage Covered Overhead Conductor
Cable Semiaislado o Ecológico, Cable Semiaislado, Cable Ecológico Media Tensión, Conductor Cubierto de Media Tensión, Cable Cubierto para Redes Aéreas, Medium Voltage Covered Conductor, Anti-Tracking Overhead Conductor, AAC AAAC ACSR Covered Conductor
PVC-Covered Aluminium Conductors – AAC & ACSR
PVC covered aluminium conductor, PVC covered conductor, PVC covered overhead wire, PVC covered AAC conductor, PVC covered ACSR conductor, PVC insulated aluminium conductor, stranded aluminium overhead conductor, PVC covered power line conductor, BS 6485 conductor, BS 215 conductor
XS/LXS Overhead Aerial Bundle Cable – Copper & Aluminum Conductors
XS cable, LXS cable, XS LXS cable, aerial bundle cable, overhead aerial bundle cable, copper aerial cable, aluminum aerial cable, copper ABC cable, aluminum ABC cable, 0.6/1kV overhead cable, DMA C33-209 cable, XLPE aerial cable, low voltage overhead distribution cable
TYIR / TYIR 50 OL-AL PVC Bundled Overhead Line Cable
TYIR cable, TYIR 50 OL-AL cable, PVC bundled overhead cable, PVC aerial cable, aluminium overhead cable, low voltage aerial cable, 0.6/1 kV overhead cable, steel aluminium supporting neutral conductor
T2X — Bundle Assembled Aerial Cables XLPE-insulated
T2X cable, T2X aerial cable, XLPE bundled aerial cable, XLPE overhead cable, 0.6/1 kV aerial cable, aluminium aerial cable, steel-aluminium neutral conductor, TIX 2 cable
NF2X / NFA2X Aerial Bundled Cable – Copper & Aluminium Conductors
NF2X cable, NFA2X cable, NF2X aerial cable, NFA2X aerial bundled cable, copper aerial bundled cable, aluminium ABC cable, XLPE overhead cable, low voltage aerial cable, HD 626 cable, VDE 0276-626
600V Covered Overhead Line Wire – AAC, AAAC & ACSR
600V covered conductor, covered overhead line wire, covered line wire manufacturer, AAC covered conductor, AAAC covered conductor, ACSR covered conductor, aluminium covered conductor, LDPE covered conductor, HDPE covered conductor, XLPE covered conductor, overhead secondary distribution wire
E-A2Y 0.6/1 kV PE-Insulated Self-Supporting Aerial Cable
E-A2Y cable, E-A2Y 0.6/1 kV, PE insulated aerial cable, polyethylene insulated overhead cable, self-supporting aerial cable, aluminium aerial cable, low voltage overhead cable, OVE E 8200-626
AER Cable – 0.6/1kV PE insulated aerial power cables with aluminium conductor
AER cable, aerial bundled cable, AER aerial cable, low voltage ABC cable, 0.6/1 kV aerial cable, aluminium aerial cable, SFS 2200 cable, HD 626 S1 cable, rural electrification cable
16mm2 Twin Conductor Wire AAC PVC Parallel Aluminum Cable
16mm2 Twin Conductor Wire AAC PVC Parallel Aluminum Cable
Related solutions
Power Generation Cable Solutions
QZ Cable supplies power generation cable solutions for thermal, hydro, solar and wind power projects, including LV/MV power cables, control cables, instrumentation cables and overhead conductors.
Power Transmission Cable Solutions
QZ Cable supplies power transmission solutions, including AAC, AAAC, ACSR, ACSS, TACSR, TAAAC, OPGW and ADSS for utility, grid expansion and EPC projects worldwide.
Power Distribution Cable Solutions
Qingzhou Cable provides low- and medium-voltage cable solutions for electrical distribution networks, supporting power delivery from substations to commercial, industrial and residential users.
Power Substation Cable Solutions
Solar & Renewable Energy Cable Solutions