One-stop Solution for Wire & Cable · Since 1969
GSW — Galvanized Steel Wire/Strand
Bare Conductors

GSW — Galvanized Steel Wire/Strand

galvanized steel wire strand, galvanized steel strand manufacturer, ASTM A475 steel strand, galvanized guy wire, overhead ground wire strand, galvanized steel guy strand, power transmission line strand, galvanized steel wire rope strand, Class A galvanized strand, Class B galvanized strand, Class C galvanized strand

  • Hot-Dip Galvanized Steel Wire | High Tensile Strength
  • Excellent Corrosion Resistance | Durable Performance
  • Overhead Power Lines | Grounding & Earthing Systems
  • Direct Factory Supply | Bulk Orders Welcome | MOQ: 10KM
  • Custom Diameters & Specifications Available
  • Galvanized Steel Wire Strand Manufacturer | QZ Cable

Product Description

Application

The galvanized steel wire also named Guy Wire, Earth wire with Galvanised Steel Wire (GSW) or Aluminium Clad steel (ACS) & Stay Wire. Strand is used for overhead ground lines or electrical power transmission lines. Stay or guy wire strands are produced for use with poles, towers, or any other form of guying.

The galvanized single steel wires or stranded steel wires are suitable for cores of ACSR to improve its tensile strength. And they can also be used in the aerial transmission line as the line material of ground connection to avoid the lightning strike.

Bare concentric-lay-stranded conductors are made from bare, hard-drawn, round, aluminum clad steel wires for general use of electrical purposes. Tensile strength and zinc-clad of steel wire have different grades.

  • Pole and tower support systems
  • Overhead line guying and anchoring
  • Grounding and earthing networks
  • Shielding earth wires for transmission lines
  • Infrastructure requiring mechanical stability and structural reinforcement

Standard

Specification
● IEC 61089 Round Wire Concentric Lay Overhead Electrical Stranded Conductors
● ASTM A 475 Zinc-Coated Steel Wire Strand
● BS 183 General Purpose Galvanized Steel Wire Strand
● AS 1222.1 Steel Conductors and Stays—Bare overhead Part 1: Galvanized (SC/GZ)
● GB/T 1179 Round Wire Concentric Lay Overhead Electrical Stranded Conductors

Construction

Concentrically stranded Galvanized steel wire strand available in class “A”, “B” and “C” galvanizing, “A” being the least heavy and “C” being the most heavy. Manufactured without welds per ASTM A-363 or with welds per ASTM A-475. Strands are formed to remain substantially in place when severed.

Construction Parameters

ASTM A 475

Nominal diameter of strandNumber of Wires in StrandNominal Diameter of Coated Wire in StrandApprox.
weight of strand
Minimun Breaking Strength of Strand
Utilities GradeCommon GradeSiemens-
Martin Grade
High-
Strength Grade
Extra-high Strength Grade
In.mm mmkg/kmkNkNkNkNkN
1/83.1871.0448–2.4024.0485.9168.140
5/323.9771.3276–3.8706.5399.51913.078
3/164.7671.57109–5.1158.45212.67717.748
3/164.7671.6511910.676––––
7/325.5632.64131–6.22810.40915.56921.796
7/325.5671.83146–6.85011.38717.12624.020
1/46.3533.0517414.0128.27413.52321.04029.981
1/46.3533.0517420.017––––
1/46.3572.03180–8.45214.01221.12929.581
9/327.1433.30204–9.25215.03523.39833.362
9/327.1472.3624420.46211.43218.90528.46939.812
5/167.9433.6825528.91311.07618.19328.24640.479
5/167.9472.64305–14.23423.79835.58649.820
5/167.9472.7733526.689––––
3/89.5234.1932837.81014.81324.73237.18752.489
3/89.5273.0540751.15518.90530.91548.04068.503
7/1611.1173.6859580.06825.35541.59164.49992.523
1/212.7074.19770111.20632.91753.82383.627119.657
1/212.70192.54751–33.89556.49284.961118.768
9/1614.2974.781000–42.70369.837108.981155.688
9/1614.29192.87949–42.88171.616107.202149.905
5/815.8875.261211–51.59984.961131.667188.605
5/815.88193.181186–48.93080.513124.995178.819
3/419.05193.811721–71.172116.543181.487259.331
7/822.22194.502356–97.416159.691248.211354.523
125.40195.083089–127.664209.066325.610464.839
125.40373.633065–125.885205.508319.827456.832
1 1/828.58374.094010–160.136262.000407.457581.827
1 1/431.75374.554840–198.391324.720505.318721.502

Note:Class A and Class B and Class C are in same structure.

BS 183

Construction Number of wires/wire diameterApproximate strand diameterMinimum breaking load of strandApprox.
mass
Grade 350Grade 480Grade 700Grade 850Grade 1000Grade 1150Grade 1300
mmkNkNkNkNkNkNkNkg/1000 m
3/1.803.92.653.66—————60
3/2.655.75.87.95—————130
3/3.2578.711.95—————195
3/4.008.613.218.1—————295
4/1.804.43.554.9—————80
4/2.656.47.710.6—————172
4/3.257.911.615.9—————260
4/4.009.717.624.135.2————390
5/1.504.13.14.246.18————69
5/1.804.94.456.18.9————95
5/2.657.29.6513.2519.3————220
5/3.258.814.519.929————320
5/4.0010.82230.1543.95————490
7/0.561.70.60.831.2—1.71.982.2414
7/0.712.10.971.331.94—2.753.193.628
7/0.852.61.391.92.8—3.954.575.1531
7/0.902.71.552.143.1—4.455.125.835
7/1.0031.922.643.85—5.56.327.1543
7/1.253.83.014.16—8.559.8811.1567
7/1.404.23.755.177.549.1610.7512.351484
7/RSa4.33.855.287.79.351112.6514.386
7/1.604.84.96.759.8511.9514.116.218.3110
7/1.805.46.238.5512.45—17.820.523.2140
7/2.0067.710.5515.4—2225.328.6170
7/2.367.110.714.721.4—30.635.239.8240
7/2.65813.518.527—38.644.450.2300
7/3.00917.323.7534.65—49.556.964.3392
7/3.159.519.126.238.2—54.5562.7570.9430
7/3.259.820.327.8540.65—58.0566.875.5460
7/3.651125.635.1551.25—73.2584.295.2570
7/4.001230.942.261.6—88101114690
7/4.2512.834.7547.6569.5—99.3114129780
7/4.751443.459.4586.8—124142.7161.3970
19/1.0055.227.1610.45—14.9217.1619.4120
Construction Number of wires/wire diameterApproximate strand diameterMinimum breaking load of strandApprox.
mass
Grade 350Grade 480Grade 700Grade 850Grade 1000Grade 1150Grade 1300
mmkNkNkNkNkNkNkNkg/1000 m
19/1.256.38.1611.1916.32—23.3226.8130.31180
19/1.40710.2414.0420.47—29.2533.6438.02230
19/1.60813.3718.3426.75—38.243.9349.66300
19/2.001020.928.6541.7850.7459.6968.6477.6470
19/2.5012.532.6544.865.2979.2893.27107.3121.3730
19/3.00154764.594114.1134.3154.5174.61050
19/3.5517.865.890.27131.6159.9188216.3244.51470
19/4.002083.55114.6167.1203238.7274.6310.41870
19/4.7523.8117.85161.6235.7286336.7387.2437.72630
The construction of this strand consists of six wires of 1.40 mm diameter on a centre wire of 1.50 mm diameter. The diameter of the centre wire shall not be less than 0.08 mm nor more than 0.12 mm greater than the diameter of the outer wire.

AS 1222.1

Standing and wire diameterApprox. overall diameterCross-section areaApprox. mass per kmCalculated breaking load (CBL)Equivalent aluminium areaTypical d.c. resistance per km at 20°C
mmmmmm²kgkNmm²Ω
3/2.004.319.4267411.71.420
3/2.755.9317.8214022.22.611
7/2.00621.99173263.28.7
7/2.758.2541.58328496.14.6
7/3.259.7558.0745868.78.63.3
7/3.7511.377.2860991.3112.5
19/2.001059.747370.58.83.2
19/2.7513.8112.9894133171.7
19/3.2516.3157.61250186231.2

IEC 60189

Code No.Section AreaNo./Dia of WireApprox. Overall DiameterApprox. WeightBreaking LoadDC Resistance at 20°C Max.
S1AS1BS2AS3A
 mm²No./mmmmkg/kmkNkNkNkNOhm/km
427.17/2.226.66213.336.333.639.343.97.1445
6.342.77/2.798.36335.955.951.760.267.94.5362
1067.87/3.5110.53553.287.480.793.5103.02.8578
12.584.77/3.9311.78666.5109.3100.8116.9128.82.2862
16108.47/4.4413.32853.1139.9129.0199.7164.81.7861
16108.419/2.7013.48857.0142.1131.2152.9172.41.7944
25169.419/3.3716.851339.1218.6201.6238.9262.61.1484
40271.119/4.2621.312141.6349.7322.6374.1412.10.7177
40271.137/3.0521.382148.1349.7322.6382.3420.20.7196
63427.037/3.8326.833383.2550.8508.1589.3649.00.4569

Certificate Display

ISO 9001 Quality Management System
ISO 9001 Certificate (2025–2028)
ISO 9001 Certificate (NOA)
CE — Verification of Conformity
RoHS Compliance Attestation (EU)
Low Voltage Directive Attestation (EU)

Type and routine tests are issued from our own testing centre under the ISO 9001 quality system — test reports and certificates accompany every shipment.

Factory Tour

Why Choose Us

50+ years of experience Trusted manufacturing expertise since 1969
International standards IEC, ASTM, BS, CSA and other global standards
Strict quality control Comprehensive testing throughout production
Large production capacity Reliable supply for utility and EPC projects
Fast global delivery Efficient manufacturing and worldwide shipping
Technical support Expert assistance from inquiry to project completion

Packing & Shipping

  • Wooden, steel or steel-wood drums; drum length to customer requirement
  • Drum marking per customer / utility specification
  • Both drum ends sealed and protected for sea freight
Get in touch

Ready for Your Next Cable Project?

Send us your specifications, cable schedule or RFQ — our engineering team replies with a technical proposal and price within one working day.

  • Emailinfo@qzcablegroup.com
  • WhatsApp / WeChat+86 173 3570 4553
  • Contact personChloe · Export Department
  • Factory addressWest Industrial Park, Zhulin Town, Gongyi City, Henan Province, China

    The more specific the standard and size, the faster we can quote.

    Related products

    ACSR — Aluminum Conductor Steel Reinforced ACSR conductor, ACSR conductor manufacturer, ACSR cable, ACSR/AW conductor, ACSR/TW conductor, aluminum conductor steel reinforced, aluminum clad steel reinforced conductor, trapezoidal wire ACSR, overhead transmission conductor, bare overhead conductor, ASTM B232, ASTM B549, ASTM B779, IEC 61089. ACSS — Aluminum Conductor Steel Supported/Trapezoidal Wire ACSS conductor, ACSS conductor manufacturer, ACSS/AW conductor, ACSS/TW conductor, aluminum conductor steel supported, high temperature overhead conductor, 250°C conductor, high ampacity conductor, overhead transmission conductor, transmission line reconductoring, low sag conductor, annealed aluminum conductor ACS — Aluminum Clad Steel Wire Aluminum-clad steel wire, aluminum clad steel wire manufacturer, ACS wire, ACS conductor, AW wire, AS wire, AC wire, aluminum-clad steel, aluminum clad steel core wire, ASTM B502, ASTM B415, IEC 61232, ACSR/AW conductor, OPGW wire, overhead ground wire, aluminum-clad steel strand. AACSR — Aluminum Alloy Conductor Steel Reinforced AACSR conductor, AACSR conductor manufacturer, AACSR cable, AACSR/AW conductor, aluminum alloy conductor steel reinforced, aluminum alloy overhead conductor, aluminum clad steel reinforced conductor, 6201 aluminum alloy conductor, IEC 61089 conductor, ASTM B711 conductor, AS 3607 conductor, long span overhead conductor, high strength transmission conductor. AAC — All Aluminum Conductor AAC conductor, AAC conductor manufacturer, all aluminium conductor, all aluminum conductor, AAC cable, aluminum stranded conductor, aluminium stranded conductor, Aluminum 1350-H19 conductor, ASTM B230, ASTM B231, AS/NZS 1531, DIN 48201 Part 5, GOST 839-80, BS 215-1, BS EN 50182, IEC 61089, bare overhead conductor, overhead distribution conductor. AAAC — Aluminum Alloy Conductor AAAC conductor, AAAC conductor manufacturer, all aluminum alloy conductor, AAAC cable, ASTM B399 AAAC, aluminum alloy overhead conductor, overhead transmission conductor, overhead distribution conductor, AAAC 6201, bare overhead conductor Bare Copper & Tinned Conductor HDBC Conductor, stranded bare copper conductor, tinned copper conductor, bare copper stranded wire, stranded tinned copper wire, bare copper conductor manufacturer, tinned copper wire manufacturer, copper grounding conductor, copper earthing conductor, concentric lay stranded copper, soft drawn copper conductor, tin coated copper wire CCS — Copper Clad Steel Conductor copper clad steel wire, CCS wire manufacturer, copper coated steel wire, copper clad steel grounding wire, CCS grounding conductor, copper clad steel wire for lightning protection, 30% conductivity CCS, 40% conductivity CCS, railway grounding wire, telecom grounding wire, ASTM B227, ASTM B228 GAP — Gap Type Aluminum Conductor Steel Reinforced Gap Conductor GAP conductor, GAP conductor manufacturer, gap type aluminum conductor steel reinforced, gap type ACSR conductor, gap conductor for overhead transmission lines, high temperature overhead conductor, low sag conductor, transmission line uprating, reinforced aluminum conductor, overhead power line conductor STACIR — Steel Reinforced Aluminum Conductor Invar Reinforced Trapezoidal Wire STACIR conductor, STACIR/AW conductor, STACIR conductor manufacturer, super thermal alloy conductor, INVAR reinforced conductor, high temperature overhead conductor, 210°C conductor, transmission line uprating, reconductoring conductor, aluminum-clad INVAR core, overhead transmission conductor KTACSR — K-Thermal Resistant Aluminum Alloy Conductor Steel Reinforced TAL conductors, KTACSR conductor, KTACSR/AW conductor, KTACSR conductor manufacturer, high strength heat resistant conductor, thermal resistant aluminum alloy conductor, steel reinforced aluminum conductor, AT2 aluminum alloy conductor, high temperature overhead conductor, overhead transmission conductor, transmission line capacity upgrade, large span overhead conductor TACSR & TACSR/AW — Thermal-Resistant Aluminum Conductor Steel Reinforced TACSR conductor, TACSR conductor manufacturer, thermal resistant aluminum conductor, high temperature conductor, steel reinforced aluminum conductor, overhead transmission conductor, TAL conductor, transmission line capacity upgrade, overhead power line conductor, TACSR/AW conductor High Temperature Thermal Resistant Alloy conductors TACIR and ZTACIR INVAR conductor, INVAR conductor manufacturer, aluminum-clad invar conductor, thermal-resistant aluminum alloy conductor, high-temperature overhead conductor, low sag conductor, overhead transmission conductor, transmission line reconductoring, IEC 62004 conductor TAAAC — Thermal-Resistant All Aluminum Alloy Conductor TAAAC - The full name: Thermal Resistant Aluminum-alloy Conductors. Urban network capacity transformation, substation, power plant construction and general lines ACAR — Aluminum Conductor, Aluminum-Alloy Reinforced ACAR conductor, ACAR conductor manufacturer, aluminum alloy reinforced conductor, aluminum conductor alloy reinforced, 1350/6201 conductor, ASTM B524 ACAR, overhead ACAR conductor, bare overhead conductor, overhead transmission conductor, aluminum alloy conductor
    Inquiry WhatsApp Email