MV ABC Wire – SANS 1713
SANS 1713 MV ABC Cable, MV ABC Cable, Medium Voltage Aerial Bundled Cable, 11kV Aerial Bundled Cable, 22kV MV ABC Cable, 33kV MV ABC Cable, Armoured MV ABC Cable, Unarmoured MV ABC Cable, SANS 1713 Cable
- Medium Voltage Aerial Bundled Cable (MV ABC) – South African Standard
- 3.8/6.6 kV to 19/33 kV Aluminium Conductor | XLPE Insulation
- Copper Screen | PE / PVC Outer Serving Steel Catenary Supported Design
- Designed for Overhead Power Distribution
Product Description
MV ABC (Medium Voltage Aerial Bundled Cable) is designed for overhead installation in public medium-voltage power distribution networks. Manufactured in accordance with SANS 1713, the cable is suitable for distribution systems ranging from 3.8/6.6 kV to 19/33 kV.
The cable consists of three stranded hard-drawn aluminium phase conductors, individually insulated with triple-layer TR-XLPE insulation, and assembled with a supporting catenary conductor. Depending on the required design, the cable can be supplied in armoured or unarmoured configurations.
MV ABC cables provide a practical solution for overhead medium-voltage distribution, combining electrical insulation, mechanical support and outdoor durability for utility and infrastructure projects.
Applications
- Medium-voltage overhead power distribution networks
- Public electricity distribution systems
- Utility overhead line installations
- Rural and urban distribution networks
- Infrastructure and electrification projects
- Overhead power lines requiring supported bundled cable construction
Applicable Standard
SANS 1713
Electric cables – Medium voltage aerial bundled conductors for voltages from 3.8/6.6 kV to 19/33 kV.
Product Types
Type A – Armoured MV ABC
- Armoured medium-voltage aerial bundled cable.
- Available for 3.8/6.6 kV, 6.35/11 kV, 12.7/22 kV and 19/33 kV applications.
- Phase conductor sizes: 95–185 mm², according to the source specification.
Type B – Unarmoured MV ABC
- Unarmoured medium-voltage aerial bundled cable.
- Available for 3.8/6.6 kV, 6.35/11 kV and 12.7/22 kV applications.
- Phase conductor sizes: 35–185 mm².
- For 19/33 kV applications, phase conductor sizes: 50–185 mm².
Cable Construction

1. Conductor
Stranded, circular and compacted hard-drawn aluminium conductors, Class 2.
2. Conductor Screening
Extruded thermosetting semi-conductive layer applied over the aluminium conductor.
3. Insulation
Triple-layer TR-XLPE thermosetting insulation system, designed for medium-voltage overhead applications.
4. Insulation Screening
Extruded thermosetting semi-conductive layer applied over the insulation, with a swellable semi-conducting tape incorporated for water-tightness.
5. Metallic Screen
Plain soft copper wires and/or copper tape applied helically, or longitudinally bonded aluminium tape, depending on the specified construction.
6. Outer Sheath
Extruded black polyethylene (PE) sheath. PVC sheath is available upon specific customer requirements.
7. Steel Messenger / Catenary
50 mm² or 70 mm² galvanized steel stranded wires, covered with black PE. PVC covering is available upon specific customer requirements.
MV ABC Cable Voltage Range
| Voltage Rating | Typical Application |
|---|---|
| 3.8/6.6 kV | Medium-voltage overhead distribution |
| 6.35/11 kV | 11 kV overhead distribution networks |
| 12.7/22 kV | 22 kV overhead distribution networks |
| 19/33 kV | 33 kV overhead distribution networks |
Cable Size Range
| Cable Type | Voltage Rating | Phase Conductor Size |
|---|---|---|
| Type A – Armoured | 3.8/6.6 kV | 95–185 mm² |
| Type A – Armoured | 6.35/11 kV | 95–185 mm² |
| Type A – Armoured | 12.7/22 kV | 95–185 mm² |
| Type A – Armoured | 19/33 kV | 95–185 mm² |
| Type B – Unarmoured | 3.8/6.6 kV | 35–185 mm² |
| Type B – Unarmoured | 6.35/11 kV | 35–185 mm² |
| Type B – Unarmoured | 12.7/22 kV | 35–185 mm² |
| Type B – Unarmoured | 19/33 kV | 50–185 mm² |
Other cable configurations are available according to project requirements.
Technical Specifications
6.6 kV MV ABC Cable
| Phase Core | ||||||||
| Conductor size | mm2 nom | 35 | 50 | 70 | 95 | 120 | 150 | 185 |
| Conductor diameter | mm app. | 7.15 | 8.25 | 9.95 | 11.8 | 13.1 | 14.8 | 15.95 |
| Insulation diameter | mm app. | 15.4 | 16.5 | 18.2 | 20.1 | 21.4 | 22.7 | 24.2 |
| Core sheath diameter | mm app. | 20.5 | 21.6 | 23.5 | 25.5 | 26.8 | 28.1 | 29.9 |
| Catenary (Support Core) | ||||||||
| Conductor size | mm2 nom | 50 | 50 | 50 | 50 | 70 | 70 | 70 |
| Conductor diameter | mm app. | 9 | 9 | 9 | 9 | 10.8 | 10.8 | 10.8 |
| Insulation diameter | mm app. | 11.5 | 11.5 | 11.5 | 11.5 | 13.3 | 13.3 | 13.3 |
| Maximum tensile strength and pulling force of catenary | kN | 26 | 26 | 26 | 26 | 37 | 37 | 37 |
| Cable | ||||||||
| Cable diameter | mm app. | 44 | 47 | 51 | 55 | 58 | 61 | 65 |
| Cable mass | kg/m app. | 2.05 | 2.24 | 2.6 | 3.01 | 3.51 | 3.85 | 4.33 |
| Gross mass (500m) | kg app. | 915 | 973 | 1,079 | 1,204 | 1,354 | 1,454 | 1,599 |
| Bending radius | mm min. | 636 | 669 | 720 | 776 | 841 | 880 | 926 |
| Current rating | ||||||||
| In air | Amps | 150 | 185 | 230 | 280 | 325 | 370 | 430 |
| Resistance | ||||||||
| dc @ 20°C | W/km max | 0.868 | 0.641 | 0.443 | 0.32 | 0.253 | 0.206 | 0.164 |
| ac @ 90°C | W /km max | 1.113 | 0.822 | 0.568 | 0.411 | 0.325 | 0.265 | 0.211 |
| Reactance | W /km | 0.136 | 0.124 | 0.121 | 0.114 | 0.111 | 0.106 | 0.103 |
| Impedance | W /km | 1.121 | 0.832 | 0.581 | 0.426 | 0.342 | 0.284 | 0.233 |
| Short circuit ratings | ||||||||
| Symmetrical | kA (1 sec) | 3 | 4 | 5.8 | 8 | 10.2 | 12.5 | 15.7 |
| Earth fault | kA (1 sec) | 1.5 | 1.6 | 1.7 | 1.9 | 2 | 2.1 | 2.3 |
11 kV MV ABC Cable
| 11kv ABC Cable Specification | ||||||||
| Phase Core | ||||||||
| Conductor size | mm2 nom | 35 | 50 | 70 | 95 | 120 | 150 | 185 |
| Conductor diameter | mm app. | 7.15 | 8.25 | 9.95 | 11.8 | 13.1 | 14.8 | 16.35 |
| Insulation diameter | mm app. | 17.3 | 18.4 | 20.1 | 21.9 | 23.2 | 24.5 | 26.1 |
| Core sheath diameter | mm app. | 22.5 | 23.6 | 25.3 | 27.4 | 28.7 | 30.2 | 31.7 |
| Catenary (Support Core) | ||||||||
| Conductor size | mm2 nom | 50 | 50 | 50 | 50 | 70 | 70 | 70 |
| Conductor diameter | mm app. | 9 | 9 | 9 | 9 | 10.8 | 10.8 | 10.8 |
| Insulation diameter | mm app. | 11.5 | 11.5 | 11.5 | 11.5 | 13.3 | 13.3 | 13.3 |
| Maximum tensile strength and pulling force of catenary | kN | 26 | 26 | 26 | 26 | 37 | 37 | 37 |
| Cable | ||||||||
| Cable diameter | mm app. | 49 | 51 | 55 | 59 | 62 | 65 | 69 |
| Cable mass | kg/m app. | 2.31 | 2.52 | 2.85 | 3.28 | 3.61 | 3.99 | 4.43 |
| Gross mass (500m) | kg app. | 993 | 1,055 | 1,155 | 1,285 | 1,382 | 1,496 | 1,628 |
| Bending radius | mm min. | 691 | 724 | 775 | 831 | 896 | 935 | 981 |
| Current rating | ||||||||
| In air | Amps | 150 | 185 | 230 | 280 | 325 | 370 | 430 |
| Resistance | ||||||||
| dc @ 20°C | W/km max | 0.868 | 0.641 | 0.443 | 0.32 | 0.253 | 0.206 | 0.164 |
| ac @ 90°C | W /km max | 1.113 | 0.822 | 0.568 | 0.411 | 0.325 | 0.265 | 0.211 |
| Reactance | W /km | 0.136 | 0.124 | 0.121 | 0.114 | 0.111 | 0.106 | 0.103 |
| Impedance | W /km | 1.121 | 0.832 | 0.581 | 0.426 | 0.342 | 0.284 | 0.233 |
| Short circuit ratings | ||||||||
| Symmetrical | kA (1 sec) | 3 | 4 | 5.8 | 8 | 10.2 | 12.5 | 15.7 |
| Earth fault | kA (1 sec) | 1.5 | 1.6 | 1.7 | 1.9 | 2 | 2.1 | 2.3 |
22 kV MV ABC Cable
| 22kV ABC Cable Specification | ||||||||
| Phase Core | ||||||||
| Conductor size | mm2 nom | 35 | 50 | 70 | 95 | 120 | 150 | 185 |
| Conductor diameter | mm app. | 7.15 | 8.25 | 9.95 | 11.8 | 13.1 | 14.8 | 16.35 |
| Insulation diameter | mm app. | 21.6 | 22.7 | 24.4 | 26.2 | 27.5 | 29.2 | 30.8 |
| Core Sheath diameter | mm app. | 27 | 28.1 | 30 | 31.9 | 33.4 | 35.1 | 36.8 |
| Catenary (Support Core) | ||||||||
| Conductor size | mm2 nom | 50 | 50 | 50 | 50 | 70 | 70 | 70 |
| Conductor diameter | mm app. | 9 | 9 | 9 | 9 | 10.8 | 10.8 | 10.8 |
| Insulation diameter | mm app. | 11.5 | 11.5 | 11.5 | 11.5 | 13.3 | 13.3 | 13.3 |
| Maximum Tensile Strength and Pulling force of Catenary | kN | 26 | 26 | 26 | 26 | 37 | 37 | 37 |
| Cable | ||||||||
| Cable diameter | mm app. | 58 | 61 | 65 | 69 | 72 | 76 | 80 |
| Cable mass | kg/m app. | 2.96 | 3.19 | 3.61 | 4.05 | 4.63 | 5.06 | 5.61 |
| Gross mass (500m) | kg app. | 1 188 | 1 257 | 1 383 | 1 514 | 1 690 | 1 819 | 1 984 |
| Bending radius | mm min. | 821 | 854 | 905 | 960 | 1025 | 1076 | 1123 |
| Current rating | ||||||||
| In air | Amps | 150 | 185 | 230 | 280 | 325 | 370 | 430 |
| Resistance | ||||||||
| dc @ 20°C | W/km max | 0.868 | 0.641 | 0.443 | 0.32 | 0.253 | 0.206 | 0.164 |
| ac @ 90°C | W /km max | 1.113 | 0.822 | 0.568 | 0.411 | 0.325 | 0.265 | 0.211 |
| Reactance | W /km | 0.136 | 0.124 | 0.121 | 0.114 | 0.111 | 0.106 | 0.103 |
| Impedance | W /km | 1.121 | 0.832 | 0.581 | 0.426 | 0.342 | 0.284 | 0.233 |
| Short circuit ratings | ||||||||
| Symmetrical | kA (1sec) | 3 | 4 | 5.8 | 8 | 10.2 | 12.5 | 15.7 |
| Earth fault | kA (1sec) | 1.5 | 1.6 | 1.7 | 1.9 | 2 | 2.1 | 2.3 |
33 kV MV ABC Cable
| 33kV ABC Cable Specification | ||||||||
| Phase Core | ||||||||
| Conductor size | mm2 nom | 50 | 70 | 95 | 120 | 150 | 185 | |
| Conductor diameter | mm app. | 8.25 | 9.95 | 11.8 | 13.1 | 14.8 | 16.35 | |
| Insulation diameter | mm app. | 27.8 | 29.5 | 314 | 32.7 | 34 | 35.5 | |
| Core Sheath diameter | mm app. | 33.7 | 35.4 | 37.4 | 38.7 | 40.2 | 41.8 | |
| Catenary (Support Core) | ||||||||
| Conductor size | mm2 nom | 50 | 50 | 50 | 70 | 70 | 70 | |
| Conductor diameter | mm app. | 9 | 9 | 9 | 10.8 | |10.80 | 10.8 | |
| Insulation diameter | mm app. | 11.5 | 11.5 | 11.5 | 13.3 | 13.3 | 13.3 | |
| Maximum Tensile Strength and Pulling force of Catenary | kN | 26 | 26 | 26 | 37 | 37 | 37 | |
| Cable | ||||||||
| Cable diameter | mm app. | 73 | 76 | 81 | 84 | 87 | 90 | |
| Cable mass | kg/m app. | 4.12 | 4.53 | 5.06 | 5.37 | 5.82 | 6.33 | |
| Gross mass (500m) | kg app. | 1,535 | 1,658 | 1,819 | 1,910 | 2,046 | 2,200 | |
| Bending radius | mm min. | 1007 | 1058 | 1114 | 1179 | |1218 | 1264 | |
| Current rating | ||||||||
| In air | Amps | 185 | 230 | 280 | 325 | 370 | 430 | |
| Resistance | ||||||||
| dc @ 20°C | W/km max | 0.641 | 0.443 | 0.32 | 0.253 | 0.206 | 0.164 | |
| ac @ 90°C | W/km max | 0.822 | 0.568 | 0.411 | 0.325 | 0.265 | 0.211 | |
| Reactance | W /km | 0.124 | 0.121 | 0.114 | 0.111 | 0.106 | 0.103 | |
| Impedance | W /km | 0.832 | 0.581 | 0.426 | 0.342 | 0.284 | 0.233 | |
| Short circuit ratings | ||||||||
| Symmetrical | kA (1 sec) | 4 | 5.8 | 8 | 10.2 | 12.5 | 15.7 | |
| Earth fault | kA (1 sec) | 1.6 | 1.7 | 1.9 | 2 | 2.1 | 2.3 | |
Note: The source table lists 314 mm for the 95 mm² insulation diameter. This has been provisionally formatted as 31.4 mm for readability, but must be confirmed against the original specification before publication.
Manufacturing & Customization
Qingzhou Cable supplies medium-voltage aerial bundled cable solutions for utility distribution systems, infrastructure projects and overhead electrification applications.
Available customization options include:
- Armoured and unarmoured constructions
- Phase conductor sizes and voltage ratings
- Steel messenger conductor size
- PE or PVC outer sheath
- Metallic screen configurations
- Cable lengths and reel packaging
- Technical specifications based on customer drawings and project requirements
Frequently Asked Questions
1. What is MV ABC cable according to SANS 1713?
MV ABC cable according to SANS 1713 is a medium-voltage aerial bundled conductor designed for overhead power distribution networks, covering voltage levels from 3.8/6.6 kV to 19/33 kV, subject to the applicable cable design.
2. What voltage ratings are available for SANS 1713 MV ABC cable?
The listed voltage ratings are 3.8/6.6 kV, 6.35/11 kV, 12.7/22 kV and 19/33 kV.
3. What is the difference between Type A and Type B MV ABC cable?
Type A refers to the armoured cable design, while Type B refers to the unarmoured cable design, according to the product classification in the supplied specification.
4. What conductor material is used?
The phase conductors are stranded, compacted hard-drawn aluminium conductors, Class 2.
5. What insulation is used in MV ABC cable?
The cable uses a triple-layer TR-XLPE insulation system with semi-conductive conductor and insulation screens.
6. Is a steel messenger included?
Yes. The cable assembly includes a steel catenary or messenger conductor, with listed sizes of 50 mm² and 70 mm² in the supplied specification.
7. Can MV ABC cable be customized?
Yes. Phase conductor size, messenger configuration, metallic screening, sheath material and other project-specific requirements can be customized.
8. What standard does this MV ABC cable comply with?
The product is specified according to SANS 1713. The applicable standard edition and construction compliance should be confirmed for the specific project.
9. Is MV ABC cable suitable for overhead installation?
Yes. MV ABC is designed for aerial installation in public power distribution networks and other overhead distribution applications.
Certificate Display
Type and routine tests are issued from our own testing centre under the ISO 9001 quality system — test reports and certificates accompany every shipment.
Factory Tour
Why Choose Us
Packing & Shipping
- Wooden, steel or steel-wood drums; drum length to customer requirement
- Drum marking per customer / utility specification
- Both drum ends sealed and protected for sea freight
Ready for Your Next Cable Project?
Send us your specifications, cable schedule or RFQ — our engineering team replies with a technical proposal and price within one working day.
- Emailinfo@qzcablegroup.com
- WhatsApp / WeChat+86 173 3570 4553
- Contact personChloe · Export Department
- Factory addressWest Industrial Park, Zhulin Town, Gongyi City, Henan Province, China
Related products
High Conductivity Aluminium Alloy Conductor (AAAC) – AL5, AL6, AL7, AL57, AL59 & Alloy 1120
high conductivity aluminium alloy conductor, AAAC conductor, AAAC manufacturer, AL5 conductor, AL6 conductor, AL7 conductor, AL57 conductor, AL59 conductor, Alloy 1120 conductor, high conductivity AAAC, aluminium alloy overhead conductor, overhead transmission conductor, BS EN 50182
AAAC AL7 Conductor – All Aluminium Alloy Conductor
AAAC conductor, AAAC AL7, AL7 conductor, AL7 aluminium alloy conductor, all aluminium alloy conductor, aluminium alloy overhead conductor, AAAC conductor manufacturer, EN 50182 conductor, overhead transmission conductor, overhead distribution conductor
AAAC (AL59) Conductor – High-Strength Aluminium Alloy Conductor
AAAC conductor, AAAC AL59, AL59 conductor, aluminum alloy conductor, all aluminium alloy conductor, AAAC conductor manufacturer, SS 424 08 14, SS EN 50182, overhead alloy conductor, stranded aluminum alloy conductor, grease filled AAAC conductor
AAC (AL1) – All Aluminium Conductor
AAC conductor, AAC conductor manufacturer, all aluminium conductor, AL1 conductor, AAC overhead conductor, bare aluminium conductor, aluminium stranded conductor, SS EN 50182, overhead distribution conductor, aluminium power conductor
AAAC — Aluminum Alloy Conductor
AAAC conductor, AAAC conductor manufacturer, all aluminum alloy conductor, AAAC cable, ASTM B399 AAAC, aluminum alloy overhead conductor, overhead transmission conductor, overhead distribution conductor, AAAC 6201, bare overhead conductor
AAC — All Aluminum Conductor
AAC conductor, AAC conductor manufacturer, all aluminium conductor, all aluminum conductor, AAC cable, aluminum stranded conductor, aluminium stranded conductor, Aluminum 1350-H19 conductor, ASTM B230, ASTM B231, AS/NZS 1531, DIN 48201 Part 5, GOST 839-80, BS 215-1, BS EN 50182, IEC 61089, bare overhead conductor, overhead distribution conductor.
ACSR — Aluminum Conductor Steel Reinforced
ACSR conductor, ACSR conductor manufacturer, ACSR cable, ACSR/AW conductor, ACSR/TW conductor, aluminum conductor steel reinforced, aluminum clad steel reinforced conductor, trapezoidal wire ACSR, overhead transmission conductor, bare overhead conductor, ASTM B232, ASTM B549, ASTM B779, IEC 61089.
ACAR — Aluminum Conductor, Aluminum-Alloy Reinforced
ACAR conductor, ACAR conductor manufacturer, aluminum alloy reinforced conductor, aluminum conductor alloy reinforced, 1350/6201 conductor, ASTM B524 ACAR, overhead ACAR conductor, bare overhead conductor, overhead transmission conductor, aluminum alloy conductor
TAAAC — Thermal-Resistant All Aluminum Alloy Conductor
TAAAC - The full name: Thermal Resistant Aluminum-alloy Conductors. Urban network capacity transformation, substation, power plant construction and general lines
TACSR & TACSR/AW — Thermal-Resistant Aluminum Conductor Steel Reinforced
TACSR conductor, TACSR conductor manufacturer, thermal resistant aluminum conductor, high temperature conductor, steel reinforced aluminum conductor, overhead transmission conductor, TAL conductor, transmission line capacity upgrade, overhead power line conductor, TACSR/AW conductor
ACSS — Aluminum Conductor Steel Supported/Trapezoidal Wire
ACSS conductor, ACSS conductor manufacturer, ACSS/AW conductor, ACSS/TW conductor, aluminum conductor steel supported, high temperature overhead conductor, 250°C conductor, high ampacity conductor, overhead transmission conductor, transmission line reconductoring, low sag conductor, annealed aluminum conductor
ACS — Aluminum Clad Steel Wire
Aluminum-clad steel wire, aluminum clad steel wire manufacturer, ACS wire, ACS conductor, AW wire, AS wire, AC wire, aluminum-clad steel, aluminum clad steel core wire, ASTM B502, ASTM B415, IEC 61232, ACSR/AW conductor, OPGW wire, overhead ground wire, aluminum-clad steel strand.
GSW — Galvanized Steel Wire/Strand
galvanized steel wire strand, galvanized steel strand manufacturer, ASTM A475 steel strand, galvanized guy wire, overhead ground wire strand, galvanized steel guy strand, power transmission line strand, galvanized steel wire rope strand, Class A galvanized strand, Class B galvanized strand, Class C galvanized strand
Bare Copper & Tinned Conductor
HDBC Conductor, stranded bare copper conductor, tinned copper conductor, bare copper stranded wire, stranded tinned copper wire, bare copper conductor manufacturer, tinned copper wire manufacturer, copper grounding conductor, copper earthing conductor, concentric lay stranded copper, soft drawn copper conductor, tin coated copper wire
AACSR — Aluminum Alloy Conductor Steel Reinforced
AACSR conductor, AACSR conductor manufacturer, AACSR cable, AACSR/AW conductor, aluminum alloy conductor steel reinforced, aluminum alloy overhead conductor, aluminum clad steel reinforced conductor, 6201 aluminum alloy conductor, IEC 61089 conductor, ASTM B711 conductor, AS 3607 conductor, long span overhead conductor, high strength transmission conductor.
IEC 60502 HV Aerial Bundled Cable – 6.35/11 kV & 19/33 kV
IEC 60502 aerial bundled cable, 11kV HV ABC cable, 33kV HV ABC cable, high voltage aerial bundled cable, overhead distribution cable, XLPE insulated overhead cable, copper screened HV ABC, galvanized steel messenger cable, 11kV aerial distribution cable, 33kV aerial distribution cable
HT Aerial Bunched Cable – IS 7098-2 | 11kV & 33kV
HT aerial bunched cable, 11kV HT ABC cable, 33kV aerial bundled cable, 11kV overhead cable, 33kV overhead distribution cable, IS 7098-2 cable, high voltage ABC cable, XLPE aerial bunched cable, aluminium HT ABC cable, insulated messenger HT cable
AS/NZS 3599.1 HV XLPE Insulated Aerial Bundled Cable – 11kV & 22kV
AS/NZS 3599.1 cable, 11kV HV ABC cable, 22kV HV ABC cable, high voltage aerial bundled cable, 11kV aerial bundled cable, 22kV aerial bundled cable, screened HV ABC cable, non-screened HV ABC cable, AL XLPE HDPE cable, copper wire screened aerial cable
Medium Voltage Overhead Twisted Cable – NFA2XSY-T (SPLN 43-5)
NFA2XSY-T cable, medium voltage overhead twisted cable, MV overhead cable, XLPE overhead cable, SPLN 43-5 cable, aluminium overhead cable, overhead distribution cable, steel messenger cable
AS/NZS 3599.2 HV XLPE Insulated ABC Cable – 6.35/11 kV & 12.7/22 kV
AS/NZS 3599.2 cable, 11kV HV ABC cable, 22kV HV ABC cable, high voltage aerial bundled cable, 11kV aerial cable, 22kV aerial cable, XLPE insulated aerial cable, non metallic screened HV ABC, metallic screened HV ABC, aluminium alloy support conductor cable
LV ABC Cable – Low Voltage Aerial Bundled Cable
LV ABC cable, low voltage aerial bundled cable, ABC cable manufacturer, overhead bundled conductor, Duplex ABC cable, Triplex ABC cable, Quadruplex ABC cable, 600V aerial cable, HDPE insulated cable
16 mm² Twin Conductor Cable – AAC/PVC Parallel Aluminum Cable
16mm2 twin conductor cable, twin aluminum cable, AAC PVC parallel cable, 16mm2 parallel cable, twin overhead cable, aluminum service cable, outdoor lighting cable, overhead service conductor
NF2X / NFA2X Aerial Bundled Cable – Copper & Aluminium Conductors
NF2X cable, NFA2X cable, NF2X aerial cable, NFA2X aerial bundled cable, copper aerial bundled cable, aluminium ABC cable, XLPE overhead cable, low voltage aerial cable, HD 626 cable, VDE 0276-626
Service Drop Cable – Duplex, Triplex & Quadruplex
Duplex Service Drop Cable, Triplex Service Drop Cable, Quadruplex Service Drop Cable, Aluminum Service Cable, Overhead Service Cable, PE Insulated Service Drop Cable, XLPE Service Drop Cable, AAC Neutral Messenger, AAAC Neutral Messenger, ACSR Neutral Messenger, 600V Service Drop Cable
AMKA Cable Low Voltage Twisted Overhead Cable
AMKA cable, AMKA aerial bundled cable, AMKA-T cable, AMKA-X cable, AMK-T cable, AMK-X cable, low voltage ABC cable, aluminium aerial cable, overhead bundled conductor, HDPE insulated aerial cable, XLPE insulated aerial cable
Related solutions
Power Generation Cable Solutions
QZ Cable supplies power generation cable solutions for thermal, hydro, solar and wind power projects, including LV/MV power cables, control cables, instrumentation cables and overhead conductors.
Power Transmission Cable Solutions
QZ Cable supplies power transmission solutions, including AAC, AAAC, ACSR, ACSS, TACSR, TAAAC, OPGW and ADSS for utility, grid expansion and EPC projects worldwide.
Power Distribution Cable Solutions
Qingzhou Cable provides low- and medium-voltage cable solutions for electrical distribution networks, supporting power delivery from substations to commercial, industrial and residential users.
Power Substation Cable Solutions
Solar & Renewable Energy Cable Solutions