LV ABC Cable – Low Voltage Aerial Bundled Cable
LV & MV Aerial Cables

LV ABC Cable – Low Voltage Aerial Bundled Cable

LV ABC cable, low voltage aerial bundled cable, ABC cable manufacturer, overhead bundled conductor, Duplex ABC cable, Triplex ABC cable, Quadruplex ABC cable, 600V aerial cable, HDPE insulated cable

  • 0.6/1 kV Low Voltage Aerial Bundled Cable
  • Stranded Aluminium Conductor | Class 2
  • XLPE / PE Insulation Options | Insulated or Bare Messenger Neutral Designs
  • For Overhead Power Distribution Networks
  • Customized Specifications | Direct Factory Supply

Product Overview

LV ABC Cable (Low Voltage Aerial Bundled Cable) is designed for overhead power distribution networks with a rated voltage of 0.6/1kV. It consists of multiple insulated conductors stranded together to form a compact cable bundle, providing a reliable alternative to conventional bare overhead conductors.

QZ Cable manufactures low voltage aerial bundled cables with stranded aluminium conductors and weather-resistant insulation. Different conductor configurations, cross-sectional areas, insulation materials and neutral messenger arrangements are available according to international standards, utility specifications and project requirements.

LV ABC cables are widely used in urban and rural electricity distribution networks, service connections, secondary overhead lines, street lighting systems and temporary power supply installations.

Key Features & Advantages

  • Enhanced Electrical Safety: Insulated conductors help reduce the risk of accidental contact and short circuits caused by external objects.
  • Weather Resistance: UV-resistant insulation is suitable for long-term outdoor exposure.
  • Compact Installation: Bundled construction helps reduce conductor spacing requirements and simplifies overhead line installation.
  • Reliable Power Distribution: Stranded aluminium conductors provide an efficient solution for low-voltage electricity distribution.
  • Reduced Maintenance: Insulated construction helps reduce certain faults associated with contact between bare conductors and surrounding objects.
  • Flexible Configurations: Available in different core arrangements, conductor sizes and neutral support designs.
  • Project-Based Manufacturing: Custom designs can be supplied according to customer drawings, technical specifications and applicable standards.

Applications of LV ABC Cable

LV Aerial Bundled Cables are suitable for various low-voltage overhead distribution applications, including:

  • Urban Power Distribution: Overhead electricity distribution in residential areas, commercial districts and urban infrastructure.
  • Rural Electrification: Low-voltage power supply networks connecting villages, farms and remote communities.
  • Service Drop Connections: Connections between distribution poles and consumer service entrances.
  • Secondary Overhead Lines: Pole-to-pole low-voltage distribution circuits.
  • Street Lighting: Power supply for public lighting and road lighting networks.
  • Construction Sites: Temporary overhead power distribution for construction and infrastructure projects.

Cable Construction

LV ABC Cable generally consists of stranded aluminium conductors with individual insulation. Depending on the applicable standard and cable design, the bundle may include an insulated or bare neutral messenger/support conductor.

1. Phase Conductor

Stranded aluminium conductor, generally made of aluminium 1350 or an equivalent specified conductor material. Compact or non-compact constructions can be supplied according to the required standard.

2. Neutral / Messenger Conductor

The neutral or supporting conductor can be manufactured using aluminium, aluminium alloy or ACSR, depending on the required electrical and mechanical characteristics.

3. Insulation

UV-resistant XLPE or PE insulation is commonly used for outdoor overhead applications. Other insulation materials can be considered according to the applicable product specification.

4. Core Identification

Phase conductors can be identified by colours, longitudinal ribs or other identification methods specified by the applicable standard or utility requirements.

Product Range & Configurations

QZ Cable offers different LV ABC cable configurations for overhead distribution and service connection applications.

ConfigurationDescription
Single CoreSingle insulated conductor
DuplexTwo-core aerial service cable
TriplexThree-core aerial bundled cable
QuadruplexFour-core aerial bundled cable
3+1 CoreThree phase conductors plus neutral
3+1+1 CoreThree phase conductors, neutral and additional conductor

Available conductor cross-sections, neutral sizes and bundle arrangements depend on the selected standard and project requirements.

Specifications

ItemDescription
Product NameLV Aerial Bundled Cable
AbbreviationLV ABC Cable
Rated Voltage0.6/1kV
Phase ConductorStranded Aluminium
Conductor MaterialAluminium 1350 / As Specified
Neutral ConductorAluminium / AAAC / ACSR
InsulationXLPE / PE / As Specified
Core ConfigurationDuplex / Triplex / Quadruplex / Custom
Conductor Cross-sectionAccording to Applicable Standard
Core IdentificationColour / Rib Identification
InstallationOutdoor Overhead Installation
Temperature RatingAccording to Insulation Material and Applicable Standard
Applicable StandardsIEC / BS / NF C / HD / AS/NZS / Utility Specifications
PackagingWooden Drums / Customized Packaging

Note: The final technical parameters, dimensions, electrical characteristics and mechanical properties shall be confirmed according to the selected cable construction and applicable standard.

Applicable Standards

QZ Cable can manufacture LV Aerial Bundled Cables according to various international and national standards, including:

  • IEC: IEC 60502-1, IEC 60228
  • British Standard: BS 7870-5
  • European Standard: HD 626 S1
  • French Standard: NF C 33-209
  • Australian / New Zealand Standard: AS/NZS 3560.1
  • Utility Specifications: TNB and other local electricity authority specifications.
  • Custom Standards: Customer drawings, project specifications and other national standards.

The applicable standard depends on the required conductor construction, insulation material, voltage rating, core configuration and destination market.

How to Select the Right LV ABC Cable

Selecting the correct aerial bundled cable requires consideration of the electrical, mechanical and environmental conditions of the distribution network.

1. Rated Voltage

Confirm the network voltage and select the appropriate 0.6/1kV cable design.

2. Conductor Size

Determine the conductor cross-section based on load current, voltage drop, installation distance and short-circuit requirements.

3. Core Configuration

Choose duplex, triplex, quadruplex or other configurations according to the distribution system and service connection design.

4. Neutral Messenger Type

Confirm whether the project requires an insulated neutral, bare neutral or separate supporting messenger conductor.

5. Insulation Material

Select XLPE or PE insulation based on operating temperature, UV exposure and environmental conditions.

6. Applicable Standard

Confirm the destination country’s standard or the local utility’s technical specification before production.

Why Choose QZ Cable?

QZ Cable is a cable and conductor manufacturer established in 1969, supplying products for power transmission and distribution projects worldwide.

  • Manufacturing Experience: Cable and conductor manufacturing experience since 1969.
  • Multiple Product Categories: Overhead conductors, low-voltage and medium-voltage power cables, ABC cables and fiber-optic cables.
  • Standard-Based Production: Manufacturing according to IEC, ASTM, BS EN, AS/NZS and other applicable project standards.
  • Customized Solutions: Product designs based on customer drawings, technical specifications and project requirements.
  • Export Supply: Support for international distributors, EPC contractors, utilities and infrastructure projects.
  • Technical Documentation: Product datasheets, technical specifications and relevant test documentation according to product requirements.

Frequently Asked Questions

1. What is LV ABC Cable?

LV ABC Cable is a low-voltage aerial bundled cable consisting of multiple insulated conductors bundled together for overhead electricity distribution. It is commonly rated at 0.6/1kV.

2. What is the difference between LV ABC Cable and bare overhead conductor?

LV ABC cable has individually insulated conductors bundled together, while conventional bare overhead conductors have no individual insulation. ABC cable provides additional protection against accidental contact and certain external faults.

3. Which standards are used for LV ABC Cable?

Common standards include BS 7870-5, NF C 33-209, HD 626 S1 and AS/NZS 3560.1. IEC 60502-1 and IEC 60228 may also be referenced for applicable cable and conductor requirements.

4. What conductor materials are available?

Phase conductors are commonly manufactured from stranded aluminium. Neutral or messenger conductors can be aluminium, aluminium alloy or ACSR, depending on the cable design.

5. Is XLPE insulation available?

Yes. UV-resistant XLPE insulation is commonly used for LV ABC cables. PE and other specified insulation materials may also be available depending on the applicable standard.

6. Can LV ABC Cable be customized?

Yes. Conductor size, core configuration, neutral conductor, insulation material, core identification and packaging can be customized according to technical requirements.

7. What information is required for an LV ABC Cable quotation?

Please provide the rated voltage, applicable standard, conductor configuration, conductor cross-section, neutral conductor type, required quantity and destination port.

Request a Quote for LV ABC Cable

Looking for a reliable LV ABC Cable manufacturer for your overhead power distribution project?

QZ Cable supplies low voltage aerial bundled cables according to international standards and customer specifications.

Send us your technical requirements, drawings or bill of quantities to receive product specifications and a quotation.

Contact QZ Cable for Technical Datasheets, Pricing and Project Supply.

Technical Parameters

IEC 60502 & TNB

Phase ConductorH68 condition aluminium conductor, round stranded compressed.
Neutral or Messenger ConductorAlloy aluminium conductor, round stranded compressed.
Street Lighting ConductorH68 condition aluminium conductor, round stranded compressed.
InsulationPE.
AssemblyThe cable consists of insulated phase and street lighting aluminium conductors, shall be held firmly onto the insulated neutral messenger aluminium alloy conductor in a right hand (Z) lay.
Number of cores x nominal cross sectionmin. breaking load of conductor strandCurrent rating in the airOuter diameterTotal weight
mm^2kNAmmkg/km
1×16+1x 25 RM6.46115.3160
3×16+1x 25 RM6.46119.0290
3×25+1x 25 RM6.48423.2400
3×35+1x 25 RM6.410425.6500
3×50+1x 35 RM8.912930.0680
3×70+1x 50 RM12.116734.9920
3×95+1x 70 RM18.020940.61270
3×120+1x 70 RM18.024644.11510
3×150+1x 95 RM24.228349.21870
3×185+1×120 RM30.833254.92340
3×25+1×25+1×16 RM6.48423.2470
3×35+1×25+1×16 RM6.410425.6560
3×50+1×35+1×16 RM8.912930.0740
3×70+1×50+1×16 RM12.116734.9980
3×95+1×70+1×16 RM18.020940.61330
3×120+1×70+1×16 RM18.024644.11580
3×150+1×95+1×16 RM24.228349.21940
3×185+1×120+1×16 RM30.833254.92410

HD 626 S1

ConductorAluminium conductor, round stranded compressed (RM)
InsulationXLPE
Number of cores x nominal cross sectionmin. breaking load of conductor strandCurrent rating in the airOuter diameterTotal weight
mm^2kNAmmkg/km
2x 16 RM1,9102,572147
2x 25 RM1,2004,0107208
2x 35 RM0,8685,5132277
2x 50 RM0,6418,0165361
4x 16 RM1,9102,572286
4x 25 RM1,2004,0107430
4x 35 RM0,8685,5132553
4x 50 RM0,6418,0165746
4x 70 RM0,44310,72051009
4x 95 RM0,32013,72401332
4x 120 RM0,25318,62901632
4x 35 + 1x 35 RM0,868/0,8685,5/5,5132/132694
4x 50 + 1x 25 RM0,641/1,2008,0/4,0165/107814
4x 50 + 1x 35 RM0,641/0,8688,5/5,5165/132845
4x 70 + 1x 25 RM0,443/1,20010,7/4,0205/1071105
4x 70 + 2x 25 RM0,443/1,20010,7/4,0205/1071217
4x 70 + 1x 35 RM0,443/0,86810,7/5,5205/1321150
4x 70 + 2x 35 RM0,443/0,86810,7/5,5205/1321289
4x 95 + 1x 25 RM0,320/1,20013,7/4,0240/1071438
4x 95 + 1x 35 RM0,320/0,86813,7/5,5240/1321467
4x 95 + 2x 25 RM0,320/1,20013,7/4,0240/1071544

DES/LVC/ABC & IEC 60502

Conductor (for either phase, neutral or street lighting)The conductors shall be of H68 aluminium conductor and compacted circular stranded (RM).
InsulationXLPE.
AssemblyThe cores shall be laid up with a left-hand lay.
Number of cores x nominal cross sectionmin. breaking load of conductor strandCurrent rating in the airOuter diameterTotal weight
mm^2kNAmmkg/km
4×25 RM3.58421.5420
4×35 RM4.910423.9550
4×120+1×25 RM16.824643.81800
4×185+1×25 RM25.933250.72700

BS 7870-5:1999

Conductor (for either phase, neutral or street lighting)The conductors shall be of aluminium 1350 wires and are compacted circular stranded(RM).
InsulationXLPE. 1, 2 and 3 raised longitudinal ribs on the surface of the cores. The surface of the neutral core should have at least 12 ribs for cross-sections up to 50 mm^2 and a minimum of 16 ribs for cores above 50 mm^2. In the case of five core bundles the surface of the protective core should be smooth.
Assembly2 up to 4 cores of equal cross section are stranded together in left-hand lay, additionally 1 or 2 cores of reduced cross section can be co-stranded.
number of cores x nominal cross sectionmax. conductor- resistancemin. breaking load of conductor strandCurrent rating in the airOuter diameterTotal weight
mm^2Ohm/kmkNAmmkg/km
1x 16 RM1,9102,5728.074
1x 25 RM1,2004,01079.0106
1x 35 RM0,8685,513210.5138
1x 50 RM0,6418,016511.8182
1x 70 RM0,44310,720513.0252
1x 95 RM0,32013,724015.4333
1x 120 RM0,25318,629017.0408
1x 150 RM0,20623,233419.0502
1x 185 RM0,16428,738921.0611
1x 240 RM0,12537,246724.0801
2x 16 RM1,9102,57215.6147
2x 25 RM1,2004,010718.0208
2x 35 RM0,8685,513220.0277
2x 50 RM0,6418,016523.5361
2x 70 RM0,44310,720525.4505
2x 95 RM0,32013,724030.3666
2x 150 RM0,20623,233438.01004
4x 16 RM1,9102,57218.8286
4x 25 RM1,2004,010721.2430
4x 35 RM0,8685,513224.1553
4x 50 RM0,6418,016527.8746
4x 70 RM0,44310,720531.81009
4x 95 RM0,32013,724037.81332
4x 120 RM0,25318,629054.41632
4x 50 + 1x 25 RM0,641/1,2008,0/4,0165/10731.9814
4x 50 + 1x 35 RM0,641/0,8688,5/5,5165/13231.9845
4x 70 + 1x 25 RM0,443/1,20010,7/4,0205/10736.01105
4x 70 + 2x 25 RM0,443/1,20010,7/4,0205/10740.01217
4x 95 + 1x 25 RM0,320/1,20013,7/4,0240/10741.81438
4x 95 + 2x 25 RM0,320/1,20013,7/4,0240/10742.01544
4×120 + 1x 25 RM0,253/1,20018,6/4,0290/10759.02050

NFC 33-209

Phase ConductorAluminium conductor, round stranded compressed (RM).
Neutral ConductorAlloy aluminium conductor (AlMgSi), round stranded compressed (RM).
InsulationXLPE. Load-bearing / neutral core – marked with standard and producers phase core – marked with digits 1, 2, 3.
AssemblyCores and the neutral, conductor stranded together in right-hand lay, additionally 1, 2 or 3 cores of reduced cross section can be co-stranded.
Number of cores x nominal cross sectionmax. conductor- resistancemin. breaking load of conductor strandCurrent rating in the airOuter diameterTotal weight
mm^2Ohm/kmkNAmmkg/km
2×10 RM3.0801.53812.893
4×10 RM3.0801.53815.4183
2×16 RM1.9102.37214.8129
2×16 RN + 2×1.5 RE1.910/12.1002.37214.8176
4×16 RM1.9102.37217.8257
4×16 RN + 2×1.5 RE1.910/12.1002.37217.8304
2×25 RM1.2003.810718.0202
2×25 RM + 2×1,5 RE1.200/12.1003.810718.0249
4×25 RM1.2003.810721.7404
4×25 RM + 2×1,5 RE1.200/12.1003.810721.7451
2×35 RM0.8685.213220.8269
2×35 RM + 2×1,5 RE0.868/12.1005.213220.8316
4×35 RM0.8685.213225.1539
4×35 RM + 2×1,5 RE0.868/12.1005.213225.1586
2×50 RM0.6417.616523.4352
2×50 RM + 2×1,5 RE0.641/12.1007.616523.4399
1×54.6 RM + 3×25 RM0.630/1.2003.810721.7507
1×54.6 RM + 3×25 RM + 1×16 RM0.630/1.200/1.9103.8/2.3107/7224.3573
1×54.6 RM + 3×25 RM + 2×16 RM0.630/1.200/1.9103.8/2.3107/7229.7639
1×54.6 RM + 3×25 RM + 3×16 RM0.630/1.200/1.9103.8/2.3107/7231.1705
1×54.6 RM + 3×35 RM0.630/0.8685.213225.1615
1×54.6 RM + 3×35 RM + 1×16 RM0.630/0.868/1.9105.2/2.3132/7228.1680
1×54.6 RM + 3×35 RM + 2×16 RM0.630/0.868/1.9105.2/2.3132/7234.3748
1×54.6 RM + 3×35 RM + 3×16 RM0.630/0.868/1.9105.2/2.3132/7235.9814
1×54.6 RM + 3×35 RM + 1×25 RM0.630/0.868/1.2005.2/3.8132/10728.1714
1×54.6 RM + 3×50 RM0.630/0.6417.616528.2741
1×54.6 RM + 3×50 RM + 1×16 RM0.630/0.641/1.9107.6/2.3165/7231.6806
1×54.6 RM + 3×50 RM + 2×16 RM0.630/0.641/1.9107.6/2.3165/7238.6875
1×54.6 RM + 3×50 RM + 3×16 RM0.630/0.641/1.9107.6/2.3165/7240.4940
1×54.6 RM + 3×50 RM + 1×25 RM0.630/0.641/1.2007.6/3.8165/10731.6841
1×54.6 RM + 3×70 RM0.630/0.44310.220533.0950
1×54.6 RM + 3×70 RM + 1×16 RM0.630/0.443/1.91010.2/2.3205/7237.01014
1×54.6 RM + 3×70 RM + 2×16 RM0.630/0.443/1.91010.2/2.3205/7245.21083
1×54.6 RM + 3×70 RM + 3×16 RM0.630/0.443/1.91010.2/2.3205/7247.31148
1×54.6 RM + 3×70 RM + 1×25 RM0.630/0.443/1.20010.2/3.8205/10737.01048
1×54.6 RM + 3×70 RM + 2×25 RM0.630/0.443/1.20010.2/3.8205/10745.21150
1×54.6 RM + 3×70 RM + 3×25 RM0.630/0.443/1.20010.2/3.8205/10747.31250
1×54.6 RM + 3×95 RM0.630/0.32013.524037.41176
1×54.6 RM + 3×95 RM + 1×16 RM0.630/0.320/1.91013.5/2.3240/7241.91243

AS/NZS 3560.1

Conductor (for either phase, neutral or street lighting)The conductors shall be of aluminium 1350 wires and are compacted circular stranded (RM).
InsulationXLPE.
AssemblyThe cores shall be laid up with a left-hand lay.
Number of cores x nominal cross sectionmin. breaking load of conductor strandCurrent rating in the airOuter diameterTotal weight
mm^2kNAmmkg/km
2×16 RM4.47815.0140
2×25 RM7.010517.6210
2×35 RM9.812519.6270
2×50 RM11.415022.8370
2×95 RM15.323030.6680
3×25 RM8.89719.0310
3×35 RM9.812021.1410
3×50 RM11.414024.6550
4×16 RM8.87418.1290
4×25 RM14.09721.2410
4×35 RM19.612023.7550
4×50 RM28.014027.5740
4×70 RM39.217531.91000
4×95 RM53.221536.91370
4×120 RM67.225040.61690
4×150 RM84.028043.92020

SANS 1418

Cross SectionNominal Overall DiameterNominal WeightMinimum Bending RadiusMaximum Current Rating Air 30 ºCVoltage Drop Cos φ= 0,8
nc x mm²mmkg/kmmmAV/A.km
AL 16/214,6135215813,489
AL 25/220,52003001092,226
AL 35/3+16A+54,6N30,77054401201,632
AL 35/3+25A+54,6N33,47404501201,632
AL 50/3+54,6N30,37354401501,229
AL 50/3+16A+54,6N32,78005001501,229
AL 50/3+2x16A+54,6N36,78905401501,229
AL 50/3+25A+54,6N33,48405101501,229
AL 70/3+16A+54,6N37,91.0355601900,860
AL 70/3+2x16A+54,6N43,91.1206501900,860
AL 70/3+25A+54,6N39,91.0705901900,860
AL 95/3+54,6N36,71.1855402300,652
AL 95/3+2x16A+54,6N48,41.3457202300,652
AL 95/3+25A+54,6N43,91.2856502300,652
AL 120/3+25A+54,6N47,71.4927102730,504
AL 150/3+2x16A+54,6N57,11.7958503050,446
AL 150/3+2×9552,62.0807703050,446
AL 16/420,3266300813,489
AL 25/424,24043601092,226
AL 50/4+25A34,37955151501,229
AL 70/4+25A42,51.1045801900,860
AL 95/4+25A44,31.4106402300,652
AL 95/4+2x16A48,41.4197202300,652
AL 120/443,21.5626402730,504
AL 120/4+2x16A52,61.6957802730,504

Type 1: Self-supporting

Nominal Cross SectionPhase(AAC+UV-XLPE)Approx.Overall DiameterMax. D.C. Resistance of Conductor at 20℃
Compact ConductorUV-XLPE Insulation
No.of Individual WiresNominal Overall DiameterNominal ThicknessMin.
Thickness
Nominal Diameter
 No. X mm2–mmmmmmmmmmΩ`/km
4 X 1674.81.20.987.217.421.91
4 X 2576.01.41.168.821.31.2
4 X 3577.01.61.3410.224.680.868
4 X 5078.31.61.3411.527.830.641
4 X 701910.01.81.5213.632.910.443
4 X 951911.61.81.5215.236.780.32
4 X 1201913.01.81.5216.640.170.253
4 X 1501914.61.81.5218.244.040.206
3 X 1674.81.20.987.215.551.91
3 X 2576.01.41.168.819.011.2
3 X 3577.01.61.3410.222.030.868
3 X 5078.31.61.3411.524.840.641
3 X 701910.01.81.5213.629.380.443
3 X 951911.61.81.5215.232.830.32
3 X 1201913.01.81.5216.635.860.253
3 X 1501914.61.81.5218.239.310.206
2 X 1674.81.20.987.214.41.91
2 X 2576.01.41.168.817.61.2
2 X 3577.01.61.3410.220.40.868
2 X 5078.31.61.3411.5230.641
2 X 701910.01.81.5213.627.20.443
2 X 951911.61.81.5215.230.40.32
2 X 1201913.01.81.5216.633.20.253
2 X 1501914.61.81.5218.236.40.206
1 X 1674.81.20.987.27.21.91
1 X 2576.01.41.168.88.81.2
1 X 3577.01.61.3410.210.20.868
1 X 5078.31.61.3411.511.50.641
1 X 701910.01.81.5213.613.60.443
1 X 951911.61.81.5215.215.20.32
1 X 1201913.011.81.5216.616.60.253
1 X 1501914.61.81.5218.218.20.206

 Type 2: Phase +Supporting

Nominal Section AreaPhase(AAC+UV-XLPE)Supporting(AAAC+UV-XLPE)Approx. Overall Diameter
Phase
(AAC+UV-XLPE)
Supporting
(AAAC+UV-XLPE)
Compact ConductorUV-XLPE InsulationConductorUV-XLPE Insulation
No.of Individual WiresNominal DiameterNominal ThicknessNo./Dia.of WiresNominal Thickness
No. X mm2No. X mm2–mmmmNo./mmmmmm
3 X 161 X 54.674.81.27/3.151.620.72
3 X 251 X 54.6761.47/3.151.623.63
3 X 351 X 54.6771.67/3.151.626.17
3 X 501 X 54.678.31.67/3.151.628.53
3 X 701 X 54.619101.87/3.151.632.34
3 X 951 X 54.61911.61.87/3.151.635.24
3 X 1201 X 54.619131.87/3.151.637.78
3 X 1501 X 54.61914.61.87/3.151.640.69
3 X 161 X 7074.81.27/3.51.621.36
3 X 251 X 70761.47/3.51.624.26
3 X 351 X 70771.67/3.51.626.8
3 X 501 X 7078.31.67/3.51.629.16
3 X 701 X 7019101.87/3.51.632.97
3 X 951 X 701911.61.87/3.51.635.88
3 X 1201 X 7019131.87/3.51.638.42
3 X 1501 X 701914.61.87/3.51.641.32

 Type 3: Phase+Supporting+ Street Lighting

Nominal Section AreaPhase    SupportingService ConnectionApprox.Overall Diameter
Phase
(AAC+XLPE)
Supporting
(AAAC+XLPE)
Service Connection
(AAC+XLPE)
Compact ConductorUV-XLPEConductorUV-XLPECompact ConductorUV-XLPE
No.of Al.WireOverall Dia.Normal
Thickness
No./Dia.of Alloy WiresNormal
Thickness
No. of Al. WireOverall Dia.NominalThickness
No.Xmm2No.Xmm2No.Xmm2–mmmmNo./mmmm–mmmmmm
3 X 161 X 54.61 X 2574.81.27/3.151.676.01.427.05
3 X 251 X 54.61 X 2576.01.47/3.151.676.01.430.25
3 X 351 X 54.61 X 2577.01.67/3.151.676.01.433.05
3 X 501 X 54.61 X 2578.31.67/3.151.676.01.435.65
3 X 701 X 54.61 X 251910.01.87/3.151.676.01.439.85
3 X 951 X 54.61 X 251911.61.87/3.151.676.01.443.05
3 X 1201 X 54.61 X 251913.01.87/3.151.676.01.445.85
3 X 1501 X 54.61 X 251914.61.87/3.151.676.01.449.05
3 X 161 X 54.6 2 X 2574.81.27/3.151.676.01.427.05
3 X 251 X 54.6 2 X 2576.01.47/3.151.676.01.430.25
3 X 351 X 54.6 2 X 2577.01.67/3.151.676.01.433.05
3 X 501 X 54.6 2 X 2578.31.67/3.151.676.01.435.65
3 X 701 X 54.6 2 X 251910.01.87/3.151.676.01.439.85
3 X 951 X 54.6 2 X 251911.61.87/3.151.676.01.443.05
3 X 1201 X 54.6 2 X 251913.01.87/3.151.676.01.445.85
3 X 1501 X 54.6 2 X 251914.61.87/3.151.676.01.449.05
3 X 161 X 701 X 2574.81.27/3.151.6761.428.1
3 X 251 X 701 X 2576.01.47/3.151.6761.431.3
3 X 351 X 701 X 2577.01.67/3.151.6761.434.1
3 X 501 X 701 X 2578.31.67/3.151.6761.436.7
3 X 701 X 701 X 251910.01.87/3.151.6761.440.9
3 X  951 X 701 X 251911.61.87/3.151.6761.444.1
3 X 1201 X 701 X 251913.01.87/3.151.6761.446.9
3 X 1501 X 701 X 251914.61.87/3.151.6761.450.1
3 X 161 X 70 2 X 2574.81.27/3.151.6761.428.1
3 X 251 X 70 2 X 2576.01.47/3.151.6761.431.3
3 X 351 X 70 2 X 2577.01.67/3.151.6761.434.1
3 X 501 X 70 2 X 2578.31.67/3.151.6761.436.7
3 X 701 X 70 2 X 251910.01.87/3.151.6761.440.9
3 X 951 X 70 2 X 251911.61.87/3.151.6761.444.1
3 X 1201 X 70 2 X 251913.01.87/3.151.6761.446.9
3 X 1501 X 70 2 X 251914.61.87/3.151.6761.450.1
3 X 161 X 54.61 X 1674.81.27/3.151.674.81.227.05
3 X 251 X 54.61 X 1676.01.47/3.151.674.81.230.25
3 X 351 X 54.61 X 1677.01.67/3.151.674.81.233.05
3 X 501 X 54.61 X 1678.31.67/3.151.674.81.235.65
3 X 701 X 54.61 X 161910.01.87/3.151.674.81.239.85
3 X951 X 54.61 X 161911.61.87/3.151.674.81.243.05
3 X 1201 X 54.61 X 161913.01.87/3.151.674.81.245.85
3 X 1501 X 54.61 X 161914.61.87/3.151.674.81.249.05
3 X 161 X 54.62 X 1674.81.27/3.151.674.81.227.05
3 X 251 X 54.62 X 1676.01.47/3.151.674.81.230.25
3 X 351 X 54.62 X 1677.01.67/3.151.674.81.233.05
3 X 501 X 54.62 X 1678.31.67/3.151.674.81.235.65
3 X 701 X 54.62 X 161910.01.87/3.151.674.81.239.85
3 X 951 X 54.62 X 161911.61.87/3.151.674.81.243.05
3 X 1201 X 54.62 X 161913.01.87/3.151.674.81.245.85
3 X 1501 X 54.62 X 161914.61.87/3.151.674.81.249.05
3 X 161 X 54.61 X 1674.81.27/3.151.574.81.227.9
3 X 251 X 701 X 1676.01.47/3.151.574.81.231.1
3 X 351 X 701 X 1677.01.67/3.151.574.81.233.9
3 X 501 X 701 X 1678.31.67/3.151.574.81.236.5
3 X 701 X 701 X 161910.01.87/3.151.574.81.240.7
3 X 951 X 701 X 161911.61.87/3.151.574.81.243.9
3 X 1201 X 701 X 161913.01.87/3.151.574.81.246.7
3 X 1501 X 701 X 161914.61.87/3.151.574.81.249.9
3 X 161 X 702 X 1674.81.27/3.151.574.81.227.9
3 X 251 X 702 X 1676.01.47/3.151.574.81.231.1
3 X 351 X 702 X 1677.01.67/3.151.574.81.233.9
3 X 501 X 702 X 1678.31.67/3.151.574.81.236.5
3 X 701 X 702 X 161910.01.87/3.151.574.81.240.7
3 X 951 X 702 X 161911.61.87/3.151.574.81.243.9
3 X 1201 X 702 X 161913.01.87/3.151.574.81.246.7
3 X 1501 X 702 X 161914.61.87/3.151.574.81.249.9

Certificate Display

ISO 9001 Quality Management System
ISO 9001 Certificate (2025–2028)
ISO 9001 Certificate (NOA)
CE — Verification of Conformity
RoHS Compliance Attestation (EU)
Low Voltage Directive Attestation (EU)

Type and routine tests are issued from our own testing centre under the ISO 9001 quality system — test reports and certificates accompany every shipment.

Factory Tour

Why Choose Us

50+ years of experience Trusted manufacturing expertise since 1969
International standards IEC, ASTM, BS, CSA and other global standards
Strict quality control Comprehensive testing throughout production
Large production capacity Reliable supply for utility and EPC projects
Fast global delivery Efficient manufacturing and worldwide shipping
Technical support Expert assistance from inquiry to project completion

Packing & Shipping

  • Wooden, steel or steel-wood drums; drum length to customer requirement
  • Drum marking per customer / utility specification
  • Both drum ends sealed and protected for sea freight
Get in touch

Ready for Your Next Cable Project?

Send us your specifications, cable schedule or RFQ — our engineering team replies with a technical proposal and price within one working day.

  • Emailinfo@qzcablegroup.com
  • WhatsApp / WeChat+86 173 3570 4553
  • Contact personChloe · Export Department
  • Factory addressWest Industrial Park, Zhulin Town, Gongyi City, Henan Province, China

    The more specific the standard and size, the faster we can quote.

    Related products

    AAAC (AL59) Conductor – High-Strength Aluminium Alloy Conductor AAAC conductor, AAAC AL59, AL59 conductor, aluminum alloy conductor, all aluminium alloy conductor, AAAC conductor manufacturer, SS 424 08 14, SS EN 50182, overhead alloy conductor, stranded aluminum alloy conductor, grease filled AAAC conductor AAC (AL1) – All Aluminium Conductor AAC conductor, AAC conductor manufacturer, all aluminium conductor, AL1 conductor, AAC overhead conductor, bare aluminium conductor, aluminium stranded conductor, SS EN 50182, overhead distribution conductor, aluminium power conductor AAAC — Aluminum Alloy Conductor AAAC conductor, AAAC conductor manufacturer, all aluminum alloy conductor, AAAC cable, ASTM B399 AAAC, aluminum alloy overhead conductor, overhead transmission conductor, overhead distribution conductor, AAAC 6201, bare overhead conductor AAC — All Aluminum Conductor AAC conductor, AAC conductor manufacturer, all aluminium conductor, all aluminum conductor, AAC cable, aluminum stranded conductor, aluminium stranded conductor, Aluminum 1350-H19 conductor, ASTM B230, ASTM B231, AS/NZS 1531, DIN 48201 Part 5, GOST 839-80, BS 215-1, BS EN 50182, IEC 61089, bare overhead conductor, overhead distribution conductor. ACSR — Aluminum Conductor Steel Reinforced ACSR conductor, ACSR conductor manufacturer, ACSR cable, ACSR/AW conductor, ACSR/TW conductor, aluminum conductor steel reinforced, aluminum clad steel reinforced conductor, trapezoidal wire ACSR, overhead transmission conductor, bare overhead conductor, ASTM B232, ASTM B549, ASTM B779, IEC 61089. 16mm2 Twin Conductor Wire AAC PVC Parallel Aluminum Cable 16mm2 Twin Conductor Wire AAC PVC Parallel Aluminum Cable AMKA Cable Low Voltage Twisted Overhead Cable AMKA cable, AMKA aerial bundled cable, AMKA-T cable, AMKA-X cable, AMK-T cable, AMK-X cable, low voltage ABC cable, aluminium aerial cable, overhead bundled conductor, HDPE insulated aerial cable, XLPE insulated aerial cable 600V Covered Overhead Line Wire – AAC, AAAC & ACSR 600V covered conductor, covered overhead line wire, covered line wire manufacturer, AAC covered conductor, AAAC covered conductor, ACSR covered conductor, aluminium covered conductor, LDPE covered conductor, HDPE covered conductor, XLPE covered conductor, overhead secondary distribution wire E-A2Y 0.6/1 kV PE-Insulated Self-Supporting Aerial Cable E-A2Y cable, E-A2Y 0.6/1 kV, PE insulated aerial cable, polyethylene insulated overhead cable, self-supporting aerial cable, aluminium aerial cable, low voltage overhead cable, OVE E 8200-626 Service Drop Cable – Duplex, Triplex & Quadruplex Duplex Service Drop Cable, Triplex Service Drop Cable, Quadruplex Service Drop Cable, Aluminum Service Cable, Overhead Service Cable, PE Insulated Service Drop Cable, XLPE Service Drop Cable, AAC Neutral Messenger, AAAC Neutral Messenger, ACSR Neutral Messenger, 600V Service Drop Cable AER Cable – 0.6/1kV PE insulated aerial power cables with aluminium conductor AER cable, aerial bundled cable, AER aerial cable, low voltage ABC cable, 0.6/1 kV aerial cable, aluminium aerial cable, SFS 2200 cable, HD 626 S1 cable, rural electrification cable Pre-Assembled Aluminum Multiplex Cable – ABNT NBR 8182, 0.6/1 kV ABNT NBR 8182 0.6/1kV Preassembled Cabos De Alumínio Multiplexado ALUS-D (ABC-D) 1 kV – Halogen-Free Aluminium Aerial Bundled Cable ALUS-D 1 kV Cable, ABC-D Aerial Bundled Cable, Halogen-Free Aerial Cable, Aluminium Aerial Bundled Cable, 1 kV Aluminium Cable, PE Insulated Aerial Cable, UV-Resistant Aluminium Cable, Class 2 Aluminium Conductor Cable, Low Voltage Aerial Cable, Aerial Service Connection Cable, ABC Downlead Cable CCST (BLL) Covered Conductor – 10–52 kV | EN 50397-1 PE Insulated Covered Conductor, HDPE Sheathed Overhead Conductor, Longitudinally Water-Blocked Conductor, Medium Voltage Covered Conductor, AAAC Covered Conductor, ACSR Covered Conductor, ACSC Covered Conductor, EN 50397-1 Covered Conductor, Water-Blocked Overhead Cable CCSX-Hybrid Covered Conductor – XLPE Insulation & HDPE Sheath CCSX Hybrid, CCSX Hybrid cable, CCSX covered conductor, XLPE covered conductor, HDPE covered conductor, water blocked overhead conductor, AAAC covered conductor, ACSR covered conductor, EN 50397-1 CCSX (BLX) Covered Overhead Line Conductor – 10–52 kV CCSX cable, BLX covered conductor, CCSX conductor manufacturer, 10–52 kV covered conductor, water-blocked overhead conductor, EN 50397-1 cable, Al7 conductor, FeAl conductor SAC Spaced Aerial Cable Manufacturer – AAC Spacer Cable | ICEA S-66-524 SAC cable, spaced aerial cable, SAC cable manufacturer, spacer cable, AAC spacer cable, overhead spacer cable, 15kV SAC cable, 25kV SAC cable, 35kV SAC cable, XLPE XLPE cable, XLPE HDPE cable, ICEA S-66-524 Covered Conductors Type CC & Type CCT – AS/NZS 3675 covered conductor, CC covered conductor, CCT covered conductor, AS/NZS 3675, covered overhead conductor, XLPE covered conductor, 11kV covered conductor, 22kV covered conductor, 33kV covered conductor, spacer cable conductor, overhead distribution conductor Covered Protected Aluminium Cable – ABNT NBR 11873 Cabo Coberto de Alumínio, cabo coberto, covered protected aluminium cable, protected aluminium cable, ABNT NBR 11873 cable, spacer cable, medium voltage covered cable, 15kV protected cable, 25kV protected cable, 35kV protected cable, aerial protected cable, 1350 aluminium conductor cable Cable Semiaislado o Ecológico – Medium Voltage Covered Overhead Conductor Cable Semiaislado o Ecológico, Cable Semiaislado, Cable Ecológico Media Tensión, Conductor Cubierto de Media Tensión, Cable Cubierto para Redes Aéreas, Medium Voltage Covered Conductor, Anti-Tracking Overhead Conductor, AAC AAAC ACSR Covered Conductor PVC-Covered Aluminium Conductors – AAC & ACSR PVC covered aluminium conductor, PVC covered conductor, PVC covered overhead wire, PVC covered AAC conductor, PVC covered ACSR conductor, PVC insulated aluminium conductor, stranded aluminium overhead conductor, PVC covered power line conductor, BS 6485 conductor, BS 215 conductor Covered Aerial Medium Voltage Cable – Spacer Cable & Tree Wire Tree Wire Cable, Spacer Cable, Medium Voltage Overhead Cable, Messenger Supported Spacer Cable, Covered Overhead Conductor, Track Resistant XLPE Cable, XLPE Covered Conductor, ICEA S-121-733, AAC Tree Wire, AAAC Spacer Cable, ACSR Tree Wire ACSR-OC, ACSR/AW-OC & ACSR/AW-TR/OC – Medium Voltage Aerial Insulated Conductors ACSR-OC, ACSR/AW-OC, ACSR/AW-TR/OC, ACSR-OC cable manufacturer, ACSR/AW insulated conductor, 6.6kV aerial insulated conductor, 22.9kV overhead cable, XLPE insulated ACSR, aluminum clad steel reinforced conductor, KS C 3138, ES-6145-0021, medium voltage aerial conductor
    Inquiry WhatsApp Email