BS — Standard
MV Fire Resistant Power & Control Cables
- Conductor : Tinned copper wire stranded circular cl.
Product Description
-
MV Fire Resistant Power & Control Cables
Application and Description
These fire resistant medium voltage elastomeric insulated cables are designed for fixed wiring in ships and on mobile offshore units, suitable for use in power and control applications where fire integrity is essential.
Standards
- BS 7917
- IEC 60331-31 Fire resistant
- IEC 60332-3A Flame retardant
- IEC 60754-1; IEC 60754-2 Corrosivity
- IEC 61034-2 Smoke density
Cold bend and impact (-40°C) (on request)
CSA C22.2 No. 38-95 (on request)
Construction
| Parameter | Specification |
|---|---|
| Conductor | Tinned copper wire stranded circular cl. 2 BS 6360/IEC 60228. |
| Insulation | Mica tape + HF-EPR GP5 according to BS 7655 1.2. |
| Inner Sheath | Halogen free thermosetting compound SB1 according to BS 7917. |
| Armour | Galvanized steel wire braid or tinned bronze wire braid (single core). |
| Outer Sheath | Halogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6. |
Mechanical and Thermal Properties
Minimum Internal Bending Radius : 6×OD
Temperature Range : -40℃ ~ +90℃
Dimensions and Weight
1.9/3.3kV
| Construction No. of cores×Cross section | Nominal Insulation Thickness | Nominal Inner Sheath Thickness | Minimum Diameter Over Inner Sheath | Maximum Diameter Over Inner Sheath | Nominal Armour Wire Diameter | Nominal Outer Sheath Thickness | Minimum Overall Diameter | Maximum Overall Diameter | Approx. Weight |
|---|---|---|---|---|---|---|---|---|---|
| mm² | mm | mm | mm | mm | mm | mm | mm | mm | kg/km |
| 1×25 | 2.2 | 1.2 | 13.4 | 15.2 | 0.3 | 1.4 | 17.5 | 19.9 | 687 |
| 1×35 | 2.2 | 1.3 | 14.4 | 16.4 | 0.3 | 1.4 | 18.6 | 21.0 | 806 |
| 1×50 | 2.2 | 1.3 | 15.6 | 17.6 | 0.3 | 1.5 | 20.0 | 22.8 | 983 |
| 1×70 | 2.2 | 1.4 | 17.6 | 19.6 | 0.3 | 1.6 | 22.1 | 25.0 | 1283 |
| 1×95 | 2.4 | 1.5 | 19.8 | 22.3 | 0.3 | 1.7 | 24.5 | 27.6 | 1637 |
| 1×120 | 2.4 | 1.6 | 21.7 | 24.2 | 0.3 | 1.7 | 26.4 | 29.5 | 1997 |
| 1×150 | 2.4 | 1.6 | 23.2 | 25.8 | 0.45 | 1.8 | 28.8 | 32.0 | 2439 |
| 1×185 | 2.4 | 1.7 | 25.2 | 27.8 | 0.45 | 1.9 | 31.0 | 34.7 | 2933 |
| 1×240 | 2.4 | 1.8 | 27.9 | 30.7 | 0.45 | 2.0 | 33.9 | 37.7 | 3671 |
| 1×300 | 2.4 | 1.9 | 30.4 | 33.6 | 0.45 | 2.1 | 36.6 | 40.5 | 4446 |
| 1×400 | 2.6 | 2.0 | 34.1 | 37.5 | 0.45 | 2.3 | 40.7 | 45.2 | 5435 |
| 1×500 | 2.8 | 2.2 | 38.0 | 41.5 | 0.45 | 2.5 | 44.9 | 49.6 | 6746 |
| 1×630 | 2.8 | 2.3 | 41.6 | 45.6 | 0.45 | 2.6 | 48.8 | 54.0 | 8583 |
| 3×25 | 2.2 | 1.8 | 27.4 | 30.1 | 0.45 | 2.0 | 33.4 | 37.2 | 2072 |
| 3×35 | 2.2 | 1.8 | 29.3 | 32.4 | 0.45 | 2.1 | 35.5 | 39.3 | 2422 |
| 3×50 | 2.2 | 1.9 | 32.1 | 35.3 | 0.45 | 2.2 | 38.4 | 42.8 | 2977 |
| 3×70 | 2.2 | 2.1 | 36.2 | 39.6 | 0.45 | 2.4 | 42.9 | 47.5 | 3920 |
| 3×95 | 2.4 | 2.3 | 41.0 | 44.9 | 0.45 | 2.6 | 48.2 | 53.4 | 5041 |
| 3×120 | 2.4 | 2.4 | 44.9 | 48.9 | 0.45 | 2.7 | 52.2 | 57.6 | 6165 |
| 3×150 | 2.4 | 2.6 | 48.4 | 53.0 | 0.45 | 2.9 | 56.2 | 61.7 | 7333 |
| 3×185 | 2.4 | 2.7 | 52.5 | 57.2 | 0.45 | 3.0 | 60.5 | 66.6 | 8800 |
| 3×240 | 2.4 | 3.0 | 58.5 | 63.8 | 0.45 | 3.3 | 67.0 | 73.4 | 11172 |
| 3×300 | 2.4 | 3.2 | 64.0 | 69.4 | 0.45 | 3.5 | 72.8 | 79.9 | 13587 |
3.3/3.3kV
| Construction No. of cores×Cross section | Nominal Insulation Thickness | Nominal Inner Sheath Thickness | Minimum Diameter Over Inner Sheath | Maximum Diameter Over Inner Sheath | Nominal Armour Wire Diameter | Nominal Outer Sheath Thickness | Minimum Overall Diameter | Maximum Overall Diameter | Approx. Weight |
|---|---|---|---|---|---|---|---|---|---|
| mm² | mm | mm | mm | mm | mm | mm | mm | mm | kg/km |
| 1×25 | 3.0 | 1.3 | 15.1 | 17.1 | 0.3 | 1.5 | 19.4 | 22.3 | 789 |
| 1×35 | 3.0 | 1.3 | 16.0 | 18.0 | 0.3 | 1.5 | 20.3 | 23.2 | 900 |
| 1×50 | 3.0 | 1.4 | 17.4 | 19.4 | 0.3 | 1.6 | 21.9 | 24.8 | 1097 |
| 1×70 | 3.0 | 1.5 | 19.3 | 21.7 | 0.3 | 1.6 | 23.8 | 26.8 | 1392 |
| 1×95 | 3.0 | 1.5 | 21.0 | 23.5 | 0.3 | 1.7 | 25.7 | 28.8 | 1715 |
| 1×120 | 3.0 | 1.6 | 22.9 | 25.4 | 0.3 | 1.8 | 27.8 | 30.9 | 2097 |
| 1×150 | 3.0 | 1.7 | 24.5 | 27.2 | 0.45 | 1.9 | 30.3 | 34.0 | 2568 |
| 1×185 | 3.0 | 1.7 | 26.3 | 29.0 | 0.45 | 2.0 | 32.3 | 36.1 | 3050 |
| 1×240 | 3.0 | 1.8 | 29.0 | 32.2 | 0.45 | 2.1 | 35.2 | 39.1 | 3798 |
| 1×300 | 3.0 | 1.9 | 31.6 | 34.8 | 0.45 | 2.2 | 37.9 | 41.9 | 4582 |
| 1×400 | 3.0 | 2.1 | 35.1 | 38.5 | 0.45 | 2.3 | 41.7 | 46.2 | 5533 |
| 1×500 | 3.2 | 2.2 | 38.7 | 42.6 | 0.45 | 2.5 | 45.7 | 50.4 | 6828 |
| 1×630 | 3.2 | 2.4 | 43.6 | 46.6 | 0.45 | 2.6 | 49.7 | 55.0 | 8712 |
| 3×25 | 3.0 | 1.9 | 30.9 | 34.1 | 0.45 | 2.1 | 37.1 | 41.1 | 2358 |
| 3×35 | 3.0 | 2.0 | 33.0 | 36.2 | 0.45 | 2.2 | 39.4 | 43.8 | 2747 |
| 3×50 | 3.0 | 2.1 | 35.8 | 39.1 | 0.45 | 2.3 | 42.3 | 46.9 | 3325 |
| 3×70 | 3.0 | 2.2 | 39.7 | 43.5 | 0.45 | 2.5 | 46.6 | 51.4 | 4274 |
| 3×95 | 3.0 | 2.4 | 43.7 | 47.7 | 0.45 | 2.7 | 51.1 | 56.4 | 5347 |
| 3×120 | 3.0 | 2.5 | 47.5 | 51.7 | 0.45 | 2.8 | 55.1 | 60.6 | 6493 |
| 3×150 | 3.0 | 2.7 | 51.1 | 55.7 | 0.45 | 3.0 | 59.0 | 65.1 | 7684 |
| 3×185 | 3.0 | 2.8 | 55.2 | 60.0 | 0.45 | 3.2 | 63.5 | 69.8 | 9213 |
| 3×240 | 3.0 | 3.1 | 61.2 | 66.6 | 0.45 | 3.4 | 69.9 | 76.8 | 11583 |
| 3×300 | 3.0 | 3.3 | 66.6 | 72.2 | 0.45 | 3.6 | 75.7 | 82.9 | 14031 |
-
MV Flame Retardant Power & Control Cables
Application and Description
These medium voltage elastomeric insulated cables are designed for fixed wiring in ships and on mobile offshore units, suitable for use in power and control applications.
Standards
- BS 6883
- IEC 60332-3A Flame retardant
- IEC 60754-1; IEC 60754- 2 Corrosivity
- IEC 61034-2 Smoke density
Cold bend and impact (-40°C) (on request)
CSA C22.2 No. 38-95 (on request)
Construction
| Parameter | Specification |
|---|---|
| Conductor | Tinned copper wire stranded circular cl. 2 BS 6360/IEC 60228. |
| Insulation | HF-EPR GP5 according to BS 7655 1.2. |
| Inner Sheath | Halogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6. |
| Armour | Galvanized steel wire braid or tinned bronze wire braid (single core). |
| Outer Sheath | Halogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6. |
Mechanical and Thermal Properties
Minimum Internal Bending Radius : 6×OD
Temperature Range : -40℃ ~ +90℃
Dimensions and Weight
1.9/3.3kV
| Construction No. of cores×Cross section | Nominal Insulation Thickness | Nominal Inner Sheath Thickness | Minimum Diameter Over Inner Sheath | Maximum Diameter Over Inner Sheath | Nominal Armour Wire Diameter | Nominal Outer Sheath Thickness | Minimum Overall Diameter | Maximum Overall Diameter | Approx. Weight |
|---|---|---|---|---|---|---|---|---|---|
| mm² | mm | mm | mm | mm | mm | mm | mm | mm | kg/km |
| 1×10 | 2.2 | 1.1 | 10.2 | 11.9 | 0.3 | 1.3 | 14.2 | 16.2 | 398 |
| 1×16 | 2.2 | 1.2 | 11.4 | 13.1 | 0.3 | 1.3 | 15.4 | 17.6 | 499 |
| 1×25 | 2.2 | 1.2 | 13.0 | 14.8 | 0.3 | 1.4 | 17.1 | 19.5 | 675 |
| 1×35 | 2.2 | 1.3 | 14.1 | 15.9 | 0.3 | 1.4 | 18.2 | 20.6 | 793 |
| 1×50 | 2.2 | 1.3 | 15.3 | 17.2 | 0.3 | 1.5 | 19.6 | 22.4 | 970 |
| 1×70 | 2.2 | 1.4 | 17.2 | 19.2 | 0.3 | 1.6 | 21.7 | 24.6 | 1269 |
| 1×95 | 2.4 | 1.5 | 19.4 | 21.9 | 0.3 | 1.7 | 24.2 | 27.2 | 1623 |
| 1×120 | 2.4 | 1.6 | 21.3 | 23.8 | 0.3 | 1.7 | 26.0 | 29.1 | 1983 |
| 1×150 | 2.4 | 1.6 | 22.8 | 25.4 | 0.45 | 1.8 | 28.4 | 31.6 | 2423 |
| 1×185 | 2.4 | 1.7 | 24.8 | 27.4 | 0.45 | 1.9 | 30.6 | 34.3 | 2917 |
| 1×240 | 2.4 | 1.8 | 27.5 | 30.3 | 0.45 | 2.0 | 33.5 | 37.3 | 3654 |
| 1×300 | 2.4 | 1.9 | 30.0 | 33.2 | 0.45 | 2.1 | 36.2 | 40.1 | 4428 |
| 1×400 | 2.6 | 2.0 | 33.8 | 37.1 | 0.45 | 2.3 | 40.3 | 44.8 | 5416 |
| 1×500 | 2.8 | 2.2 | 37.6 | 41.1 | 0.45 | 2.5 | 44.5 | 49.2 | 6726 |
| 1×630 | 2.8 | 2.3 | 41.2 | 45.2 | 0.45 | 2.6 | 48.4 | 53.6 | 8562 |
| 3×10 | 2.2 | 1.5 | 20.4 | 22.9 | 0.3 | 1.7 | 25.1 | 28.2 | 1052 |
| 3×16 | 2.2 | 1.6 | 22.8 | 25.3 | 0.3 | 1.8 | 27.7 | 30.8 | 1357 |
| 3×25 | 2.2 | 1.8 | 26.6 | 29.3 | 0.45 | 2.0 | 32.6 | 36.3 | 2032 |
| 3×35 | 2.2 | 1.8 | 28.4 | 31.2 | 0.45 | 2.1 | 34.6 | 38.5 | 2382 |
| 3×50 | 2.2 | 1.9 | 31.2 | 34.4 | 0.45 | 2.2 | 37.6 | 41.6 | 2936 |
| 3×70 | 2.2 | 2.1 | 35.3 | 38.7 | 0.45 | 2.4 | 42.1 | 46.7 | 3877 |
| 3×95 | 2.4 | 2.3 | 40.2 | 44.1 | 0.45 | 2.6 | 47.4 | 52.1 | 4995 |
| 3×120 | 2.4 | 2.4 | 44.0 | 48.1 | 0.45 | 2.7 | 51.4 | 56.7 | 6118 |
| 3×150 | 2.4 | 2.6 | 47.6 | 51.8 | 0.45 | 2.9 | 55.3 | 60.8 | 7284 |
| 3×185 | 2.4 | 2.7 | 51.7 | 56.4 | 0.45 | 3.0 | 59.6 | 65.7 | 8750 |
| 3×240 | 2.4 | 3.0 | 57.7 | 62.9 | 0.45 | 3.3 | 66.2 | 72.6 | 11118 |
| 3×300 | 2.4 | 3.2 | 63.1 | 68.6 | 0.45 | 3.5 | 72.0 | 79.0 | 13531 |
3.3/3.3kV
| Construction No. of cores×Cross section | Nominal Insulation Thickness | Nominal Inner Sheath Thickness | Minimum Diameter Over Inner Sheath | Maximum Diameter Over Inner Sheath | Nominal Armour Wire Diameter | Nominal Outer Sheath Thickness | Minimum Overall Diameter | Maximum Overall Diameter | Approx. Weight |
|---|---|---|---|---|---|---|---|---|---|
| mm² | mm | mm | mm | mm | mm | mm | mm | mm | kg/km |
| 1×10 | 3.0 | 1.2 | 12.0 | 13.7 | 0.3 | 1.4 | 16.1 | 18.4 | 483 |
| 1×16 | 3.0 | 1.2 | 13.0 | 14.7 | 0.3 | 1.4 | 17.1 | 19.4 | 579 |
| 1×25 | 3.0 | 1.3 | 14.7 | 16.7 | 0.3 | 1.5 | 19.1 | 21.5 | 774 |
| 1×35 | 3.0 | 1.3 | 15.6 | 17.6 | 0.3 | 1.5 | 19.9 | 22.8 | 885 |
| 1×50 | 3.0 | 1.4 | 17.0 | 19.0 | 0.3 | 1.6 | 21.5 | 24.4 | 1082 |
| 1×70 | 3.0 | 1.5 | 18.9 | 21.0 | 0.3 | 1.6 | 23.4 | 26.4 | 1377 |
| 1×95 | 3.0 | 1.5 | 20.6 | 23.1 | 0.3 | 1.7 | 25.3 | 28.4 | 1699 |
| 1×120 | 3.0 | 1.6 | 22.5 | 25.0 | 0.3 | 1.8 | 27.4 | 30.5 | 2081 |
| 1×150 | 3.0 | 1.7 | 24.1 | 26.8 | 0.45 | 1.9 | 30.0 | 33.6 | 2550 |
| 1×185 | 3.0 | 1.7 | 26.0 | 28.6 | 0.45 | 2.0 | 32.0 | 35.7 | 3032 |
| 1×240 | 3.0 | 1.8 | 28.7 | 31.8 | 0.45 | 2.1 | 34.8 | 38.7 | 3780 |
| 1×300 | 3.0 | 1.9 | 31.2 | 34.4 | 0.45 | 2.2 | 37.6 | 41.5 | 4563 |
| 1×400 | 3.0 | 2.1 | 34.7 | 38.1 | 0.45 | 2.3 | 41.3 | 45.8 | 5514 |
| 1×500 | 3.2 | 2.2 | 38.4 | 41.9 | 0.45 | 2.5 | 45.3 | 50.0 | 6807 |
| 1×630 | 3.2 | 2.4 | 42.2 | 46.2 | 0.45 | 2.6 | 49.4 | 54.6 | 8691 |
| 3×10 | 3.0 | 1.7 | 24.1 | 26.7 | 0.45 | 1.9 | 29.9 | 33.6 | 1404 |
| 3×16 | 3.0 | 1.8 | 26.5 | 29.2 | 0.45 | 2.0 | 32.5 | 36.2 | 1738 |
| 3×25 | 3.0 | 1.9 | 30.1 | 33.2 | 0.45 | 2.1 | 36.3 | 40.2 | 2314 |
| 3×35 | 3.0 | 2.0 | 32.1 | 35.4 | 0.45 | 2.2 | 38.5 | 42.9 | 2701 |
| 3×50 | 3.0 | 2.1 | 34.9 | 38.3 | 0.45 | 2.3 | 41.5 | 46.0 | 3278 |
| 3×70 | 3.0 | 2.2 | 38.9 | 42.7 | 0.45 | 2.5 | 45.8 | 50.5 | 4226 |
| 3×95 | 3.0 | 2.4 | 42.9 | 46.9 | 0.45 | 2.7 | 50.2 | 55.5 | 5297 |
| 3×120 | 3.0 | 2.5 | 46.7 | 50.9 | 0.45 | 2.8 | 54.2 | 59.7 | 6442 |
| 3×150 | 3.0 | 2.7 | 50.3 | 54.9 | 0.45 | 3.0 | 58.2 | 64.2 | 7631 |
| 3×185 | 3.0 | 2.8 | 54.4 | 59.2 | 0.45 | 3.2 | 62.7 | 68.9 | 9158 |
| 3×240 | 3.0 | 3.1 | 60.4 | 65.7 | 0.45 | 3.4 | 69.1 | 76.0 | 11526 |
Application and Description
These medium voltage elastomeric insulated cables are designed for fixed wiring in ships and on mobile offshore units, suitable for use in power and control applications.
Standards
- BS 6883
- IEC 60332-3A Flame retardant
- IEC 60754-1; IEC 60754- 2 Corrosivity
- IEC 61034-2 Smoke density
Cold bend and impact (-40°C) (on request)
CSA C22.2 No. 38-95 (on request)
Construction
| Parameter | Specification |
|---|---|
| Conductor | Tinned copper wire stranded circular cl. 2 BS 6360/IEC 60228. |
| Conductor Screen | Semiconducting layer or tape. |
| Insulation | HF-EPR GP5 according to BS 7655 1.2. |
| Insulation Screen | Semiconducting layer or tape +Tinned copper tape. |
| Outer Sheath | Halogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6. |
Mechanical and Thermal Properties
Minimum Internal Bending Radius : 15×OD (single core); 20×OD (three core)
Temperature Range : -40℃ ~ +90℃
Dimensions and Weight
3.8/6.6kV
| Construction No. of cores×Cross section | Nominal Insulation Thickness | Nominal Outer Sheath Thickness | Minimum Overall Diameter | Maximum Overall Diameter | Approx. Weight |
|---|---|---|---|---|---|
| mm² | mm | mm | mm | mm | kg/km |
| 1×16 | 3.0 | 1.3 | 16.0 | 18.0 | 492 |
| 1×25 | 3.0 | 1.3 | 17.6 | 19.7 | 658 |
| 1×35 | 3.0 | 1.4 | 18.7 | 20.8 | 776 |
| 1×50 | 3.0 | 1.4 | 19.9 | 22.3 | 942 |
| 1×70 | 3.0 | 1.5 | 21.8 | 24.3 | 1229 |
| 1×95 | 3.0 | 1.6 | 23.7 | 26.3 | 1546 |
| 1×120 | 3.0 | 1.6 | 25.4 | 28.0 | 1890 |
| 1×150 | 3.0 | 1.7 | 27.0 | 29.8 | 2242 |
| 1×185 | 3.0 | 1.8 | 29.0 | 32.1 | 2713 |
| 1×240 | 3.0 | 1.9 | 31.7 | 35.0 | 3427 |
| 1×300 | 3.0 | 2.0 | 34.3 | 37.6 | 4177 |
| 1×400 | 3.0 | 2.1 | 37.6 | 41.1 | 5145 |
| 1×500 | 3.2 | 2.3 | 41.4 | 45.5 | 6408 |
| 1×630 | 3.2 | 2.4 | 45.1 | 49.2 | 8134 |
| 3×16 | 3.0 | 1.8 | 32.7 | 36.0 | 1482 |
| 3×25 | 3.0 | 2.0 | 36.5 | 39.9 | 2031 |
| 3×35 | 3.0 | 2.0 | 38.4 | 41.9 | 2359 |
| 3×50c | 3.0 | 2.2 | 41.3 | 45.3 | 2918 |
| 3×70 | 3.0 | 2.3 | 45.3 | 49.4 | 3788 |
| 3×95 | 3.0 | 2.5 | 49.3 | 53.9 | 4776 |
| 3×120 | 3.0 | 2.6 | 53.1 | 57.8 | 5868 |
| 3×150 | 3.0 | 2.7 | 56.5 | 61.4 | 6933 |
| 3×185 | 3.0 | 2.9 | 60.8 | 66.1 | 8401 |
| 3×240 | 3.0 | 3.1 | 66.6 | 72.2 | 10616 |
6.35/11kV
| Construction No. of cores×Cross section | Nominal Insulation Thickness | Nominal Outer Sheath Thickness | Minimum Overall Diameter | Maximum Overall Diameter | Approx. Weight |
|---|---|---|---|---|---|
| mm² | mm | mm | mm | mm | kg/km |
| 1×16 | 3.4 | 1.3 | 16.8 | 18.8 | 524 |
| 1×25 | 3.4 | 1.4 | 18.6 | 20.7 | 704 |
| 1×35 | 3.4 | 1.4 | 19.4 | 21.9 | 813 |
| 1×50 | 3.4 | 1.5 | 20.8 | 23.3 | 994 |
| 1×70 | 3.4 | 1.5 | 22.6 | 25.1 | 1272 |
| 1×95 | 3.4 | 1.6 | 24.4 | 27.1 | 1592 |
| 1×120 | 3.4 | 1.7 | 26.3 | 29.0 | 1956 |
| 1×150 | 3.4 | 1.7 | 27.8 | 30.6 | 2294 |
| 1×185 | 3.4 | 1.8 | 29.8 | 32.9 | 2769 |
| 1×240 | 3.4 | 1.9 | 32.5 | 35.8 | 3487 |
| 1×300 | 3.4 | 2.0 | 35.0 | 38.4 | 4242 |
| 1×400 | 3.4 | 2.1 | 38.4 | 41.9 | 5208 |
| 1×500 | 3.4 | 2.3 | 41.8 | 45.8 | 6442 |
| 1×630 | 3.4 | 2.4 | 45.5 | 49.6 | 8176 |
| 3×16 | 3.4 | 1.9 | 34.5 | 37.9 | 1601 |
| 3×25 | 3.4 | 2.0 | 38.2 | 41.6 | 2139 |
| 3×35 | 3.4 | 2.1 | 40.2 | 44.1 | 2497 |
| 3×50 | 3.4 | 2.2 | 43.0 | 47.0 | 3040 |
| 3×70 | 3.4 | 2.4 | 47.1 | 51.3 | 3949 |
| 3×95 | 3.4 | 2.5 | 51.0 | 55.6 | 4919 |
| 3×120 | 3.4 | 2.7 | 55.0 | 59.8 | 6055 |
| 3×150 | 3.4 | 2.8 | 58.4 | 63.3 | 7132 |
| 3×185 | 3.4 | 3.0 | 62.7 | 68.1 | 8613 |
| 3×240 | 3.4 | 3.2 | 68.5 | 74.1 | 10848 |
8.7/15kV
| Construction No. of cores×Cross section | Nominal Insulation Thickness | Nominal Outer Sheath Thickness | Minimum Overall Diameter | Maximum Overall Diameter | Approx. Weight |
|---|---|---|---|---|---|
| mm² | mm | mm | mm | mm | kg/km |
| 1×25 | 4.5 | 1.5 | 20.9 | 23.4 | 808 |
| 1×35 | 4.5 | 1.5 | 21.7 | 24.3 | 921 |
| 1×50 | 4.5 | 1.5 | 22.9 | 25.5 | 1110 |
| 1×70 | 4.5 | 1.6 | 24.9 | 27.5 | 1396 |
| 1×95 | 4.5 | 1.7 | 26.7 | 29.5 | 1726 |
| 1×120 | 4.5 | 1.8 | 28.6 | 31.4 | 2099 |
| 1×150 | 4.5 | 1.8 | 30.1 | 33.3 | 2445 |
| 1×185 | 4.5 | 1.9 | 32.1 | 35.3 | 2929 |
| 1×240 | 4.5 | 2.0 | 34.8 | 38.2 | 3661 |
| 1×300 | 4.5 | 2.1 | 37.3 | 40.8 | 4429 |
| 1×400 | 4.5 | 2.2 | 40.7 | 44.6 | 5390 |
| 1×500 | 4.5 | 2.4 | 44.1 | 48.2 | 6638 |
| 1×630 | 4.5 | 2.5 | 47.8 | 52.0 | 8415 |
| 3×25 | 4.5 | 2.2 | 43.1 | 47.1 | 2458 |
| 3×35 | 4.5 | 2.3 | 45.2 | 49.2 | 2832 |
| 3×50 | 4.5 | 2.4 | 47.9 | 52.1 | 3395 |
| 3×70 | 4.5 | 2.6 | 52.1 | 56.7 | 4336 |
| 3×95 | 4.5 | 2.7 | 55.9 | 60.7 | 5334 |
| 3×120 | 4.5 | 2.9 | 59.9 | 64.9 | 6500 |
| 3×150 | 4.5 | 3.0 | 63.3 | 68.7 | 7602 |
| 3×185 | 4.5 | 3.2 | 67.6 | 73.2 | 9116 |
Application and Description
These medium voltage elastomeric insulated cables are designed for fixed wiring in ships and on mobile offshore units, suitable for use in power and control applications.
Standards
- BS 6883
- IEC 60332-3A Flame retardant
- IEC 60754-1; IEC 60754- 2 Corrosivity
- IEC 61034-2 Smoke density
Cold bend and impact (-40°C) (on request)
CSA C22.2 No. 38-95 (on request)
Construction
| Parameter | Specification |
|---|---|
| Conductor | Tinned copper wire stranded circular cl. 2 BS 6360/IEC 60228. |
| Conductor Screen | Semiconducting layer or tape. |
| Insulation | HF-EPR GP5 according to BS 7655 1.2. |
| Insulation Screen | Semiconducting layer or tape +Tinned copper tape. |
| Inner Sheath | Halogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6. |
| Armour | Galvanized steel wire braid or tinned bronze wire braid (single core). |
| Outer Sheath | Halogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6. |
Mechanical and Thermal Properties
Minimum Internal Bending Radius : 15×OD (single core); 20×OD (three core)
Temperature Range : -40℃ ~ +90℃
Dimensions and Weight
3.8/6.6kV
| Construction No. of cores×Cross section | Nominal Insulation Thickness | Nominal Inner Sheath Thickness | Minimum Diameter Over Inner Sheath | Maximum Diameter Over Inner Sheath | Nominal Armour Wire Diameter | Nominal Outer Sheath Thickness | Minimum Overall Diameter | Maximum Overall Diameter | Approx. Weight |
|---|---|---|---|---|---|---|---|---|---|
| mm² | mm | mm | mm | mm | mm | mm | mm | mm | kg/km |
| 1×16 | 3.0 | 1.3 | 16.0 | 18.0 | 0.3 | 1.4 | 20.2 | 23.0 | 790 |
| 1×25 | 3.0 | 1.3 | 17.6 | 19.7 | 0.3 | 1.5 | 21.9 | 24.9 | 950 |
| 1×35 | 3.0 | 1.4 | 18.7 | 20.8 | 0.3 | 1.5 | 23.0 | 26.0 | 1060 |
| 1×50 | 3.0 | 1.4 | 19.9 | 22.3 | 0.3 | 1.6 | 24.4 | 27.4 | 1320 |
| 1×70 | 3.0 | 1.5 | 21.8 | 24.3 | 0.3 | 1.7 | 26.5 | 29.6 | 1610 |
| 1×95 | 3.0 | 1.6 | 23.7 | 26.3 | 0.3 | 1.8 | 28.6 | 31.8 | 1930 |
| 1×120 | 3.0 | 1.6 | 25.4 | 28.0 | 0.3 | 1.8 | 30.2 | 33.9 | 2260 |
| 1×150 | 3.0 | 1.7 | 27.0 | 29.8 | 0.45 | 1.9 | 32.8 | 36.6 | 2760 |
| 1×185 | 3.0 | 1.8 | 29.0 | 32.1 | 0.45 | 2.0 | 35.0 | 38.9 | 3210 |
| 1×240 | 3.0 | 1.9 | 31.7 | 35.0 | 0.45 | 2.1 | 37.9 | 41.9 | 3960 |
| 1×300 | 3.0 | 2.0 | 34.3 | 37.6 | 0.45 | 2.2 | 40.6 | 45.1 | 4660 |
| 1×400 | 3.0 | 2.1 | 37.6 | 41.4 | 0.45 | 2.4 | 44.4 | 49.0 | 5470 |
| 1×500 | 3.2 | 2.3 | 41.4 | 45.4 | 0.45 | 2.5 | 48.4 | 53.6 | 6610 |
| 1×630 | 3.2 | 2.4 | 45.1 | 49.2 | 0.45 | 2.7 | 52.4 | 57.8 | 8230 |
| 3×16 | 3.0 | 1.8 | 32.7 | 36.0 | 0.45 | 2.1 | 38.9 | 43.3 | 2610 |
| 3×25 | 3.0 | 2.0 | 36.5 | 39.9 | 0.45 | 2.2 | 42.9 | 47.5 | 3220 |
| 3×35 | 3.0 | 2.0 | 38.4 | 41.9 | 0.45 | 2.3 | 44.9 | 49.6 | 3700 |
| 3×50 | 3.0 | 2.2 | 41.3 | 45.3 | 0.45 | 2.4 | 48.1 | 53.3 | 4360 |
| 3×70 | 3.0 | 2.3 | 45.3 | 49.4 | 0.45 | 2.6 | 52.4 | 57.4 | 5410 |
| 3×95 | 3.0 | 2.5 | 49.3 | 53.9 | 0.45 | 2.8 | 56.8 | 62.4 | 6710 |
| 3×120 | 3.0 | 2.6 | 53.1 | 57.8 | 0.45 | 2.9 | 60.8 | 67.0 | 7770 |
| 3×150 | 3.0 | 2.7 | 56.6 | 61.4 | 0.45 | 3.1 | 64.6 | 70.9 | 9160 |
| 3×185 | 3.0 | 2.9 | 60.8 | 66.1 | 0.45 | 3.2 | 69.1 | 76.0 | 10430 |
| 3×240 | 3.0 | 3.1 | 66.6 | 72.2 | 0.45 | 3.5 | 75.5 | 82.6 | 12840 |
6.35/11kV
| Construction No. of cores×Cross section | Nominal Insulation Thickness | Nominal Inner Sheath Thickness | Minimum Diameter Over Inner Sheath | Maximum Diameter Over Inner Sheath | Nominal Armour Wire Diameter | Nominal Outer Sheath Thickness | Minimum Overall Diameter | Maximum Overall Diameter | Approx. Weight |
|---|---|---|---|---|---|---|---|---|---|
| mm² | mm | mm | mm | mm | mm | mm | mm | mm | kg/km |
| 1×16 | 3.4 | 1.3 | 16.8 | 18.8 | 0.3 | 1.5 | 21.1 | 24 | 810 |
| 1×25 | 3.4 | 1.4 | 18.6 | 20.7 | 0.3 | 1.5 | 22.9 | 25.9 | 980 |
| 1×35 | 3.4 | 1.4 | 19.4 | 21.9 | 0.3 | 1.6 | 24.0 | 27.0 | 1110 |
| 1×50 | 3.4 | 1.5 | 20.8 | 23.3 | 0.3 | 1.6 | 25.3 | 28.4 | 1360 |
| 1×70 | 3.4 | 1.5 | 22.6 | 25.1 | 0.3 | 1.7 | 27.3 | 30.4 | 1660 |
| 1×95 | 3.4 | 1.6 | 24.4 | 27.1 | 0.3 | 1.8 | 29.3 | 33.0 | 1970 |
| 1×120 | 3.4 | 1.7 | 26.3 | 29.0 | 0.45 | 1.9 | 32.1 | 35.9 | 2360 |
| 1×150 | 3.4 | 1.7 | 27.8 | 30.6 | 0.45 | 2.0 | 33.8 | 37.6 | 2810 |
| 1×185 | 3.4 | 1.8 | 29.8 | 32.9 | 0.45 | 2.0 | 35.8 | 39.7 | 3260 |
| 1×240 | 3.4 | 1.9 | 32.5 | 35.8 | 0.45 | 2.2 | 38.9 | 43.3 | 4020 |
| 1×300 | 3.4 | 2.0 | 35.0 | 38.4 | 0.45 | 2.3 | 41.6 | 46.1 | 4760 |
| 1×400 | 3.4 | 2.1 | 38.4 | 41.9 | 0.45 | 2.4 | 45.1 | 49.8 | 5610 |
| 1×500 | 3.4 | 2.3 | 41.8 | 45.8 | 0.45 | 2.5 | 48.8 | 54.0 | 6820 |
| 1×630 | 3.4 | 2.4 | 45.5 | 49.6 | 0.45 | 2.7 | 52.8 | 58.2 | 8480 |
| 3×16 | 3.4 | 1.9 | 34.5 | 37.9 | 0.45 | 2.1 | 40.7 | 45.2 | 2660 |
| 3×25 | 3.4 | 2.0 | 38.2 | 41.6 | 0.45 | 2.3 | 44.7 | 49.4 | 3310 |
| 3×35 | 3.4 | 2.1 | 40.2 | 44.1 | 0.45 | 2.4 | 47.0 | 51.7 | 3960 |
| 3×50 | 3.4 | 2.2 | 43.0 | 47.0 | 0.45 | 2.5 | 50.0 | 55.2 | 4570 |
| 3×70 | 3.4 | 2.4 | 47.1 | 51.3 | 0.45 | 2.7 | 54.4 | 59.9 | 5610 |
| 3×95 | 3.4 | 2.5 | 51.0 | 55.6 | 0.45 | 2.8 | 58.5 | 64.5 | 6820 |
| 3×120 | 3.4 | 2.7 | 55.0 | 59.8 | 0.45 | 3.0 | 62.9 | 69.1 | 8070 |
| 3×150 | 3.4 | 2.8 | 58.4 | 63.3 | 0.45 | 3.1 | 66.5 | 72.8 | 9260 |
| 3×185 | 3.4 | 3.0 | 62.7 | 68.1 | 0.45 | 3.3 | 71.2 | 78.1 | 10960 |
| 3×240 | 3.4 | 3.2 | 68.5 | 74.1 | 0.45 | 3.6 | 77.5 | 85.2 | 13390 |
8.7/15kV
| Construction No. of cores×Cross section | Nominal Insulation Thickness | Nominal Inner Sheath Thickness | Minimum Diameter Over Inner Sheath | Maximum Diameter Over Inner Sheath | Nominal Armour Wire Diameter | Nominal Outer Sheath Thickness | Minimum Overall Diameter | Maximum Overall Diameter | Approx. Weight |
|---|---|---|---|---|---|---|---|---|---|
| mm² | mm | mm | mm | mm | mm | mm | mm | mm | kg/km |
| 1×25 | 4.5 | 1.5 | 20.9 | 23.4 | 0.3 | 1.6 | 25.4 | 28.5 | 1150 |
| 1×35 | 4.5 | 1.5 | 21.7 | 24.3 | 0.3 | 1.7 | 26.4 | 29.6 | 1260 |
| 1×50 | 4.5 | 1.5 | 22.9 | 25.5 | 0.3 | 1.7 | 27.6 | 30.8 | 1510 |
| 1×70 | 4.5 | 1.6 | 24.9 | 27.5 | 0.3 | 1.8 | 29.8 | 33.4 | 1770 |
| 1×95 | 4.5 | 1.7 | 26.7 | 29.5 | 0.45 | 1.9 | 32.6 | 36.3 | 2270 |
| 1×120 | 4.5 | 1.8 | 28.6 | 31.4 | 0.45 | 2.0 | 34.6 | 38.5 | 2730 |
| 1×150 | 4.5 | 1.8 | 30.1 | 33.3 | 0.45 | 2.1 | 36.3 | 40.2 | 3020 |
| 1×185 | 4.5 | 1.9 | 32.1 | 35.3 | 0.45 | 2.1 | 38.3 | 42.3 | 3490 |
| 1×240 | 4.5 | 2.0 | 34.8 | 38.2 | 0.45 | 2.2 | 41.2 | 45.7 | 4260 |
| 1×300 | 4.5 | 2.1 | 37.3 | 40.8 | 0.45 | 2.4 | 44.1 | 48.7 | 4810 |
| 1×400 | 4.5 | 2.2 | 40.7 | 44.6 | 0.45 | 2.5 | 47.6 | 52.4 | 6160 |
| 1×500 | 4.5 | 2.4 | 44.1 | 48.2 | 0.45 | 2.6 | 51.3 | 56.6 | 7330 |
| 1×630 | 4.5 | 2.5 | 47.8 | 52.0 | 0.45 | 2.8 | 55.3 | 60.8 | 8800 |
| 3×25 | 4.5 | 2.2 | 43.1 | 47.1 | 0.45 | 2.5 | 50.1 | 55.4 | 3610 |
| 3×35 | 4.5 | 2.3 | 45.2 | 49.2 | 0.45 | 2.6 | 52.3 | 57.7 | 4510 |
| 3×50 | 4.5 | 2.4 | 47.9 | 52.1 | 0.45 | 2.7 | 55.3 | 60.8 | 5210 |
| 3×70 | 4.5 | 2.6 | 52.1 | 56.7 | 0.45 | 2.9 | 59.8 | 65.9 | 6390 |
| 3×95 | 4.5 | 2.7 | 55.9 | 60.7 | 0.45 | 3.0 | 63.8 | 70.1 | 7660 |
| 3×120 | 4.5 | 2.9 | 59.9 | 64.9 | 0.45 | 3.2 | 68.2 | 75.1 | 8810 |
| 3×150 | 4.5 | 3.0 | 63.3 | 68.7 | 0.45 | 3.3 | 71.8 | 78.8 | 10070 |
| 3×185 | 4.5 | 3.2 | 67.6 | 73.2 | 0.45 | 3.5 | 76.5 | 83.7 | 11420 |
Application and Description
These medium voltage elastomeric insulated cables are designed for fixed wiring in ships and on mobile offshore units, suitable for use in power and control applications.
Standards
- BS 6883
- IEC 60332-3A Flame retardant
- IEC 60754-1; IEC 60754- 2 Corrosivity
- IEC 61034-2 Smoke density
Cold bend and impact (-40°C) (on request)
CSA C22.2 No. 38-95 (on request)
Construction
| Parameter | Specification |
|---|---|
| Conductor | Tinned copper wire stranded circular cl. 2 BS 6360/IEC 60228. |
| Conductor Screen | Semiconducting layer or tape. |
| Insulation | HF-EPR GP5 according to BS 7655 1.2. |
| Inner Sheath | Halogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6. |
| Armour | Galvanized steel wire braid or tinned bronze wire braid (single core). |
| Outer Sheath | Halogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6. |
Mechanical and Thermal Properties
Minimum Internal Bending Radius : 12×OD
Temperature Range : -40℃ ~ +90℃
Dimensions and Weight
3.8/6.6kV
| Construction No. of cores×Cross section | Nominal Insulation Thickness | Nominal Inner Sheath Thickness | Minimum Diameter Over Inner Sheath | Maximum Diameter Over Inner Sheath | Nominal Armour Wire Diameter | Nominal Outer Sheath Thickness | Minimum Overall Diameter | Maximum Overall Diameter | Approx. Weight |
|---|---|---|---|---|---|---|---|---|---|
| mm² | mm | mm | mm | mm | mm | mm | mm | mm | kg/km |
| 1×16 | 3.4 | 1.3 | 13.9 | 15.7 | 0.3 | 1.4 | 18.0 | 20.4 | 703 |
| 1×25 | 3.4 | 1.3 | 15.5 | 17.5 | 0.3 | 1.5 | 19.8 | 22.7 | 899 |
| 1×35 | 3.4 | 1.4 | 16.6 | 18.6 | 0.3 | 1.5 | 20.9 | 23.8 | 1029 |
| 1×50 | 3.4 | 1.4 | 17.8 | 19.8 | 0.3 | 1.6 | 22.3 | 25.2 | 1223 |
| 1×70 | 3.4 | 1.5 | 19.7 | 22.1 | 0.3 | 1.7 | 24.4 | 27.4 | 1547 |
| 1×95 | 3.4 | 1.6 | 21.6 | 24.1 | 0.3 | 1.8 | 26.5 | 29.6 | 1903 |
| 1×120 | 3.4 | 1.6 | 23.2 | 25.8 | 0.3 | 1.8 | 28.1 | 31.3 | 2266 |
| 1×150 | 3.4 | 1.7 | 24.9 | 27.6 | 0.45 | 1.9 | 30.7 | 34.4 | 2760 |
| 1×185 | 3.4 | 1.8 | 26.9 | 29.6 | 0.45 | 2.0 | 32.9 | 36.7 | 3282 |
| 1×240 | 3.4 | 1.9 | 29.6 | 32.8 | 0.45 | 2.1 | 35.8 | 39.7 | 4059 |
| 1×300 | 3.4 | 2.0 | 32.1 | 35.4 | 0.45 | 2.2 | 38.5 | 42.9 | 4872 |
| 1×400 | 3.4 | 2.1 | 35.5 | 38.9 | 0.45 | 2.4 | 42.2 | 46.8 | 5844 |
| 1×500 | 3.4 | 2.2 | 38.7 | 42.6 | 0.45 | 2.5 | 45.7 | 50.4 | 7113 |
| 1×630 | 3.4 | 2.4 | 42.6 | 46.6 | 0.45 | 2.7 | 49.9 | 55.2 | 9093 |
| 3×16 | 3.4 | 1.8 | 28.1 | 30.9 | 0.45 | 2.1 | 34.3 | 38.2 | 2109 |
| 3×25 | 3.4 | 2.0 | 31.9 | 35.2 | 0.45 | 2.2 | 38.3 | 42.3 | 2747 |
| 3×35 | 3.4 | 2.0 | 33.8 | 37.1 | 0.45 | 2.3 | 40.4 | 44.9 | 3133 |
| 3×50 | 3.4 | 2.2 | 36.8 | 40.2 | 0.45 | 2.4 | 43.5 | 48.2 | 3772 |
| 3×70 | 3.4 | 2.3 | 40.7 | 44.6 | 0.45 | 2.6 | 47.9 | 52.7 | 4771 |
| 3×95 | 3.4 | 2.5 | 44.7 | 48.8 | 0.45 | 2.8 | 52.3 | 57.7 | 5900 |
| 3×120 | 3.4 | 2.6 | 48.6 | 53.1 | 0.45 | 2.9 | 56.3 | 61.8 | 7098 |
| 3×150 | 3.4 | 2.7 | 51.9 | 56.6 | 0.45 | 3.1 | 60.1 | 66.2 | 8304 |
| 3×185 | 3.4 | 2.9 | 56.2 | 61.1 | 0.45 | 3.2 | 64.6 | 70.8 | 9895 |
| 3×240 | 3.4 | 3.1 | 62.0 | 67.4 | 0.45 | 3.5 | 70.9 | 77.9 | 12358 |
6.6/6.6kV
| Construction No. of cores×Cross section | Nominal Insulation Thickness | Nominal Inner Sheath Thickness | Minimum Diameter Over Inner Sheath | Maximum Diameter Over Inner Sheath | Nominal Armour Wire Diameter | Nominal Outer Sheath Thickness | Minimum Overall Diameter | Maximum Overall Diameter | Approx. Weight |
|---|---|---|---|---|---|---|---|---|---|
| mm² | mm | mm | mm | mm | mm | mm | mm | mm | kg/km |
| 1×25 | 5.5 | 1.5 | 19.9 | 22.4 | 0.3 | 1.7 | 24.6 | 27.7 | 1211 |
| 1×35 | 5.5 | 1.5 | 20.8 | 23.3 | 0.3 | 1.7 | 25.5 | 28.6 | 1338 |
| 1×50 | 5.5 | 1.6 | 22.2 | 24.7 | 0.3 | 1.8 | 27.1 | 30.2 | 1565 |
| 1×70 | 5.5 | 1.7 | 24.1 | 26.7 | 0.45 | 1.9 | 29.9 | 33.6 | 2017 |
| 1×95 | 5.5 | 1.7 | 25.8 | 28.5 | 0.45 | 2.0 | 31.8 | 35.5 | 2383 |
| 1×120 | 5.5 | 1.8 | 27.7 | 30.4 | 0.45 | 2.0 | 33.7 | 37.5 | 2794 |
| 1×150 | 5.5 | 1.9 | 29.3 | 32.5 | 0.45 | 2.1 | 35.5 | 39.4 | 3213 |
| 1×185 | 5.5 | 1.9 | 31.1 | 34.3 | 0.45 | 2.2 | 37.5 | 41.5 | 3737 |
| 1×240 | 5.5 | 2.0 | 33.8 | 37.2 | 0.45 | 2.3 | 40.4 | 44.9 | 4548 |
| 1×300 | 5.5 | 2.1 | 36.4 | 39.8 | 0.45 | 2.4 | 43.1 | 47.7 | 5392 |
| 1×400 | 5.5 | 2.3 | 39.9 | 43.8 | 0.45 | 2.6 | 47.0 | 51.8 | 6384 |
| 1×500 | 5.5 | 2.4 | 43.2 | 47.2 | 0.45 | 2.7 | 50.5 | 55.8 | 7689 |
| 1×630 | 5.5 | 2.5 | 46.8 | 51.0 | 0.45 | 2.8 | 54.3 | 59.8 | 9709 |
| 3×25 | 5.5 | 2.3 | 41.2 | 45.1 | 0.45 | 2.6 | 48.4 | 53.6 | 3746 |
| 3×35 | 5.5 | 2.4 | 43.3 | 47.3 | 0.45 | 2.7 | 50.6 | 55.9 | 4204 |
| 3×50 | 5.5 | 2.5 | 46.1 | 50.2 | 0.45 | 2.8 | 53.6 | 59.0 | 4872 |
| 3×70 | 5.5 | 2.7 | 50.2 | 54.8 | 0.45 | 3.0 | 58.1 | 64.1 | 5992 |
| 3×95 | 5.5 | 2.8 | 54.0 | 58.8 | 0.45 | 3.1 | 62.1 | 68.3 | 7130 |
| 3×120 | 5.5 | 3.0 | 58.0 | 63.0 | 0.45 | 3.3 | 66.5 | 72.9 | 8486 |
| 3×150 | 5.5 | 3.1 | 61.4 | 66.8 | 0.45 | 3.4 | 70.1 | 77.0 | 9723 |
| 3×185 | 5.5 | 3.3 | 65.7 | 71.3 | 0.45 | 3.6 | 74.8 | 81.9 | 11448 |
| 3×240 | 5.5 | 3.5 | 71.5 | 77.6 | 0.45 | 3.9 | 81.2 | 89.0 | 14038 |
6.35/11kV
| Construction No. of cores×Cross section | Nominal Insulation Thickness | Nominal Inner Sheath Thickness | Minimum Diameter Over Inner Sheath | Maximum Diameter Over Inner Sheath | Nominal Armour Wire Diameter | Nominal Outer Sheath Thickness | Minimum Overall Diameter | Maximum Overall Diameter | Approx. Weight |
|---|---|---|---|---|---|---|---|---|---|
| mm² | mm | mm | mm | mm | mm | mm | mm | mm | kg/km |
| 1×35 | 6.5 | 1.6 | 22.9 | 25.5 | 0.3 | 1.8 | 27.8 | 31.0 | 1514 |
| 1×50 | 6.5 | 1.7 | 24.3 | 26.9 | 0.45 | 1.9 | 30.1 | 33.8 | 1751 |
| 1×70 | 6.5 | 1.7 | 26.0 | 28.7 | 0.45 | 2.0 | 32.0 | 35.8 | 2201 |
| 1×95 | 6.5 | 1.8 | 27.9 | 30.7 | 0.45 | 2.1 | 34.1 | 37.9 | 2600 |
| 1×120 | 6.5 | 1.9 | 29.8 | 32.9 | 0.45 | 2.1 | 36.0 | 39.9 | 3021 |
| 1×150 | 6.5 | 1.9 | 31.2 | 34.5 | 0.45 | 2.2 | 37.6 | 41.6 | 3427 |
| 1×185 | 6.5 | 2.0 | 33.3 | 36.5 | 0.45 | 2.3 | 39.8 | 44.3 | 3987 |
| 1×240 | 6.5 | 2.1 | 36.0 | 39.4 | 0.45 | 2.4 | 42.7 | 47.3 | 4814 |
| 1×300 | 6.5 | 2.2 | 38.5 | 42.3 | 0.45 | 2.5 | 45.4 | 50.1 | 5674 |
| 1×400 | 6.5 | 2.4 | 42.0 | 46.0 | 0.45 | 2.6 | 49.2 | 54.4 | 6637 |
| 1×500 | 6.5 | 2.5 | 45.3 | 49.4 | 0.45 | 2.8 | 52.8 | 58.2 | 7986 |
| 1×630 | 6.5 | 2.6 | 48.9 | 53.5 | 0.45 | 2.9 | 56.6 | 62.2 | 10057 |
| 3×35 | 6.5 | 2.6 | 47.8 | 52.0 | 0.45 | 2.9 | 55.5 | 61.1 | 4793 |
| 3×50 | 6.5 | 2.7 | 50.6 | 55.2 | 0.45 | 3.0 | 58.5 | 64.6 | 5489 |
| 3×70 | 6.5 | 2.8 | 54.5 | 59.3 | 0.45 | 3.2 | 62.8 | 69.0 | 6612 |
| 3×95 | 6.5 | 3.0 | 58.6 | 63.5 | 0.45 | 3.3 | 67.0 | 73.4 | 7829 |
| 3×120 | 6.5 | 3.1 | 62.4 | 67.8 | 0.45 | 3.5 | 71.3 | 78.2 | 9182 |
| 3×150 | 6.5 | 3.3 | 66.0 | 71.5 | 0.45 | 3.6 | 75.0 | 82.2 | 10498 |
| 3×185 | 6.5 | 3.4 | 70.1 | 76.1 | 0.45 | 3.8 | 79.5 | 87.2 | 12218 |
Certificate Display
Type and routine tests are issued from our own testing centre under the ISO 9001 quality system — test reports and certificates accompany every shipment.
Factory Tour
Why Choose Us
Packing & Shipping
- Wooden, steel or steel-wood drums; drum length to customer requirement
- Drum marking per customer / utility specification
- Both drum ends sealed and protected for sea freight
Ready for Your Next Cable Project?
Send us your specifications, cable schedule or RFQ — our engineering team replies with a technical proposal and price within one working day.
- Emailinfo@qzcablegroup.com
- WhatsApp / WeChat+86 173 3570 4553
- Contact personChloe · Export Department
- Factory addressWest Industrial Park, Zhulin Town, Gongyi City, Henan Province, China