600V — Type TC Instrumentation Cable
600V UL Type TC Instrumentation Cable,Single & Multiple Twisted Pairs,Multiple Pairs or Triads Cable
Product Description
600V UL Type TC Instrumentation Cable,Single & Multiple Twisted Pairs,Multiple Pairs or Triads Cable
600V Instrumentation Cable
Application
For use in instrumentation and process control applications where superior protection from electrostatic interference is required. UL listed as Type TC and approved for installation indoors or outdoors, aerially, in conduits, ducts, cable trays and direct burial in circuits not exceeding 600 volts. May be used in NEC Class 1, Division 2 hazardous locations. UL approved for NEC continuous operation at 75°C in wet locations, 90°C in dry locations, 130°C for emergency overload conditions, and 250°C for short circuit conditions.
| 600 Volt UL Type TC, 90°C; Multiple Pairs; Overall Shield; TFN PVC/Nylon Insulation & PVC Jacket; Copper Conductors | |
| 600 Volt UL Type TC, 90°C; Single & Multiple Twisted Pairs; Individual & Overall Shield; TFN PVC/Nylon Insulation & PVC Jacket; Copper Conductors | |
| 600 Volt UL Type TC, 90°C; Multiple Pairs; Individual & Overall Shield; THHN or THWN Insulation & PVC Jacket; Copper Conductors | |
| 600 Volt UL Type TC-ER, 90°C; Single and Multiple Triads; Individual & Overall Shield; TFN PVC/Nylon Insulation & PVC Jacket; Copper Conductors | |
| 600 Volt UL Type TC, 90°C; Multiple Conductor; Overall Shield; FR-EP Insulation & CPE Jacket; Tinned Copper Conductors, Flame-retardant Instrumentation cable | |
| 600 Volt UL Type TC-ER, 90°C; Multiple Pairs; Individual & Overall Shield; FR-EP Insulation & CPE Jacket; Tinned Copper Conductors, Flame-retardant Instrumentation cable | |
| 600 Volt UL Type TC-LS, 90°C; Single & Multiple Pairs; Individual & Overall Shield; XLP Insulation; Low Smoke Zero Halogen Jacket; Tinned Copper Conductors FM Approved, Low Smoke Zero Halogen Instrumentation cable | |
| 600 Volt UL Type TC-LS, 90°C; Single & Multiple Triads; Individual & Overall Shield; XLP Insulation; Low Smoke Zero Halogen Jacket; Tinned Copper Conductors; FM Approved, Low Smoke Zero Halogen Instrumentation cable |
600V Multiple Pairs – TFN PVC/Nylon, PVC, O/S
| Size AWG | Number of Pairs | Insulation Thickness Mils | Nylon Covering Thickness Mils | Jacket Thickness Mils | Overall Diameter Inches | Net Weight Lbs/Mft |
| 18 | 2 | 15 | 4 | 45 | 0.41 | 70 |
| 18 | 4 | 15 | 4 | 45 | 0.49 | 118 |
| 18 | 8 | 15 | 4 | 60 | 0.65 | 212 |
| 18 | 12 | 15 | 4 | 60 | 0.76 | 302 |
| 18 | 16 | 15 | 4 | 80 | 0.89 | 374 |
| 18 | 24 | 15 | 4 | 80 | 1.03 | 572 |
| 18 | 36 | 15 | 4 | 80 | 1.18 | 796 |
| 18 | 50 | 15 | 4 | 80 | 1.44 | 1046 |
| 16 | 2 | 15 | 4 | 45 | 0.45 | 89 |
| 16 | 3 | 15 | 4 | 45 | 0.52 | 121 |
| 16 | 4 | 15 | 4 | 45 | 0.57 | 150 |
| 16 | 8 | 15 | 4 | 60 | 0.75 | 283 |
| 16 | 12 | 15 | 4 | 60 | 0.88 | 389 |
| 16 | 16 | 15 | 4 | 80 | 1.03 | 540 |
| 16 | 24 | 15 | 4 | 80 | 1.21 | 742 |
| 16 | 36 | 15 | 4 | 80 | 1.4 | 1038 |
| 16 | 50 | 15 | 4 | 80 | 1.61 | 1436 |
600V Single & Multiple Twisted Pairs – TFN PVC/Nylon, PVC, I/S & O/S
| Size AWG | Number of Pairs | Insulation Thickness Mils | Nylon Covering Thickness Mils | Jacket Thickness Mils | Overall Diameter Inches | Net Weight Lbs/Mft |
| 18 | 1 | 15 | 4 | 45 | 0.27 | 42 |
| 18 | 2 | 15 | 4 | 45 | 0.44 | 82 |
| 18 | 4 | 15 | 4 | 45 | 0.52 | 146 |
| 18 | 8 | 15 | 4 | 60 | 0.71 | 279 |
| 18 | 12 | 15 | 4 | 60 | 0.85 | 391 |
| 18 | 16 | 15 | 4 | 80 | 1.05 | 494 |
| 18 | 24 | 15 | 4 | 80 | 1.2 | 752 |
| 18 | 36 | 15 | 4 | 80 | 1.37 | 1053 |
| 18 | 50 | 15 | 4 | 80 | 1.71 | 1300 |
| 16 | 1 | 15 | 4 | 45 | 0.29 | 55 |
| 16 | 2 | 15 | 4 | 45 | 0.48 | 105 |
| 16 | 3 | 15 | 4 | 45 | 0.56 | 136 |
| 16 | 4 | 15 | 4 | 60 | 0.63 | 207 |
| 16 | 6 | 15 | 4 | 60 | 0.77 | 257 |
| 16 | 8 | 15 | 4 | 60 | 0.81 | 349 |
| 16 | 12 | 15 | 4 | 80 | 1.11 | 528 |
| 16 | 16 | 15 | 4 | 80 | 1.16 | 623 |
| 16 | 24 | 15 | 4 | 80 | 1.39 | 944 |
| 16 | 36 | 15 | 4 | 80 | 1.59 | 1331 |
| 16 | 50 | 15 | 4 | 110 | 1.96 | 1731 |
600V Multiple Pairs – THHN PVC/Nylon, PVC, I/S & O/S
| Size AWG | Number of Pairs | Insulation Thickness Mils | Nylon Covering Thickness Mils | Jacket Thickness Mils | Overall Diameter Inches | Net Weight Lbs/Mft |
| 14 | 2 | 15 | 4 | 45 | 0.57 | 156 |
| 14 | 4 | 15 | 4 | 60 | 0.73 | 285 |
| 14 | 8 | 15 | 4 | 60 | 0.93 | 520 |
| 14 | 12 | 15 | 4 | 80 | 1.16 | 788 |
| 14 | 16 | 15 | 4 | 80 | ||
| 14 | 24 | 15 | 4 | 80 | 1.58 | 1445 |
600V Multiple Triads – TFN PVC/Nylon, PVC, I/S & O/S
| Size AWG | Number of Triads | Insulation Thickness Mils | Nylon Covering Thickness Mils | Jacket Thickness Mils | Overall Diameter Inches | Net Weight Lbs/Mft |
| 18 | 1 | 15 | 4 | 45 | 0.29 | 52 |
| 18 | 4 | 15 | 4 | 60 | 0.61 | 207 |
| 18 | 8 | 15 | 4 | 60 | 0.78 | 355 |
| 18 | 12 | 15 | 4 | 80 | 0.98 | 538 |
| 18 | 24 | 15 | 4 | 80 | 1.33 | 971 |
| 16 | 1 | 15 | 4 | 45 | 0.31 | 55 |
| 16 | 4 | 15 | 4 | 60 | 0.67 | 233 |
| 16 | 8 | 15 | 4 | 60 | 0.9 | 401 |
| 16 | 12 | 15 | 4 | 80 | 1.08 | 607 |
| 16 | 16 | 15 | 4 | 80 | 1.27 | 838 |
| 16 | 24 | 15 | 4 | 80 | 1.48 | 1100 |
600V Multiple Conductor – FR-EP, CPE, O/S
| Size AWG | Number of Conductors | Insulation Thickness Mils | Jacket Thickness Mils | Overall Diameter Inches | Net Weight Lbs/Mft |
| 18 | 2 | 25 | 45 | 0.3 | 42 |
| 18 | 3 | 25 | 45 | 0.31 | 53 |
| 16 | 2 | 25 | 45 | 0.32 | 52 |
| 16 | 3 | 25 | 45 | 0.34 | 66 |
| 16 | 4 | 25 | 45 | 0.37 | 80 |
600V Multiple Pairs or Triads – FR-EP, CPE, I/S & O/S
| Size AWG | Number of Pairs | Insulation Thickness Mils | Jacket Thickness Mils | Overall Diameter Inches | Net Weight Lbs/Mft |
| 18 | 2 | 25 | 45 | 0.48 | 90 |
| 18 | 4 | 25 | 60 | 0.59 | 165 |
| 18 | 8 | 25 | 60 | 0.75 | 280 |
| 18 | 12 | 25 | 80 | 0.93 | 430 |
| 18 | 16 | 25 | 80 | 1.05 | 540 |
| 18 | 24 | 25 | 80 | 1.24 | 760 |
600V Single or Multiple Pairs – XLP, LSZH, I/S & O/S
| Size AWG | Number of Pairs | Insulation Thickness Mils | Jacket Thickness Mils | Overall Diameter Inches | Net Weight Lbs/Mft |
| 16 | 1 | 30 | 60 | 0.33 | 59 |
| 16 | 2 | 30 | 60 | 0.58 | 136 |
| 16 | 4 | 30 | 60 | 0.67 | 216 |
| 16 | 8 | 30 | 60 | 0.9 | 397 |
| 16 | 12 | 30 | 80 | 1.04 | 530 |
| 16 | 24 | 30 | 80 | 1.4 | 960 |
600V Single or Multiple Triads – XLP, LSZH, I/S & O/S
| Size AWG | Number of Triads | Insulation Thickness Mils | Jacket Thickness Mils | Overall Diameter Inches | Net Weight Lbs/Mft |
| 16 | 1 | 30 | 60 | 0.35 | 67 |
| 16 | 2 | 30 | 60 | 0.64 | 170 |
| 16 | 4 | 30 | 60 | 0.74 | 268 |
| 16 | 6 | 30 | 60 | 0.93 | 422 |
| 16 | 8 | 30 | 80 | 0.96 | 500 |
| 16 | 12 | 30 | 80 | 1.14 | 705 |
Certificate Display
Type and routine tests are issued from our own testing centre under the ISO 9001 quality system — test reports and certificates accompany every shipment.
Factory Tour
Why Choose Us
Packing & Shipping
- Wooden, steel or steel-wood drums; drum length to customer requirement
- Drum marking per customer / utility specification
- Both drum ends sealed and protected for sea freight
Ready for Your Next Cable Project?
Send us your specifications, cable schedule or RFQ — our engineering team replies with a technical proposal and price within one working day.
- Emailinfo@qzcablegroup.com
- WhatsApp / WeChat+86 173 3570 4553
- Contact personChloe · Export Department
- Factory addressWest Industrial Park, Zhulin Town, Gongyi City, Henan Province, China
Related products
Related solutions
Power Distribution Cable Solutions
Qingzhou Cable provides low- and medium-voltage cable solutions for electrical distribution networks, supporting power delivery from substations to commercial, industrial and residential users.
Power Substation Cable Solutions
Solar & Renewable Energy Cable Solutions
Building & Infrastructure Cable Solutions
Mining Cable Solutions