One-stop Solution for Wire & Cable · Since 1969
Type MC Armored Cables
Building Wire

Type MC Armored Cables

  • UL Listed as MC.
  • Single conductors are dual rated THHN/THWN-2, meeting 90 °C in Wet and Dry Locations.
  • All Singles meet the VW-1 flame test.

Product Description

Type MC-HCF-AIA

Features

UL Listed as MC.

Single conductors are dual rated THHN/THWN-2, meeting 90 °C in Wet and Dry Locations.

All Singles meet the VW-1 flame test.

Insulation is rated Gas and Oil resistant II.

Cables is rated for CT use. RoHS-2 Compliant.

Listed for use in UL 1, 2 and 3 Hour Through Penetration

Firestop Systems C-AJ-310,

C-AJ-3111, C-AJ-3112, W-L-3077, W-L-3078.

For ease of pulling and

installation, the cable is reverse wound on reel. For coils, pull

from inside end to ensure ease of installation.

Application

For installations requiring

redundant, dedicated or isolated grounding paths.

Health Care Facilities: For branch

Per NEC 300.22(C), in

1

2

3

4

5

environmental air-handling spaces.

Class I Div. 2, Class II Div. 2, and Class III Div. 1 hazardous locations, in accordance with NEC.

2. Insulation Circuit & Ground:

Flame retardant thermoplastic polyvinyl chloride (PVC) and nylon covering.

Conductor’s and Ground ID:

Requires use of UL Listed MC-HCF-AIA fittings.

Bui lding Wire

Standards

UL 1569 Metal Clad cables.

UL 83 Thermoplastic-Insulated Wires and Cables.

UL 1685 Vertical-Tray Fire-

Propagation and Smoke-Release Test for Electrical and Optical- Fiber Cables.

480Y / 277V

# Cdr.

Color Code

Ground

Al Bond

2

BN

GY

GN

Bare

2

OE

GY

GN

Bare

2

YW

GY

GN

Bare

2

PE

GY

GN

Bare

3

BN

OE

GY

GN

Bare

3

OE

YW

GY

GN

Bare

3

BN

YW

GY

GN

Bare

3

YW

PE

GY

GN

Bare

BN

PE

GY

GN

Bare

Federal Specification A-A-59544 (formerly J-C-30B).

ICEA S-95-658/NEMA WC70 (as applicable)

Specifications

Maximum operating voltage:

  • 600 volts
  • circuit wiring in patient care
  • areas of hospitals, medical

centers, nursing homes, dental offices, clinics, outpatient

facilities and other health care facilities in accordance with

NEC articles 517, 330 and 300.4 as applicable. (Note: Use in

hazardous anesthetizing areas is not permitted.)

For places of assemblies and

theaters per NEC articles 518 and

520, respectively.

In cable tray and approved raceways.

Maximum conductor operation temperatures:

3. Assembly: All insulated

conductors, phases and

grounding, are individually

wrapped in a binder tape and twisted together.

4. Bare aluminum grounding/

bonding conductor: It is located outside the individually wrapped assembly of other conductors and in contact with the

interlocked aluminum armor.

5. Armor: Easy to identify green color aluminum interlocked

armor. It is applied over the

assembly of conductors, tape and in contact with aluminum grounding/bonding conductor.

• 90 °C Dry

Engineering Information

1. Conductor: Soft annealed uncoated copper solid wire

per ASTM B3, or soft annealed uncoated copper Class B or C concentric stranding or unilay (19 wires) per ASTM B8, or

combination unilay per ASTM B787.

Sizes: 14 AWG up to 10 AWG.

Number of Conductors: 2 to 3.

In dry locations and embedded in plaster finish on brick or other masonry, except in damp or wet locations.

Type MC/RG & MC/RG-HCF-AIA Al Bonding Wire in Contact with Armor, 90 °C

Technical Data

600 V Copper PVC/Nylon, Green Insulated Ground, Aluminum Bonding Wire in Contact with Armor, 90 °C

Conductor

Grounding Wire

Nominal O.D.

Mass

Size

AWG / # Conductors

Conductor

Color

Insulated Ground

(Green)

Solid

Aluminum

Bonding Ground

in

lb/kft

Solid Copper Conductors with Solid Aluminum Bonding Ground Conductor 120/208 V

14-2

BK/WE

14

12

0.542

111

14-3

BK/WE/RD

14

12

0.552

130

12-2

BK/WE

12

10

0.563

140

12-2

RD/WE

12

10

0.563

140

12-2

BE/WE

12

10

0.563

140

12-3

BK/WE/RD

12

10

0.590

155

10-2

BK/WE

10

8

0.645

181

10-2

RD/WE

10

8

0.645

181

10-2

BE/WE

10

8

0.645

181

10-3

BK/WE/RD

10

8

0.685

218

Stranded Copper Conductors with Solid Aluminum Bonding Ground Conductor, 120/208 V

12-2

BK/WE

12

10

0.585

147

12-2

RD/WE

12

10

0.585

147

12-2

BE/WE

12

10

0.585

147

12-3

BK/WE/RD

12

10

0.621

176

10-2

RD/WE

10

8

0.687

206

10-3

RD/WE/RD

10

8

0.728

251

Multiple Neutrals: Solid copper conductors with solid aluminum bonding ground conductors

12-2

12-2

BK/RD

WE-BK/WE-RD

12

10

0.563

140

12-3

12-3

BK/WE/RD

WE-BK/WE-RD/WE-BE

12

10

0.590

155

10-2

10-2

BK/RD

WE-BK/WE-RD

10

8

0.645

181

10-3

10-3

BK/WE/RD

WE-BK/WE-RD/WE-BE

10

8

0.685

218

Multiple Neutrals: Stranded Copper Conductors with Solid Aluminum Bonding Ground Conductor

12-2

12-2

BK/RD

WE-BK/WE-RD

12

10

0.585

147

The above data are approximate and subject to normal manufacturing tolerances. Where required, the compatibility with glands, connectors, and accessories should be verified using the actual dimensions of the product. Other sizes are available upon request.

Capacities: Refer to the beginning of the section.

Color Abbreviations

Black

White

Brown

Orange

Yellow

Purple

Grey

Green

BK

WE

BN

OE

YW

PE

GY

GN

Certificate Display

ISO 9001 Quality Management System
ISO 9001 Certificate (2025–2028)
ISO 9001 Certificate (NOA)
CE — Verification of Conformity
RoHS Compliance Attestation (EU)
Low Voltage Directive Attestation (EU)

Type and routine tests are issued from our own testing centre under the ISO 9001 quality system — test reports and certificates accompany every shipment.

Factory Tour

Why Choose Us

50+ years of experience Trusted manufacturing expertise since 1969
International standards IEC, ASTM, BS, CSA and other global standards
Strict quality control Comprehensive testing throughout production
Large production capacity Reliable supply for utility and EPC projects
Fast global delivery Efficient manufacturing and worldwide shipping
Technical support Expert assistance from inquiry to project completion

Packing & Shipping

  • Wooden, steel or steel-wood drums; drum length to customer requirement
  • Drum marking per customer / utility specification
  • Both drum ends sealed and protected for sea freight
Get in touch

Ready for Your Next Cable Project?

Send us your specifications, cable schedule or RFQ — our engineering team replies with a technical proposal and price within one working day.

  • Emailinfo@qzcablegroup.com
  • WhatsApp / WeChat+86 173 3570 4553
  • Contact personChloe · Export Department
  • Factory addressWest Industrial Park, Zhulin Town, Gongyi City, Henan Province, China

    The more specific the standard and size, the faster we can quote.
    Inquiry WhatsApp Email